American Society for Therapeutic Radiology and Oncology and American College of Radiology Practice Guideline for the Performance of Stereotactic Body Radiation Therapy

被引:159
作者
Potters, L [1 ]
Steinberg, M
Rose, C
Timmerman, R
Ryu, S
Hevezi, JM
Welsh, J
Mehta, M
Larson, DA
Janjan, NA
机构
[1] S Nassau Communities Hosp, Dept Radiat Oncol, Oceanside, NY 11572 USA
[2] Santa Monica Canc Treatment Ctr, Dept Radiat Oncol, Santa Monica, CA USA
[3] Providence St Josephs Med Ctr, Dept Radiat Oncol, Burbank, CA USA
[4] Indiana Univ, Med Ctr, Dept Radiat Oncol, Indianapolis, IN USA
[5] Henry Ford Hlth Hosp, Dept Radiat Oncol, Detroit, MI USA
[6] Canc Therapy & Res Ctr S Texas, Dept Med Phys, San Antonio, TX USA
[7] Univ Wisconsin Hosp, Sch Med, Dept Human Oncol, Madison, WI USA
[8] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
[9] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2004年 / 60卷 / 04期
关键词
D O I
10.1016/j.ijrobp.2004.07.701
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The quality of a stereotactic body radiation therapy program is only as good as its weakest link. High spatial accuracies are expected, and time constraints are relatively short. Since SBRT uses either single fraction treatment or a hypofractionated regimen, there is little chance for adjustment once treatment has been initiated. This demands considerable time for planning and treatment verification by the radiation oncologist and medical physicist.
引用
收藏
页码:1026 / 1032
页数:7
相关论文
共 20 条
[1]  
Blomgren H, 1998, Journal of Radiosurgery, V1, P63
[2]   An analysis of the accuracy of the Cyberknife: A robotic nameless stereotactic radiosurgical system [J].
Chang, SD ;
Main, W ;
Martin, DP ;
Gibbs, IC ;
Heilbrun, MP .
NEUROSURGERY, 2003, 52 (01) :140-146
[3]   LINAC-based spinal stereotactic radiosurgery [J].
Hamilton, AJ ;
Lulu, BA ;
Fosmire, H ;
Gossett, L .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1996, 66 (1-3) :1-9
[4]   Stereotactic single-dose radiation therapy of liver tumors:: Results of a phase I/II trial [J].
Herfarth, KK ;
Debus, J ;
Lohr, F ;
Bahner, ML ;
Rhein, B ;
Fritz, P ;
Höss, A ;
Schlegel, W ;
Wannenmacher, MF .
JOURNAL OF CLINICAL ONCOLOGY, 2001, 19 (01) :164-170
[5]   Stereotactic single-dose radiotherapy of Stage I non-small-cell lung cancer (NSCLC) [J].
Hof, H ;
Herfarth, KK ;
Münter, M ;
Hoess, A ;
Motsch, J ;
Wannenmacher, M ;
Debus, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02) :335-341
[6]   How should we describe the radiobiologic effect of extracranial stereotactic radiosurgery: Equivalent uniform dose or tumor control probability? [J].
Kavanagh, BD ;
Timmerman, RD ;
Benedict, SH ;
Wu, Q ;
Schefter, TE ;
Stuhr, K ;
McCourt, S ;
Newman, F ;
Cardinale, RM ;
Gaspar, LE .
MEDICAL PHYSICS, 2003, 30 (03) :321-324
[7]   STEREOTAXIC RADIOTHERAPY OF MALIGNANCIES IN THE ABDOMEN - METHODOLOGICAL ASPECTS [J].
LAX, I ;
BLOMGREN, H ;
NASLUND, I ;
SVANSTROM, R .
ACTA ONCOLOGICA, 1994, 33 (06) :677-683
[8]   Noninvasive patient fixation for extracranial stereotactic radiotherapy [J].
Lohr, F ;
Debus, J ;
Frank, C ;
Herfarth, K ;
Pastyr, O ;
Rhein, B ;
Bahner, ML ;
Schlegel, W ;
Wannenmacher, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02) :521-527
[9]   An automatic six-degree-of-freedom image registration algorithm for image-guided frameless stereotaxic radiosurgery [J].
Murphy, MJ .
MEDICAL PHYSICS, 1997, 24 (06) :857-866
[10]   The accuracy of dose localization for an image-guided frameless radiosurgery system [J].
Murphy, MJ ;
Cox, RS .
MEDICAL PHYSICS, 1996, 23 (12) :2043-2049