DXA Performance in a Pediatric Population: Precision of Body Composition Measurements in Healthy Term-Born Infants Using Dual-Energy X-ray Absorptiometry

被引:18
作者
de Knegt, Victoria Elizabeth [1 ]
Carlsen, Emma Malchau [1 ]
Jensen, Jens-Erik Bech [2 ]
Rasmussen, Anne Melte Lade [2 ]
Pryds, Ole [1 ,3 ]
机构
[1] Hvidovre Univ Hosp, Dept Paediat, DK-2650 Hvidovre, Denmark
[2] Hvidovre Univ Hosp, Dept Endocrinol, DK-2650 Hvidovre, Denmark
[3] Univ Copenhagen, Fac Hlth Sci, Copenhagen, Denmark
关键词
Body composition; dual-energy X-ray absorptiometry; neonatal; term born; BONE-MINERAL CONTENT; PRETERM INFANTS; VALIDATION; ADIPOSITY;
D O I
10.1016/j.jocd.2014.08.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dual-energy X-ray absorptiometry (DXA) has been hailed as a golden standard for measuring body composition in adults but remains to be fully assessed for the infant population. A total of 64 newborn infants were allocated to 1 of 3 groups. All underwent 2 Hologic Discovery A DXA scans. Suboptimal scans were reconstructed, and an investigation into the success of adjustment was carried out. Depending on group, the factors of weight change and repositioning were investigated. Test-retest variation and coefficients of variation for DXA body composition estimates were calculated. Furthermore, the effects of flannel sheets and breast milk were investigated using a pediatric phantom. Reconstruction of suboptimal scans resulted in more accurate body weight estimates. Moderate weight change and repositioning had no significant effect on the variation between scans. No significant body composition changes occurred between scans. The test-retest variation varied between 6.3% and 11.8%. Flannel sheets and breast milk affected DXA results significantly. High precision of DXA measurements was obtained in our newborn population. Reconstructing scans is a viable way of correcting minor movement artifacts. Moderate weight changes and repositioning have no significant effect on DXA results, whereas flannel sheets and milk do.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 22 条
[1]   VALIDATION AND APPLICATION OF DUAL-ENERGY X-RAY ABSORPTIOMETRY TO MEASURE BONE MASS AND BODY-COMPOSITION IN SMALL INFANTS [J].
BRUNTON, JA ;
BAYLEY, HS ;
ATKINSON, SA .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 58 (06) :839-845
[2]   Adiposity Is Not Altered in Preterm Infants Fed With a Nutrient-Enriched Formula After Hospital Discharge [J].
Cooke, Richard J. ;
Griffin, Ian J. ;
McCormick, Kenny .
PEDIATRIC RESEARCH, 2010, 67 (06) :660-664
[3]   Altered body composition in preterm infants at hospital discharge [J].
Cooke, Richard J. ;
Griffin, Ian .
ACTA PAEDIATRICA, 2009, 98 (08) :1269-1273
[4]   Body Composition Assessment in the Infant [J].
Demerath, Ellen W. ;
Fields, David A. .
AMERICAN JOURNAL OF HUMAN BIOLOGY, 2014, 26 (03) :291-304
[5]  
Ellis KJ, 1996, J BONE MINER RES, V11, P843
[6]   Assessing Body Composition in Healthy Newborn Infants: Reliability of Dual-Energy X-Ray Absorptiometry [J].
Godang, Kristin ;
Qvigstad, Elisabeth ;
Voldner, Nanna ;
Isaksen, Gunhild A. ;
Froslie, Kathrine F. ;
Notthellen, Jacob ;
Henriksen, Tore ;
Bollerslev, Jens .
JOURNAL OF CLINICAL DENSITOMETRY, 2010, 13 (02) :151-160
[7]   Birth weight and subsequent risk of type 2 diabetes: A meta-analysis [J].
Harder, Thomas ;
Rodekamp, Elke ;
Schellong, Karen ;
Dudenhausen, Joachim W. ;
Plagemann, Andreas .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2007, 165 (08) :849-857
[8]  
Hologic Inc, MAN00214 HOL INC
[9]  
Jensen S. M., 2012, MATERN CHILD NUTR
[10]  
Khong P-L., 2013, Annals of the ICRP, V42, P9, DOI 10.1016/j.icrp.2012.10.001