Non-Contact Infrared-Depth Camera-Based Method for Respiratory Rhythm Measurement While Driving

被引:10
|
作者
Mateu-Mateus, Marc [1 ]
Guede-Fernandez, Federico [1 ]
Garcia-Gonzalez, Miguel A. [1 ]
Ramos-Castro, Juan [1 ]
Fernandez-Chimeno, Mireya [1 ]
机构
[1] Univ Politecn Cataluna, Dept Elect Engn, Barcelona 08034, Spain
关键词
Cameras; Feeds; Rhythm; Face; Thorax; Optical imaging; Real-time systems; Non-contact; respiration; IR; camera-based; point-cloud; computer vision; SIGNAL;
D O I
10.1109/ACCESS.2019.2947759
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This work proposes a new non-contact method based on Infrared and Depth cameras to measure respiratory rhythm in real-life situations. The proposed algorithm consists on using both video feeds to track the movements of the subject in real-time, compute the location of the face and calculate the most suitable ROI to extract the respiratory signal in adult population. 20 subjects were measured while driving in a car simulator with no constraints other than the simulator itself. The algorithm has been validated using a commercial thorax plethysmography system. An opportunistic approach has been used to obtain pieces from the tests for each subject, thus making a more realistic approach to the real-life situations where the signal is likely to contain errors. The breath-to-breath respiratory signal and the instantaneous frequency from both methods has been computed from each piece to characterise the error between the proposed method and the reference system. The results show a high correlation between the measured rhythm from the reference method and the proposed method, with relatively low error results and good sensitivity in cycle detection and low errors for the instantaneous frequency between methods. The error results have also been compared with the ones obtained in previous studies showing a good agreement between the obtained results and the ones presented in the previous studies. No relationship between the length of the pieces and the error has been found either for the respiratory cycle signal or the instantaneous frequency signal. The proposed algorithm can be used to measure respiratory rhythm in unconstrained conditions and with opportunistic measurements, thus making it suitable to perform in real-life situations while driving. Further studies taking into account vibrations or light changing conditions are needed to confirm that the proposed method performs with the same accuracy with these constraints.
引用
收藏
页码:152522 / 152532
页数:11
相关论文
共 18 条
  • [1] A non-contact camera-based method for respiratory rhythm extraction
    Mateu-Mateus, M.
    Guede-Fernandez, F.
    Rodriguez-Ibanez, N.
    Garcia-Gonzalez, M. A.
    Ramos-Castro, J.
    Fernandez-Chimeno, M.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 66
  • [2] Camera-Based Method for Respiratory Rhythm Extraction From a Lateral Perspective
    Mateu-Mateus, Marc
    Guede-Fernandez, Federico
    Angel Garcia-Gonzalez, Miguel
    Jose Ramos-Castro, Juan
    Fernandez-Chimeno, Mireya
    IEEE ACCESS, 2020, 8 : 154924 - 154939
  • [3] Non-contact Heart Rate Measurement based on Camera Image
    Kitajima, Toshihiro
    Choi, SangOn
    Murakami, Edwardo Arata Y.
    JOURNAL OF INFORMATION ASSURANCE AND SECURITY, 2015, 10 (03): : 120 - 129
  • [4] Research on non-contact respiratory rate measurement method based on video information
    Li S.
    Wang H.
    Liu Y.
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2021, 38 (06): : 1173 - 1180
  • [5] Non-contact sensing of neonatal pulse rate using camera-based imaging: a clinical feasibility study
    Paul, M.
    Karthik, S.
    Joseph, J.
    Sivaprakasam, M.
    Kumutha, J.
    Leonhardt, S.
    Antink, C. Hoog
    PHYSIOLOGICAL MEASUREMENT, 2020, 41 (02)
  • [6] Effect of Different Lighting Conditions on Camera-based Non-Contact Vital Sign Monitoring
    Raysad, Tushar
    Swarubini, P. J.
    Ganapathy, Nagarajan
    2024 IEEE APPLIED SENSING CONFERENCE, APSCON, 2024,
  • [7] Non-contact Measurement of Respiratory and Heart Rates Using a CMOS Camera-equipped Infrared Camera for Prompt Infection Screening at Airport Quarantine Stations
    Nakayama, Yosuke
    Sun, Guanghao
    Abe, Shigeto
    Matsui, Takemi
    2015 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND VIRTUAL ENVIRONMENTS FOR MEASUREMENT SYSTEMS AND APPLICATIONS (CIVEMSA), 2015, : 27 - 30
  • [8] Non-Contact Respiration Measurement Method Based on RGB Camera Using 1D Convolutional Neural Networks
    Hwang, Hyeon-Sang
    Lee, Eui-Chul
    SENSORS, 2021, 21 (10)
  • [9] Neonatal non-contact respiratory monitoring based on real-time infrared thermography
    Abbas K Abbas
    Konrad Heimann
    Katrin Jergus
    Thorsten Orlikowsky
    Steffen Leonhardt
    BioMedical Engineering OnLine, 10
  • [10] Vision-based automatic detection method for non-contact respiratory rate
    Liu J.
    Liu H.
    Jia X.
    Guo S.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2019, 40 (02): : 51 - 58