High-Sensitivity Cardiac Troponin After Cardiac Stress Test: A Systematic Review and Meta-Analysis

被引:17
|
作者
Samaha, Eslam [1 ]
Avila, Audrey [1 ]
Helwani, Mohammad A. [1 ]
Ben Abdallah, Arbi [1 ]
Jaffe, Allan S. [3 ,4 ,5 ]
Scott, Mitchell G. [2 ]
Nagele, Peter [1 ,6 ]
机构
[1] Washington Univ, Sch Med, Dept Anesthesiol, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Dept Pathol & Immunol, St Louis, MO 63110 USA
[3] Mayo Clin, Dept Internal Med, Cardiovasc Div, Rochester, MN USA
[4] Mayo Clin, Dept Lab Med & Pathol, Core Clin Lab, Rochester, MN USA
[5] Med Sch, Rochester, MN USA
[6] Univ Chicago, Dept Anesthesia & Crit Care, 5841 South Maryland Ave,MC 4028,Room E-422, Chicago, IL 60637 USA
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2019年 / 8卷 / 06期
基金
美国国家卫生研究院;
关键词
myocardial ischemia; stress echocardiography; stress testing; troponin; MYOCARDIAL-ISCHEMIA; EXERCISE; ELEVATION; RELEASE; ASSAYS; RHYTHM;
D O I
10.1161/JAHA.118.008626
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The recent introduction of high-sensitivity cardiac troponin (hs-cTn) assays has allowed clinicians to measure hs-cTn before and after cardiac stress testing, but the hs-cTn release pattern and potential utility in identifying inducible myocardial ischemia are unclear. We thus conducted a systematic review and meta-analysis to improve our understanding of hs-cTn release associated with exercise and pharmacological stress testing. Methods and Results-Studies published between January 2008 and July 2016 that reported hs-cTn change values (high-sensitivity cardiac troponin T [hs-cTnT] or high-sensitivity cardiac troponin I [hs-cTnI]) in relation to cardiac stress testing were searched and reviewed by 2 independent screeners. Primary outcomes were pooled estimates of absolute and relative hs-cTn changes after cardiac stress test, stratified by the presence of inducible myocardial ischemia. This meta-analysis included 11 studies (n=2432 patients). After exercise stress testing, hs-cTnT increased by 0.5 ng/L or 11% (6 studies, n=406) and hs-cTnI by 2.4 ng/L or 41% (4 studies, n=365) in patients with inducible myocardial ischemia versus hs-cTnT by 1.1 ng/L or 18% (8 studies, n=629; P=0.29) and hs-cTnI by 1.8 ng/L or 72% (4 studies, n=831; P=0.61) in patients who did not develop inducible myocardial ischemia. After pharmacological stress test, hs-cTnT changed by -0.1 ng/L or -0.4% (6 studies, n=251) and hs-cTnI by 2.4 ng/L or 32% (2 studies, n=108) in patients with inducible myocardial ischemia versus hs-cTnT by 0.7 ng/L or 11% (5 studies, n=443, P=0.44) and hs-cTnI by 1.7 ng/L or 38% (2 studies, n=116; P=0.62) in patients who did not develop inducible myocardial ischemia. Conclusions-hs-cTn rising patterns after exercise and pharmacological stress testing appear inconsistent and comparably small, and do not appear to be correlated with inducible myocardial ischemia.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Cardiac troponin and heart failure in the era of high-sensitivity assays
    Sato, Yukihito
    Fujiwara, Hisayoshi
    Takatsu, Yoshiki
    JOURNAL OF CARDIOLOGY, 2012, 60 (3-4) : 160 - 167
  • [42] High-Sensitivity Cardiac Troponin Assays: Ready for Prime Time!
    Krychtiuk, Konstantin A.
    Newby, L. Kristin
    ANNUAL REVIEW OF MEDICINE, 2024, 75 : 459 - 474
  • [43] High-Sensitivity Cardiac Troponin Algorithms and the Value of Likelihood Ratios
    Fischer, Brett G.
    Evans, Arthur T.
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2023, 38 (09) : 2189 - 2193
  • [44] High-sensitivity Cardiac Troponin: From Theory to Clinical Practice
    Jaffe, Allan S.
    Ordonez-Llanos, Jordi
    REVISTA ESPANOLA DE CARDIOLOGIA, 2013, 66 (09): : 687 - 691
  • [45] High-Sensitivity Troponin T is a Prognostic Marker in Cardiac Sarcoidosis
    Kandolin, Riina
    Lehtonen, Jukka
    Kupari, Markku
    CIRCULATION, 2013, 128 (22)
  • [46] Association Between High-Sensitivity Cardiac Troponin I and Cardiac Events in Elderly Women
    Lewis, Joshua R.
    Lim, Wai H.
    Wong, Germaine
    Abbs, Samuel
    Zhu, Kun
    Lim, Ee M.
    Thompson, Peter L.
    Prince, Richard L.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (08):
  • [47] Comparing cardiac troponin levels using sevoflurane and isoflurane in patients undergoing cardiac surgery: a systematic review and meta-analysis
    Hosseinifard, Hossein
    Ghadimi, Nashmil
    Kaveh, Sara
    Shabaninejad, Hossein
    Lijassi, Alaadine
    Azarfarin, Rasoul
    JOURNAL OF CARDIOVASCULAR AND THORACIC RESEARCH, 2020, 12 (01) : 1 - 9
  • [48] Predictors of high-sensitivity cardiac troponin in stable patients undergoing coronary angiography
    Valina, Christian M.
    Amann, Michael
    Stratz, Christian
    Trenk, Dietmar
    Loffelhardt, Nikolaus
    Ferenc, Miroslav
    Neumann, Franz-Josef
    Hochholzer, Willibald
    EUROINTERVENTION, 2016, 12 (03) : 329 - 336
  • [49] High-sensitivity cardiac troponin: do think twice, it's not all right
    Ungerer, Jacobus P. J.
    Pretorius, Carel J.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (11) : 1669 - 1671
  • [50] Performance of High-Sensitivity Cardiac Troponin T in Etiologic Diagnosis After Out-of-Hospital Cardiac Arrest
    Geri, Guillaume
    Mongardon, Nicolas
    Dumas, Florence
    Chenevier-Gobeaux, Camille
    Varenne, Olivier
    Jouven, Xavier
    Vivien, Benoit
    Mira, Jean-Paul
    Empana, Jean-Philippe
    Spaulding, Christian
    Cariou, Alain
    CIRCULATION, 2013, 128 (22)