Intra-cardiac 2D US to 3D CT image registration

被引:1
作者
Huang, Xishi [1 ,3 ]
Hill, Nicholas A. [2 ,3 ]
Ren, Jing [3 ,4 ]
Guiraudon, Gerard [3 ,5 ]
Peters, Terry M. [1 ,2 ,3 ]
机构
[1] Univ Western Ontario, Biomed Engn Grad Program, London, ON N6A 3K7, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[4] Univ Ontario, Inst Technol, Fac Engn & Appl Sci, Oshawa, ON, Canada
[5] CSTAR, London, ON, Canada
来源
MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2 | 2007年 / 6509卷
关键词
multimodal image registration; image-guided cardiac procedures; mutual information;
D O I
10.1117/12.711507
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intra-cardiac echocardiography (ICE) is commonly used to guide intra-cardiac procedures, such as the treatment of atrial fibrillation (AF). However, effective surgical navigation based on ICE images is not trivial, due to the low signal-tonoise ratio (SNR) and limited field of view of ultrasound (US) images. The interpretation of ICE can be significantly improved if correctly placed in the context of three-dimensional magnetic resonance (MR) or computed tomography (CT) images by simultaneously presenting the complementary anatomical information from the two modalities. The purpose of this research is to demonstrate the feasibility of multimodality image registration of 2D intra-cardiac US images with 3D computed tomography (CT) images. In our previous work, a two-step registration procedure has been proposed to register US images with NM images and was validated on a patient dataset. In this work, we extend the two-step method to intra-cardiac procedures and provide a detailed assessment of registration accuracy by determining the target registration errors (TRE) on a heart phantom, which had fiducial markers affixed to the surface to facilitate evaluation of registration accuracy. The resultant TRE on the heart phantom was 3.7 mm. This result is considered to be acceptable for guiding a probe in the heart during ablative therapy for atrial fibrillation. To our knowledge, there is no previous report describing multimodality registration of 2D intra-cardiac US to high-resolution 3D CT.
引用
收藏
页数:8
相关论文
共 16 条
[1]   Automated image registration of gated cardiac single-photon emission computed tomography and magnetic resonance imaging [J].
Aladl, UE ;
Hurwitz, GA ;
Dey, D ;
Levin, D ;
Drangova, M ;
Slomka, PJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (03) :283-290
[2]  
[Anonymous], P SPIE MED IMAG
[3]   Self-calibrating 3D-ultrasound-based bone registration for minimally invasive orthopedic surgery [J].
Barratt, DC ;
Penney, GP ;
Chan, CSK ;
Slomczykowski, M ;
Carter, TJ ;
Edwards, PJ ;
Hawkes, DJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (03) :312-323
[4]  
DUCHESNE S, 2001, MED IMAGE COMPUTING, P1189
[5]  
Gobbi DG, 1999, LECT NOTES COMPUT SC, V1679, P920
[6]  
GOBBI DG, 2002, LNCS, V2489, P156
[7]   En bloc exclusion of the pulmonary vein region in the pig using off pump, beating, intra-cardiac surgery: A pilot study of minimally invasive surgery for atrial fibrillation [J].
Guiraudon, GM ;
Jones, DL ;
Skanes, AC ;
Bainbridge, D ;
Guiraudon, CM ;
Jensen, SM ;
Yuan, XP ;
Drangova, M ;
Peters, TM .
ANNALS OF THORACIC SURGERY, 2005, 80 (04) :1417-1423
[8]   Medical image registration [J].
Hill, DLG ;
Batchelor, PG ;
Holden, M ;
Hawkes, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03) :R1-R45
[9]  
Huang XS, 2005, LECT NOTES COMPUT SC, V3750, P171, DOI 10.1007/11566489_22
[10]   Three-dimensional ultrasound-based navigation combined with preoperative CT during abdominal interventions:: A feasibility study [J].
Kaspersen, JH ;
Sjolie, E ;
Wesche, J ;
Åsland, J ;
Lundbom, J ;
Odegåord, A ;
Lindseth, F ;
Hernes, TAN .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 26 (04) :347-356