Simultaneous sampling of peroxyacetic acid and hydrogen peroxide in workplace atmospheres

被引:19
作者
Hecht, G [1 ]
Héry, M [1 ]
Hubert, G [1 ]
Subra, I [1 ]
机构
[1] Inst Natl Rech & Secur, F-54501 Vandoeuvre Les Nancy, France
关键词
peracetic acid; hydrogen peroxide; simultaneous sampling;
D O I
10.1093/annhyg/meh067
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The use of peroxyacetic acid (PAA) in the disinfection processes in the food industry or for medical purposes is increasing. As it is the product of the reaction of acetic acid (AA) and hydrogen peroxide (HP) and coexists with them, and given the fact that the chemical properties of these two substances are not very different from PAA, the sampling and analysis of this substance in working atmospheres is difficult. A specific sampling device was developed. It is composed of: (i) a cassette with quartz fibre filters impregnated with titanium oxysulfate hydrate for the sampling of HP followed by; (ii) a tube filled with silica gel soaked with methyl p-tolylsulfoxide for the sampling of PAA. The analysis of this silica gel was performed by liquid chromatography with UV detection of the methyl p-sulfone generated by the sampling of PAA. The conservation of the sampling media (before and after sampling) and its efficiency were also checked. From the results of sampling campaigns performed in various workplaces, the relative contributions of PAA, AA and HP to an exposure index, taking into account the atmospheric concentrations and the threshold limit values, were established. This calculation shows that the simultaneous determination of PAA and HP, which the method presented in this paper allows, provides a fairly good estimation of the exposure.
引用
收藏
页码:715 / 721
页数:7
相关论文
共 12 条
[1]  
American Conference of Governmental Industrial Hygienists (ACGIH) Worldwide, 2002, THRESH LIM VAL CHEM
[2]   Determination of hydrogen peroxide in workplace air: interferences and method validation [J].
Christensen, CS ;
Brodsgaard, S ;
Mortensen, P ;
Egmose, K ;
Linde, SA .
JOURNAL OF ENVIRONMENTAL MONITORING, 2000, 2 (04) :339-343
[3]  
DIFURIA F, 1988, ANALYST, V113, P793
[4]  
*ECETOC, 40 ECETOC
[5]   Determination of gas phase peroxyacetic acid using pre-column derivatization with organic sulfide reagents and liquid chromatography [J].
Effkemann, S ;
Brodsgaard, S ;
Mortensen, P ;
Linde, SA ;
Karst, U .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (02) :551-561
[6]   Sensory irritation of acetic acid, hydrogen peroxide, peroxyacetic acid and their mixture in mice [J].
Gagnaire, F ;
Marignac, B ;
Hecht, G ;
Héry, M .
ANNALS OF OCCUPATIONAL HYGIENE, 2002, 46 (01) :97-102
[7]   Workplace monitoring of hydrogen peroxide using titanyl-coated sorbents [J].
Hecht, G ;
Aubert, S ;
Gerardin, F ;
Hery, M .
JOURNAL OF ENVIRONMENTAL MONITORING, 1999, 1 (02) :149-152
[8]   Generation of controlled atmospheres for the determination of the irritant potency of peroxyacetic acid [J].
Hecht, G ;
Héry, M .
ANNALS OF OCCUPATIONAL HYGIENE, 2002, 46 (01) :89-96
[9]  
*HLTH SAF EX, 2002, EH402002 HLTH SAF EX
[10]  
NIOSH, 1994, 1603 NIOSH