Determination of biogenic amines in tomato by ion-pair chromatography coupled to an amine-selective potentiometric detector

被引:11
作者
Gil, Renato L. [1 ]
Amorim, Celia G. [1 ]
Montenegro, Maria C. B. S. M. [1 ]
Araujo, Alberto N. [1 ]
机构
[1] Univ Porto, Fac Farm, Dept Ciencias Quim, LAQV REQUIMTE, R Jorge Viterbo Ferreira 228, P-4050313 Porto, Portugal
关键词
Food analysis; Biogenic amines; Ion-pair chromatography; Potentiometry; Ion-selective electrodes; PERFORMANCE LIQUID-CHROMATOGRAPHY; INJECTION-ANALYSIS; BIOACTIVE AMINES; ORGANIC-ACIDS; MEAT; VALIDATION; CHEESE; ANIONS; FOOD;
D O I
10.1016/j.electacta.2021.138134
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
It is described the determination of underivatized biogenic amines by ion-pair chromatography coupled to potentiometric detection, for food quality control. A wall-jet flow-cell was used to hold an amine-selective electrode, based on cucurbit[6]uril as an ionophore, and a commercial reference electrode. The biogenic amines were separated in less than 20 min using a C18 column as the stationary phase. This method comprises a gradient elution with a mobile phase containing lithium formate buffer, acetonitrile, and butane-sulfonic acid sodium salt as an ion-pair agent. The proposed method was validated following the International Council for harmonization guidelines. Calibration data fitted a linear regression model with R-2 varying from 0.9804 to 0.9972. Repeatability intra and inter-day showed relative standard deviation values lower than 9.1% and 13.3%, respectively. Detection and quantification limits ranged from 0.03 to 0.20 mg L-1 and 0.09 to 0.61 mg L-1 , respectively. Spiked tomato samples were analysed to assess the accuracy, yielding recovery values from 85.8 to 108.5%. The biogenic amines content in fresh tomatoes, canned chopped tomato, and pulp tomato was 7.11, 5.12, and 7.69 mg L-1, respectively. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:9
相关论文
共 61 条
[1]   POTENTIOMETRIC DETECTION IN ION CHROMATOGRAPHY USING A METALLIC COPPER INDICATOR ELECTRODE [J].
ALEXANDER, PW ;
HADDAD, PR ;
TROJANOWICZ, M .
CHROMATOGRAPHIA, 1985, 20 (03) :179-184
[2]   Exploiting sequential injection analysis with lab-on-valve and miniaturized potentiometric detection - Epinephrine determination in pharmaceutical products [J].
Amorim, C. G. ;
Araujo, A. N. ;
Montenegro, M. C. B. S. M. .
TALANTA, 2007, 72 (04) :1255-1260
[3]   Fast and selective method for biogenic amines determination in wines and beers by ultra high-performance liquid chromatography [J].
Angulo, Maria Fernanda ;
Flores, Mauricio ;
Aranda, Mario ;
Henriquez-Aedo, Karem .
FOOD CHEMISTRY, 2020, 309
[4]  
[Anonymous], 2019, Fish and fishery products. Hazards and controls guidance, V4th
[5]  
[Anonymous], 2020, CHEM PHYS PROPERTIES
[6]   Ion-pair HPLC determination of biogenic amines and precursor aminoacids.: Application of a method based on simultaneous use of heptanesulphonate and octylamine to some foods [J].
Arlorio, M ;
Coïsson, JD ;
Martelli, A .
CHROMATOGRAPHIA, 1998, 48 (11-12) :763-769
[7]   Trace analysis of amines in cheese serum with liquid chromatographic potentiometric detection by using amine-selective electrode [J].
Aydin, Rukiye ;
Asan, Adem ;
Attar, Azade ;
Isildak, Ibrahim .
ARABIAN JOURNAL OF CHEMISTRY, 2019, 12 (08) :4533-4540
[8]   Cucurbituril-Based Molecular Recognition [J].
Barrow, Steven J. ;
Kasera, Setu ;
Rowland, Matthew J. ;
del Barrio, Jesus ;
Scherman, Oren A. .
CHEMICAL REVIEWS, 2015, 115 (22) :12320-12406
[9]   EFFECT OF THE TYPE OF ION-PAIRING REAGENT IN REVERSED-PHASE ION-PAIR CHROMATOGRAPHY [J].
BARTHA, A ;
VIGH, G ;
BILLIET, H ;
DEGALAN, L .
CHROMATOGRAPHIA, 1985, 20 (10) :587-590
[10]   Potentiometric detection of exogenic beta-adrenergic substances in liquid chromatography [J].
Bazylak, G ;
Nagels, LJ .
JOURNAL OF CHROMATOGRAPHY A, 2002, 973 (1-2) :85-96