Validation of different bioimpedance analyzers for predicting cell mass against whole-body counting of potassium (40K) as a reference method

被引:30
作者
Dittmar, M
Reber, H
机构
[1] Univ Mainz, Dept Biol, Inst Anthropol, D-55099 Mainz, Germany
[2] Gutenberg Univ Hosp, Dept Nucl Med, D-55101 Mainz, Germany
关键词
D O I
10.1002/ajhb.20078
中图分类号
Q98 [人类学];
学科分类号
030303 ;
摘要
This study compared two different tetrapolar bioimpedance (BIA) devices for estimating body cell mass (BCM), validated them against whole-body counting of K-40 (TBK method), and developed improved prediction equations for estimating BCM from BIA. In 50 healthy volunteers (age 23-65 years, BMI 18.6-27.7 kg/m(2)), BCM was estimated with the BIA devices Nutriguard-M (Data Input, Germany) and Soft-Tissue-Analyzer-STA (Akern, Italy) and by the TBK method. Methods were compared by the Bland-Altman procedure. New prediction equations for BCM were developed by multiple stepwise regression analysis based on a single BIA parallel model. The Akern device gives similar mean estimates of BCM compared to the Data Input device in males (33.5 vs. 33.3 kg, P = 0.789), but higher values in females (24.6 vs. 22.8 kg; P < 0.001). Both BIA devices overestimate mean BCM relative to the TBK method; in males by 5.0 kg (Data Input, P < 0.001) and 5.1 kg (Akern, P < 0.001); in females by 2.3 kg (Data Input, P < 0.001) and 4.1 kg (Akern, P < 0.001). Limits of agreement between BIA and TBK methods are for males +/-4.99 kg (Data Input) and +/-7.16 kg (Akern); for females, +/-4.69 kg (Data Input) and +/-4.12 kg (Akern). New equations were developed for estimating BCM for both BIA analyzers (Data Input, R-2 = 0.91, SEE = 1.46 kg; Akern, R-2 = 0.90, SEE = 1.48 kg). Since estimates of BCM by the present BIA devices do not differ in males, they might be interchangeable. This does not hold true for females. Because both BIA devices overestimate BCM, the newly developed device-specific equations which reduce bias and limits of agreement should be applied. Am. J. Hum. Biol. 16:697-703, 2004. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:697 / 703
页数:7
相关论文
共 26 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   ELDERLY WOMEN ACCOMMODATE TO A LOW-PROTEIN DIET WITH LOSSES OF BODY CELL MASS, MUSCLE FUNCTION, AND IMMUNE-RESPONSE [J].
CASTANEDA, C ;
CHARNLEY, JM ;
EVANS, WJ ;
CRIM, MC .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 62 (01) :30-39
[3]  
De Lorenzo A, 2000, ANN NY ACAD SCI, V904, P259
[4]   Predicting body cell mass with bioimpedance by using theoretical methods: A technological review [J].
DeLorenzo, A ;
Andreoli, A ;
Matthie, J ;
Withers, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 82 (05) :1542-1558
[5]   Reliability and variability of bioimpedance measures in normal adults: Effects of age, gender, and body mass [J].
Dittmar, M .
AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2003, 122 (04) :361-370
[6]   New equations for estimating body cell mass from bioimpedance parallel models in healthy older Germans [J].
Dittmar, M ;
Reber, H .
AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2001, 281 (05) :E1005-E1014
[7]   New techniques in nutritional assessment: body composition methods [J].
Elia, M ;
Ward, LC .
PROCEEDINGS OF THE NUTRITION SOCIETY, 1999, 58 (01) :33-38
[8]  
Forbes GB., 1987, HUMAN BODY COMPOSITI, DOI DOI 10.1542/peds.2010-3856
[9]  
GRAVES J E, 1989, American Journal of Human Biology, V1, P603, DOI 10.1002/ajhb.1310010511
[10]   Single- and multifrequency models for bioelectrical impedance analysis of body water compartments [J].
Gudivaka, R ;
Schoeller, DA ;
Kushner, RF ;
Bolt, MJG .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 87 (03) :1087-1096