Highly Programmable Digital Controller for High-Density Epi-Retinal Prosthesis

被引:5
作者
Chen, Kuanfu [1 ]
Liu, Wentai [1 ]
机构
[1] Univ Calif Santa Cruz, Santa Cruz, CA 95064 USA
来源
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20 | 2009年
关键词
CHIP;
D O I
10.1109/IEMBS.2009.5334120
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents the analysis and circuit design of a digital controller supporting up to 1024-pixel epi-retinal prosthesis. High programmability of each stimulation pixel is desirable to support various physiological conditions. The goal of this design is to achieve high programmability with limited wireless transmission bandwidth. Two-tier architecture is adopted to reduce chip area. Several circuit blocks are developed in this design: on-chip address generator (OCAG) and configuration mode reduce the data bandwidth requirement by 54.7%; flexible data parser enables the optimization between data discard rate and maximum frame rate; delay timer makes any scanning pattern possible. Multi-clock domain and data gating design are used to reduce power. A prototype 256 pixels epi-retinal prosthesis controlled by the proposed digital controller is fabricated in a 0.18 mu m CMOS HV technology. This digital controller can be used in other implantable multi-channel stimulation systems.
引用
收藏
页码:1592 / 1595
页数:4
相关论文
共 7 条
[1]  
[Anonymous], 2009, Encyclopedia Britannica Online
[2]   Retinal prosthesis [J].
Liu, WT ;
Humayun, MS .
2004 IEEE INTERNATIONAL SOLID-STATE CIRCUITS CONFERENCE, DIGEST OF TECHNICAL PAPERS, 2004, 47 :218-219
[3]   A CUSTOM-DESIGNED RECEIVER-STIMULATOR CHIP FOR AN ADVANCED MULTIPLE-CHANNEL HEARING PROSTHESIS [J].
MCDERMOTT, H .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1991, 26 (08) :1161-1164
[4]   A 232-channel epiretinal stimulator ASIC [J].
Ortmanns, Maurits ;
Rocke, Andre ;
Gehrke, Marcus ;
Tiedtke, Hans-Jueergen .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2007, 42 (12) :2946-2959
[5]   Intraspinal stimulation for bladder voiding in bats before and after chronic spinal cord injury [J].
Pikov, Victor ;
Bullara, Leo ;
McCreery, Douglas B. .
JOURNAL OF NEURAL ENGINEERING, 2007, 4 (04) :356-368
[6]   A CMOS Chip With Active Pixel Array and Specific Test Features for Subretinal Implantation [J].
Rothermel, Albrecht ;
Liu, Liu ;
Aryan, Naser Pour ;
Fischer, Michael ;
Wuenschmann, Juergen ;
Kibbel, Steffen ;
Harscher, Alex .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2009, 44 (01) :290-300
[7]   Visual prosthesis [J].
Weiland, James D. ;
Humayun, Mark S. .
PROCEEDINGS OF THE IEEE, 2008, 96 (07) :1076-1084