Electric cautery lowers the contamination threshold for infection of laparotomies

被引:46
作者
Soballe, PW
Nimbkar, NV
Hayward, I
Nielsen, TB
Drucker, WR
机构
[1] Uniformed Serv Univ Hlth Sci, Naval Med Res Inst, Bethesda, MD 20814 USA
[2] Uniformed Serv Univ Hlth Sci, Dept Surg, Bethesda, MD 20814 USA
关键词
D O I
10.1016/S0002-9610(98)00020-8
中图分类号
R61 [外科手术学];
学科分类号
摘要
BACKGROUND: Interplay between wound resistance factors and bacterial innoculum determines the risk of surgical infection. Since cautery causes more damage than the scalpel, our hypothesis is that lower numbers of bacteria are required to infect wounds made by electric cautery than to infect wounds made with a scalpel. METHODS: Abdominal fascia was incised in 375 rats by cold knife, cutting current, or coagulation current. Wounds were innoculated with increasing numbers of bacteria and histologically scored at 7 days for necrosis, inflammation, and abscess. RESULTS: Coagulation current causes more inflammation, necrosis, and abscesses than the scalpel at all bacterial levels. Electric cutting current is intermediate, causing more damage than the scalpel only after contamination reached 10(5). Above this threshold most wounds were infected in all groups. CONCLUSIONS: Electric coagulation current should be used only when the need for meticulous hemostasis outweighs the considerably increased risk of infection. Electric cutting current is less destructive but also less hemostatic; indications for its use are difficult to identify. (C) 1998 by Excerpta Medica, Inc.