4E analysis and multi-objective optimization of a CCHP cycle based on gas turbine and ejector refrigeration

被引:171
作者
Moghimi, Mahdi [1 ]
Emadi, Mohammadali [1 ]
Ahmadi, Pouria [2 ,3 ]
Moghadasi, Hesam [1 ]
机构
[1] IUST, Sch Mech Engn, Tehran 16844, Iran
[2] Univ Tehran, Coll Engn, Sch Mech Engn, Ctr Excellence Design & Optimizat Energy Syst, POB 11155-4563, Tehran, Iran
[3] UIUC, Inst Sustainabil Energy & Environm iSEE, Urbana, IL 61801 USA
关键词
Exergy; Thermo-economic; CCHP; HRSG; Ejector refrigeration system; Multi-objective optimization; ORGANIC RANKINE-CYCLE; POWER-SYSTEM; THERMOECONOMIC ANALYSIS; ENVIRONMENTAL-ANALYSES; PARAMETRIC ANALYSIS; ENERGY; EXERGY; DRIVEN; FEASIBILITY;
D O I
10.1016/j.applthermaleng.2018.05.075
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this research paper, the performance of a new configuration of a Combined Cooling, Heating and Power (CCHP) cycle including a Brayton cycle, a Rankine cycle, an ejector refrigeration cycle, and a domestic water heater is studied by utilization of 4E (energy, exergy, economic and environmental) analysis. Firstly, performance evaluation of the cycle is carried out using exergy and energy as a potential tool. In addition, an environmental assessment is applied to address the environmental impacts of the new multi-generation cycle and compare with the simple Brayton cycle. Results demonstrate that the CCHP cycle has greater exergy and energy efficiencies compared to a simple Brayton cycle. Moreover, the effects of several major design variables on the performance of the cycle are studied and the findings are presented. The major design parameters are gas turbine inlet temperature, compressor pressure ratio, heat recovery steam generator (HRSG) pressures, HRSG pinch point temperatures and regenerator effectiveness. In order to optimize the cycle and find the optimal selection of these design variable, two objective functions namely levelized total annual cost and exergy efficiency are defined and a multi-objective optimization is implemented. Based on the optimization outcomes, optimal points are found and the respective Pareto front is plotted. Comparing CCHP cycle to corresponding Brayton cycle, it is revealed that the CCHP cycle has higher exergy efficiency (7%) and energy efficiency (12%) rather than Brayton cycle.
引用
收藏
页码:516 / 530
页数:15
相关论文
共 38 条
  • [1] Performance assessment and optimization of a novel integrated multigeneration system for residential buildings
    Ahmadi, Pouria
    Dincer, Ibrahim
    Rosen, Marc A.
    [J]. ENERGY AND BUILDINGS, 2013, 67 : 568 - 578
  • [2] Thermodynamic modeling and multi-objective evolutionary-based optimization of a new multigeneration energy system
    Ahmadi, Pouria
    Dincer, Ibrahim
    Rosen, Marc A.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2013, 76 : 282 - 300
  • [3] Multi-objective exergy-based optimization of a polygeneration energy system using an evolutionary algorithm
    Ahmadi, Pouria
    Rosen, Marc A.
    Dincer, Ibrahim
    [J]. ENERGY, 2012, 46 (01) : 21 - 31
  • [4] Greenhouse gas emission and exergo-environmental analyses of a trigeneration energy system
    Ahmadi, Pouria
    Rosen, Marc A.
    Dincer, Ibrahim
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2011, 5 (06) : 1540 - 1549
  • [5] Exergy, exergoeconomic and environmental analyses and evolutionary algorithm based multi-objective optimization of combined cycle power plants
    Ahmadi, Pouria
    Dincer, Ibrahim
    Rosen, Marc A.
    [J]. ENERGY, 2011, 36 (10) : 5886 - 5898
  • [6] Exergoenvironmental analysis and optimization of a cogeneration plant system using Multimodal Genetic Algorithm (MGA)
    Ahmadi, Pouria
    Dincer, Ibrahim
    [J]. ENERGY, 2010, 35 (12) : 5161 - 5172
  • [7] Assessment of a novel heat-driven cycle to produce. shaft power and refrigeration
    Alelyani, Sami M.
    Sherbeck, Jonathan A.
    Fette, Nicholas W.
    Wang, Yuqian
    Phelan, Patrick E.
    [J]. APPLIED ENERGY, 2018, 215 : 751 - 764
  • [8] Thermodynamic analysis of a tri-generation system based on micro-gas turbine with a steam ejector refrigeration system
    Ameri, Mohammad
    Behbahaninia, Ali
    Tanha, Amir Abbas
    [J]. ENERGY, 2010, 35 (05) : 2203 - 2209
  • [9] [Anonymous], 2016, Chemical Engineering
  • [10] Thermo- economical consideration of Regenerative organic Rankine cycle coupling with the absorption chiller systems incorporated in the trigeneration system
    Anvari, Simin
    Taghavifar, Hadi
    Parvishi, Alireza
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2017, 148 : 317 - 329