Extracting Instantaneous Respiratory Rate From Multiple Photoplethysmogram Respiratory-Induced Variations

被引:47
作者
Dehkordi, Parastoo [1 ]
Garde, Ainara [2 ]
Molavi, Behnam [3 ]
Ansermino, J. Mark [4 ]
Dumont, Guy A. [1 ]
机构
[1] Univ British Columbia, Fac Appl Sci, Elect & Comp Engn, Vancouver, BC, Canada
[2] Univ Twente, Fac Elect Engn Math & Comp Sci, Enschede, Netherlands
[3] Lionsgate Technol, Vancouver, BC, Canada
[4] Univ British Columbia, Anesthesiol Pharmacol & Therapeut, Vancouver, BC, Canada
关键词
instantaneous respiratory rate; pulse oximetry; photoplethysmogram; respiratory-induced variation; synchrosqueezing transform; HEART-RATE; SPECTRAL-ANALYSIS; ALGORITHMS; FREQUENCY; CHILDREN;
D O I
10.3389/fphys.2018.00948
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
In this study, we proposed a novel method for extracting the instantaneous respiratory rate (IRR) from the pulse oximeter photoplethysmogram (PPG). The method was performed in three main steps: (1) a time-frequency transform called synchrosqueezing transform (SST) was used to extract the respiratory-induced intensity, amplitude and frequency variation signals from PPG, (2) the second SST was applied to each extracted respiratory-induced variation signal to estimate the corresponding IRR, and (3) the proposed peak-conditioned fusion method then combined the IRR estimates to calculate the final IRR. We validated the implemented method with capnography and nasal/oral airflow as the reference RR using the limits of agreement (LOA) approach. Compared to simple fusion and single respiratory-induced variation estimations, peak-conditioned fusion shows better performance. It provided a bias of 0.28 bpm with the 95% LOAs ranging from -3.62 to 4.17, validated against capnography and a bias of 0.04 bpm with the 95% LOAs ranging from -5.74 to 5.82, validated against nasal/oral airflow. This algorithm would expand the functionality of a conventional pulse oximetry beyond the measurement of heart rate and oxygen saturation to measure the respiratory rate continuously and instantly.
引用
收藏
页数:10
相关论文
共 30 条
[1]  
Addison P.S., 2004, Int. J. Wavelets Multiresolution Inf. Process, V2, P43, DOI [10.1142/S0219691304000329, DOI 10.1142/S0219691304000329]
[2]   Developing an algorithm for pulse oximetry derived respiratory rate (RRoxi): a healthy volunteer study [J].
Addison, Paul S. ;
Watson, James N. ;
Mestek, Michael L. ;
Mecca, Roger S. .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2012, 26 (01) :45-51
[3]  
[Anonymous], 2007, J PHYS C SER, DOI DOI 10.1088/1742-6596/76/1/012045
[4]   An overview on assessing agreement with continuous measurements [J].
Barnhart, Huiman X. ;
Haber, Michael J. ;
Lin, Lawrence I. .
JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) :529-569
[5]   An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogram [J].
Charlton, Peter H. ;
Bonnici, Timothy ;
Tarassenko, Lionel ;
Clifton, David A. ;
Beale, Richard ;
Watkinson, Peter J. .
PHYSIOLOGICAL MEASUREMENT, 2016, 37 (04) :610-626
[6]   Estimation of Respiratory Rate From Photoplethysmogram Data Using Time-Frequency Spectral Estimation [J].
Chon, Ki H. ;
Dash, Shishir ;
Ju, Kihwan .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (08) :2054-2063
[7]   Measurement of respiratory rate from the photoplethysmogram in chest clinic patients [J].
Clifton D. ;
Douglas G.J. ;
Addison P.S. ;
Watson J.N. .
Journal of Clinical Monitoring and Computing, 2007, 21 (01) :55-61
[8]   Synchrosqueezed wavelet transforms: An empirical mode decomposition-like tool [J].
Daubechies, Ingrid ;
Lu, Jianfeng ;
Wu, Hau-Tieng .
APPLIED AND COMPUTATIONAL HARMONIC ANALYSIS, 2011, 30 (02) :243-261
[9]   Evaluation of cardiac modulation in children in response to apnea/hypopnea using the Phone Oximeter™ [J].
Dehkordi, Parastoo ;
Garde, Ainara ;
Karlen, Walter ;
Petersen, Christian L. ;
Wensley, David ;
Dumont, Guy A. ;
Ansermino, J. Mark .
PHYSIOLOGICAL MEASUREMENT, 2016, 37 (02) :187-202
[10]   RESPIRATORY RATE PREDICTS CARDIOPULMONARY ARREST FOR INTERNAL-MEDICINE INPATIENTS [J].
FIESELMANN, JF ;
HENDRYX, MS ;
HELMS, CM ;
WAKEFIELD, DS .
JOURNAL OF GENERAL INTERNAL MEDICINE, 1993, 8 (07) :354-360