摘要
PURPOSE: To study the relationship between the optics quality of multifocal intraocular lenses (IOLs) and distance-corrected near, intermediate, and distance visual acuity to determine the degree to which optics quality must change to produce a significant difference in visual acuity. SETTING: Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. METHODS: Monocular distance-corrected visual acuity (decimal and logMAR) was measured at 4 m, 70 cm, and 30 cm under photopic and mesopic conditions in eyes with 1 of 3 multifocal IOL models. Visual acuity versus the "average modulation" of the IOL was assessed. RESULTS: The pupil diameter and patient age were similar between the 3 IOL groups (20 eyes each). A difference in average modulation (le, optics quality) up to 15% did not produce significant differences in mean visual acuity between 2 groups, however, there was a significant difference in mean visual acuity between 2 groups when the average modulation values differed by at least 25% The slope of the linear correlation between visual acuity and average modulation was 0.018 (r(2) = 0 91) under photopic conditions and 0.024 (r(2) = 0.089) under mesopic conditions. CONCLUSIONS: There was a strong linear correlation between IOL optics quality and visual acuity with distance correction under photopic conditions with a pupil of approximately 3.5 mm in a cohort in which the patient age was controlled. The correlation was similar under mesopic conditions. The eye's tolerance to modulation transfer function decay was approximately 15% of the average modulation value.
引用
收藏
页码:557 / 562
页数:6
相关论文
共 31 条
[1]   Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Baamonde, M. Begona ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03) :430-438
[2]   Visual function after implantation of an aspheric bifocal intraocular lens [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Amhaz, Hussein ;
Montes-Mico, Robert ;
Valcarcel, Beatriz ;
Ferrer-Blasco, Teresa .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (05) :885-892
[3]   Visual quality after diffractive intraocular lens implantation in eyes with previous myopic laser in situ keratomileusis [J].
Alfonso, Jose F. ;
Madrid-Costa, David ;
Poo-Lopez, Arancha ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11) :1848-1854
[4]   Outcomes of laser refractive surgery for myopia [J].
Ang, Eng K. ;
Couper, Terry ;
Dirani, Mohamed ;
Vajpayee, Rasik B. ;
Baird, Paul N. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (05) :921-933
[5]   Image quality with multifocal intraocular lenses and the effect of pupil size -: Comparison of refractive and hybrid refractive-diffractive designs [J].
Artigas, Jose M. ;
Menezo, Jose L. ;
Peris, Cristina ;
Felipe, Adelina ;
Diaz-Llopis, Manuel .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (12) :2111-2117
[6]   Modulation transfer function: Rigid versus foldable phakic intraocular lenses [J].
Artigas, Jose M. ;
Peris, Cristina ;
Felipe, Adelina ;
Menezo, Jose L. ;
Sanchez-Cortina, Isaias ;
Lopez-Gil, Norberto .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (04) :747-752
[7]   DESIGN OF ASPHERIC INTRAOCULAR LENSES [J].
ATCHISON, DA .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1991, 11 (02) :137-146
[8]   Astigmatism management in cataract surgery with the AcrySof toric intraocular lens [J].
Bauer, Noel J. C. ;
de Vries, Niels E. ;
Webers, Carroll A. B. ;
Hendrikse, Fred ;
Nuijts, Rudy M. M. A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09) :1483-1488
[10]   Accommodative intraocular lenses: considerations on use, function and design [J].
Doane, John F. ;
Jackson, Randolph T. .
CURRENT OPINION IN OPHTHALMOLOGY, 2007, 18 (04) :318-324