A Flow System for Generation of Concentration Perturbation in Two-Dimensional Correlation Near-Infrared Spectroscopy: Application to Variable Selection in Multivariate Calibration

被引:7
|
作者
Pereira, Claudete Fernandes [1 ]
Pasquini, Celio [2 ]
机构
[1] Univ Fed Paraiba, Dept Quim, BR-58051970 Joao Pessoa, Paraiba, Brazil
[2] Univ Estadual Campinas, Dept Analyt Chem, Inst Chem, BR-13084971 Campinas, SP, Brazil
关键词
Flow system perturbation; Two-dimensional correlation spectra; 2D-COS; Near-infrared spectroscopy; Gasoline; Variable selection; Multivariate calibration; REFLECTION/INFRARED CORRELATION SPECTROSCOPY; FOURIER-TRANSFORM RAMAN; SPECTRAL VARIATIONS; BAND-ASSIGNMENT; LACTOGLOBULIN; ADSORPTION; PROTEIN;
D O I
10.1366/000370210791211772
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A flow system is proposed to produce a concentration perturbation in liquid samples, aiming at the generation of two-dimensional correlation near-infrared spectra. The system presents advantages in relation to batch systems employed for the same purpose: the experiments are accomplished in a closed system; application of perturbation is rapid and easy; and the experiments can be carried out with micro-scale volumes. The perturbation system has been evaluated in the investigation and selection of relevant variables for multivariate calibration models for the determination of quality parameters of gasoline, including ethanol content, MON (motor octane number), and RON (research octane number). The main advantage of this variable selection approach is the direct association between spectral features and chemical composition, allowing easy interpretation of the regression models.
引用
收藏
页码:507 / 513
页数:7
相关论文
共 50 条
  • [31] Visual Recognition of Fishmeal and Meat and Bone Meal Using Temperature-Dependent Two-Dimensional Correlation Near-Infrared Spectroscopy
    Lu, Chengxu
    Chen, Longjian
    Yang, Zengling
    Liu, Xian
    Han, Lujia
    APPLIED SPECTROSCOPY, 2013, 67 (12) : 1390 - 1394
  • [32] Net analyte signal based two-dimensional (NAS 2D) correlation near infrared spectroscopy
    Geng, Ying
    Xiang, Bingren
    JOURNAL OF MOLECULAR STRUCTURE, 2010, 974 (1-3) : 173 - 178
  • [33] Two-Dimensional Heterospectral Correlation Analysis of Water and Liquid Oleic Acid Using an Online Near-Infrared/Mid-Infrared Dual-Region Spectrometer
    Genkawa, Takuma
    Watari, Masahiro
    Nishii, Takashi
    Suzuki, Masao
    Ozaki, Yukihiro
    APPLIED SPECTROSCOPY, 2013, 67 (07) : 724 - 730
  • [34] Two-Dimensional Correlation Near Infrared Spectroscopy Analysis of Sodium Silicate and Vinyl Triethoxy Silane
    Fu Xiao-hui
    Zhang Wen-bo
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (03) : 782 - 786
  • [35] Study of the similarity between distribution maps of concentration in near-infrared spectroscopy chemical imaging obtained by different multivariate calibration approaches
    Sabin, Guilherme Post
    de Carvalho Rocha, Werickson Fortunato
    Poppi, Ronei Jesus
    MICROCHEMICAL JOURNAL, 2011, 99 (02) : 542 - 547
  • [36] A novel approach for development of a multivariate calibration model using a Doehlert experimental design: Application for prediction of key gasoline properties by Near-infrared Spectroscopy
    Reboucas, Marcio V.
    Santos, Jamile B.
    Pimentel, Maria Fernanda
    Teixeira, Leonardo S. G.
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2011, 107 (01) : 185 - 193
  • [37] Analysis of the Effect of Moisture on Soil Spectra Detection by Using Two-Dimensional Correlation Near Infrared Spectroscopy
    Song Hai-yan
    Cheng Xu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (05) : 1240 - 1243
  • [38] Detection of Aspartic Acid in Fermented Cordyceps Powder Using Near Infrared Spectroscopy Based on Variable Selection Algorithms and Multivariate Calibration Methods
    Chu Zhang
    Ning Xu
    Liubin Luo
    Fei Liu
    Wenwen Kong
    Lei Feng
    Yong He
    Food and Bioprocess Technology, 2014, 7 : 598 - 604
  • [39] Near-infrared spectroscopy quantitative determination of Pefloxacin mesylate concentration in pharmaceuticals by using partial least squares and principal component regression multivariate calibration
    Xie, Yunfei
    Song, Yan
    Zhang, Yong
    Zhao, Bing
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2010, 75 (05) : 1535 - 1539
  • [40] Multivariate calibration for near-infrared spectroscopic assays of blood substrates in human plasma based on variable selection using PLS-regression vector choices
    H. M. Heise
    A. Bittner
    Fresenius' Journal of Analytical Chemistry, 1998, 362 : 141 - 147