A validated surrogate analyte LC-MS/MS assay for quantification of endogenous cortisol in human whole blood

被引:8
|
作者
Agrawal, Karan [1 ]
Voggu, Ramakrishna R. [1 ]
Pisek, Daniel [1 ]
Becht, Steven [2 ]
Chudnovskiy, Ross [1 ]
Dufour, Geraldine Mercier [3 ]
Arfvidsson, Cecilia [4 ]
Thomas, C. Eric [1 ]
机构
[1] Covance Labs Inc, 8211 SciCor Dr, Indianapolis, IN 46214 USA
[2] Covance Labs Inc, 3301 Kinsman Blvd, Madison, WI 53704 USA
[3] Covance Labs Inc, Otley Rd, Harrogate HG3 1PY, England
[4] AstraZeneca R&D, Clin Pharmacol & Safety Sci, Quantitat Pharmacol Clin Pharmacol, Gothenburg, Sweden
关键词
Cortisol; Whole blood; LC-MS/MS; Surrogate analyte; Supported liquid extraction; Bioanalysis; TANDEM MASS-SPECTROMETRY; QUANTITATION; AGREEMENT; PLASMA;
D O I
10.1016/j.jpba.2021.114028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cortisol is a steroid hormone that is frequently measured as a marker of stress, inflammation, and immune function. While commonly analyzed in saliva, hair, blood plasma and urine, a recent trend towards whole blood-based at-home collection devices has emerged, which necessitates development of more sensitive assays for cortisol in whole blood. To support the implementation of a patient-centric sampling approach in a drug development program, a fit-for-purpose surrogate analyte-based liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for cortisol in whole blood was developed using C-13(3)-cortisol as a surrogate analyte and cortisol-d6 as the internal standard. The surrogate analyte approach was chosen due to a lack of available cortisol-free whole blood and the absence of appropriately representative surrogate matrices. Samples were prepared using supported liquid extraction, and the LC-MS/MS analysis consisted of a 4.00 min analytical run. The method demonstrated linearity between 0.500 and 500 ng/mL of C-13(3)-cortisol, and accuracy, precision and robustness were all acceptable per current regulatory guidance for bioanalytical method validation of chromatographic assays for cortisol- and C-13(3)-cortisol-based quality control (QC) samples when quantified against a C-13(3)-cortisol calibration curve. The acceptable robustness of cortisol-based QCs when quantified against a C-13(3)-cortisol-based calibration curve also suggests parallelism between the analytes. These results indicate a viable surrogate analyte method, that is fit-for-purpose to analyze whole blood cortisol levels using a surrogate analyte LC-MS/MS approach. Evaluation of patient samples showed very promising comparability between whole blood and plasma cortisol concentrations, suggesting that whole blood could be used in place of or in addition to a plasma-based sampling protocol in clinical trials analyzing cortisol. Overall, this method presents a novel tool that is a first step in supporting the trend towards sample miniaturization and at-home sample collection, and may be readily used in clinical and diagnostic settings. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Identification and quantification of mepirapim and acetyl fentanyl in authentic human whole blood and urine samples by GC-MS/MS and LC-MS/MS
    Mochizuki, Akira
    Nakazawa, Hiroko
    Adachi, Noboru
    Takekawa, Kenichi
    Shojo, Hideki
    FORENSIC TOXICOLOGY, 2018, 36 (01) : 81 - 87
  • [32] A validated LC-MS/MS assay for simultaneous quantification of methotrexate and tofacitinib in rat plasma: application to a pharmacokinetic study
    Sharma, Kuldeep
    Giri, Kalpeshkumar
    Dhiman, Vinay
    Dixit, Abhishek
    Zainuddin, Mohd
    Mullangi, Ramesh
    BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (05) : 722 - 732
  • [33] Quantification of 33 antidepressants by LC-MS/MS—comparative validation in whole blood, plasma, and serum
    Deborah Montenarh
    Mathias P. Wernet
    Markus Hopf
    Hans H. Maurer
    Peter H. Schmidt
    Andreas H. Ewald
    Analytical and Bioanalytical Chemistry, 2014, 406 : 5939 - 5953
  • [34] Detection and quantification of 56 new psychoactive substances in whole blood and urine by LC-MS/MS
    Ambach, Lars
    Redondo, Ana Hernandez
    Koenig, Stefan
    Angerer, Verena
    Schuerch, Stefan
    Weinmann, Wolfgang
    BIOANALYSIS, 2015, 7 (09) : 1119 - 1136
  • [35] A multi-analyte LC-MS/MS method for screening and quantification of nitrosamines in sartans
    Chang, Shu-Han
    Chang, Ching-Chia
    Wang, Li-Jing
    Chen, Wei-Ching
    Fan, Shu-Yu
    Zang, Chi-Zong
    Hsu, Ya-Hui
    Lin, Mei-Chih
    Tseng, Su-Hsiang
    Wang, Der-Yuan
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2020, 28 (02) : 98 - 107
  • [36] Quantification of surrogate monoclonal antibodies in mouse serum using LC-MS/MS
    Mehl, John T.
    Landry, France
    Discenza, Lorell
    Sleczka, Bogdan
    Zhao, Qihong
    Shuster, David J.
    Madia, Priyanka
    DasGupta, Ruchira
    Rajendran, Surendran
    Sun, Huadong
    Ciccimaro, Eugene
    Olah, Timothy, V
    BIOANALYSIS, 2021, 13 (03) : 147 - 159
  • [37] Validated LC-MS/MS method for quantification of agomelatine in human plasma and its application in a pharmacokinetic study
    Patil, Satish R.
    Nerurkar, Ketan K.
    Kalamkar, Ashok M.
    Pukale, Vishwas
    Mangaonkar, Kiran V.
    Pingale, Satish G.
    JOURNAL OF MASS SPECTROMETRY, 2012, 47 (01): : 23 - 28
  • [38] An LC-MS/MS Validated Method for Quantification of Chlorzoxazone in Human Plasma and Its Application to a Bioequivalence Study
    He, Jiake
    Li, Ning
    Xu, Jiaqiu
    Zhu, Jing
    Yu, Yang
    Chen, Xijing
    Lu, Yang
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2019, 57 (08) : 751 - 757
  • [39] An immuno-enrichment free, validated quantification of tau protein in human CSF by LC-MS/MS
    Self, Wade
    Awwad, Khader
    Savaryn, John Paul
    Schulz, Michael
    PLOS ONE, 2022, 17 (06):
  • [40] Determination of Clopidogrel in Human Plasma by a Validated LC-MS/MS Method
    Svinarov, Dobrin A.
    Kasabova, Lilia V.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2012, 138 : A021 - A021