Correlation between optics quality of multifocal intraocular lenses and visual acuity Tolerance to modulation transfer function decay

被引:34
作者
Felipe, Adelina [1 ,2 ]
Pastor, Francisco [2 ]
Artigas, Jose M. [1 ,2 ]
Diez-Ajenjo, Amparo [2 ]
Gene, Andres
Menezo, Jose L. [2 ]
机构
[1] Univ Valencia, Fac Fis, Dept Opt, E-46100 Burjassot, Valencia, Spain
[2] Fundac Oftalmol Mediterraneo, Valencia, Spain
关键词
IN-SITU KERATOMILEUSIS; PUPIL SIZE; CONTRAST SENSITIVITY; IMAGE QUALITY; IMPLANTATION; MYOPIA; EYES; SATISFACTION; PERFORMANCE; ASTIGMATISM;
D O I
10.1016/j.jcrs.2009.10.046
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To study the relationship between the optics quality of multifocal intraocular lenses (IOLs) and distance-corrected near, intermediate, and distance visual acuity to determine the degree to which optics quality must change to produce a significant difference in visual acuity. SETTING: Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. METHODS: Monocular distance-corrected visual acuity (decimal and logMAR) was measured at 4 m, 70 cm, and 30 cm under photopic and mesopic conditions in eyes with 1 of 3 multifocal IOL models. Visual acuity versus the "average modulation" of the IOL was assessed. RESULTS: The pupil diameter and patient age were similar between the 3 IOL groups (20 eyes each). A difference in average modulation (le, optics quality) up to 15% did not produce significant differences in mean visual acuity between 2 groups, however, there was a significant difference in mean visual acuity between 2 groups when the average modulation values differed by at least 25% The slope of the linear correlation between visual acuity and average modulation was 0.018 (r(2) = 0 91) under photopic conditions and 0.024 (r(2) = 0.089) under mesopic conditions. CONCLUSIONS: There was a strong linear correlation between IOL optics quality and visual acuity with distance correction under photopic conditions with a pupil of approximately 3.5 mm in a cohort in which the patient age was controlled. The correlation was similar under mesopic conditions. The eye's tolerance to modulation transfer function decay was approximately 15% of the average modulation value.
引用
收藏
页码:557 / 562
页数:6
相关论文
共 31 条
  • [1] Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Baamonde, M. Begona
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03) : 430 - 438
  • [2] Visual function after implantation of an aspheric bifocal intraocular lens
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Amhaz, Hussein
    Montes-Mico, Robert
    Valcarcel, Beatriz
    Ferrer-Blasco, Teresa
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (05) : 885 - 892
  • [3] Visual quality after diffractive intraocular lens implantation in eyes with previous myopic laser in situ keratomileusis
    Alfonso, Jose F.
    Madrid-Costa, David
    Poo-Lopez, Arancha
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11) : 1848 - 1854
  • [4] Outcomes of laser refractive surgery for myopia
    Ang, Eng K.
    Couper, Terry
    Dirani, Mohamed
    Vajpayee, Rasik B.
    Baird, Paul N.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (05) : 921 - 933
  • [5] Image quality with multifocal intraocular lenses and the effect of pupil size -: Comparison of refractive and hybrid refractive-diffractive designs
    Artigas, Jose M.
    Menezo, Jose L.
    Peris, Cristina
    Felipe, Adelina
    Diaz-Llopis, Manuel
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (12) : 2111 - 2117
  • [6] Modulation transfer function: Rigid versus foldable phakic intraocular lenses
    Artigas, Jose M.
    Peris, Cristina
    Felipe, Adelina
    Menezo, Jose L.
    Sanchez-Cortina, Isaias
    Lopez-Gil, Norberto
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (04) : 747 - 752
  • [7] DESIGN OF ASPHERIC INTRAOCULAR LENSES
    ATCHISON, DA
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1991, 11 (02) : 137 - 146
  • [8] Astigmatism management in cataract surgery with the AcrySof toric intraocular lens
    Bauer, Noel J. C.
    de Vries, Niels E.
    Webers, Carroll A. B.
    Hendrikse, Fred
    Nuijts, Rudy M. M. A.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09) : 1483 - 1488
  • [10] Accommodative intraocular lenses: considerations on use, function and design
    Doane, John F.
    Jackson, Randolph T.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2007, 18 (04) : 318 - 324