Improving visualization of 4D flow cardiovascular magnetic resonance with four-dimensional angiographic data: generation of a 4D phase-contrast magnetic resonance CardioAngiography (4D PC-MRCA)

被引:17
作者
Bustamante, Mariana [1 ,2 ]
Gupta, Vikas [1 ,2 ]
Carlhall, Carl-Johan [1 ,3 ]
Ebbers, Tino [1 ,2 ]
机构
[1] Linkoping Univ, Dept Med & Hlth Sci, Div Cardiovasc Med, Linkoping, Sweden
[2] Linkoping Univ, Ctr Med Image Sci & Visualizat CMIV, Linkoping, Sweden
[3] Linkoping Univ, Dept Med & Hlth Sci, Dept Clin Physiol, Linkoping, Sweden
基金
瑞典研究理事会; 欧洲研究理事会;
关键词
Computer-Assisted Image Analysis; 4D flow cardiovascular magnetic resonance (4D flow CMR); Phase-Contrast Magnetic Resonance Angiography (PC-MRA); WALL SHEAR-STRESS; BLOOD-FLOW; MRI; HEART;
D O I
10.1186/s12968-017-0360-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Magnetic Resonance Angiography (MRA) and Phase-Contrast MRA (PC-MRA) approaches used for assessment of cardiovascular morphology typically result in data containing information from the entire cardiac cycle combined into one 2D or 3D image. Information specific to each timeframe of the cardiac cycle is, however, lost in this process. This study proposes a novel technique, called Phase-Contrast Magnetic Resonance CardioAngiography (4D PC-MRCA), that utilizes the full potential of 4D Flow CMR when generating temporally resolved PC-MRA data to improve visualization of the heart and major vessels throughout the cardiac cycle. Using non-rigid registration between the timeframes of the 4D Flow CMR acquisition, the technique concentrates information from the entire cardiac cycle into an angiographic dataset at one specific timeframe, taking movement over the cardiac cycle into account. Registration between the timeframes is used once more to generate a time-resolved angiography. The method was evaluated in ten healthy volunteers. Visual comparison of the 4D PC-MRCAs versus PC-MRAs generated from 4D Flow CMR using the traditional approach was performed by two observers using Maximum Intensity Projections (MIPs). The 4D PC-MRCAs resulted in better visibility of the main anatomical regions of the cardiovascular system, especially where cardiac or vessel motion was present. The proposed method represents an improvement over previous PC-MRA generation techniques that rely on 4D Flow CMR, as it effectively utilizes all the information available in the acquisition. The 4D PC-MRCA can be used to visualize the motion of the heart and major vessels throughout the entire cardiac cycle.
引用
收藏
页数:10
相关论文
共 21 条
[1]  
Bock J., 2008, International Society for Magnetic Resonance in Medicine. Volume, V16, P3053
[2]   4D Phase Contrast MRI at 3 T: Effect of Standard and Blood-Pool Contrast Agents on SNR, PC-MRA, and Blood Flow Visualization [J].
Bock, Jelena ;
Frydrychowicz, Alex ;
Stalder, Aurelien F. ;
Bley, Thorsten A. ;
Burkhardt, Hans ;
Hennig, Juergen ;
Markl, Michael .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (02) :330-338
[3]   Atlas-based analysis of 4D flow CMR: Automated vessel segmentation and flow quantification [J].
Bustamante, Mariana ;
Petersson, Sven ;
Eriksson, Jonatan ;
Alehagen, Urban ;
Dyverfeldt, Petter ;
Carlhall, Carl-Johan ;
Ebbers, Tino .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
[4]  
Dumoulin C L, 1995, Magn Reson Imaging Clin N Am, V3, P399
[5]   4D flow cardiovascular magnetic resonance consensus statement [J].
Dyverfeldt, Petter ;
Bissell, Malenka ;
Barker, Alex J. ;
Bolger, Ann F. ;
Carlhall, Carl-Johan ;
Ebbers, Tino ;
Francios, Christopher J. ;
Frydrychowicz, Alex ;
Geiger, Julia ;
Giese, Daniel ;
Hope, Michael D. ;
Kilner, Philip J. ;
Kozerke, Sebastian ;
Myerson, Saul ;
Neubauer, Stefan ;
Wieben, Oliver ;
Markl, Michael .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
[6]  
Ebbers Tino., 2008, 16th meeting of the International Society for Magnetic Resonance in Medicine, page, P1367
[7]  
Forsberg D, 2012, NONRIGID DIFFEOMORPH, P304
[8]   Model-based registration for assessment of spinal deformities in idiopathic scoliosis [J].
Forsberg, Daniel ;
Lundstrom, Claes ;
Andersson, Mats ;
Knutsson, Hans .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (02) :311-326
[9]   Interdependencies of aortic arch secondary flow patterns, geometry, and age analysed by 4-dimensional phase contrast magnetic resonance imaging at 3 Tesla [J].
Frydrychowicz, Alex ;
Berger, Alexander ;
del Rio, Alejandro Munoz ;
Russe, Maximilian F. ;
Bock, Jelena ;
Harloff, Andreas ;
Markl, Michael .
EUROPEAN RADIOLOGY, 2012, 22 (05) :1122-1130
[10]   Applications of phase-contrast flow and velocity imaging in cardiovascular MRI [J].
Gatehouse, PD ;
Keegan, J ;
Crowe, LA ;
Masood, S ;
Mohiaddin, RH ;
Kreitner, KF ;
Firmin, DN .
EUROPEAN RADIOLOGY, 2005, 15 (10) :2172-2184