Comparison of human skin opto-thermal response to near-infrared and visible laser irradiations: a theoretical investigation

被引:49
作者
Dai, TH [1 ]
Pikkula, BM
Wang, LV
Anvari, B
机构
[1] Rice Univ, Dept Bioengn, Houston, TX 77251 USA
[2] Texas A&M Univ, Dept Biomed Engn, College Stn, TX 77843 USA
关键词
D O I
10.1088/0031-9155/49/21/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Near-infrared wavelengths are absorbed less by epidermal melanin, and penetrate deeper into human skin dermis and blood than visible wavelengths. Therefore, laser irradiation using near-infrared wavelengths may improve the therapeutic outcome of cutaneous hyper-vascular malformations in moderately to heavily pigmented skin patients and those with large-sized blood vessels or blood vessels extending deeply into the skin. A mathematical model composed of a Monte Carlo algorithm to estimate the distribution of absorbed light, numerical solution of a bio-heat diffusion equation to calculate the transient temperature distribution, and a damage integral based on an empirical Arrhenius relationship to quantify the tissue damage was utilized to investigate the optothermal response of human skin to near-infrared and visible laser irradiations in conjunction with cryogen spray cooling. In addition, the thermal effects of a single continuous laser pulse and micropulse-composed laser pulse profiles were compared. Simulation results indicated that a 940 nm wavelength induces improved therapeutic outcome compared with a 585 and 595 nm wavelengths for the treatment of patients with large-sized blood vessels and moderately to heavily pigmented skin. On the other hand, a 585 nm wavelength shows the best efficacy in treating small-sized blood vessels, as characterized by the largest laser-induced blood vessel damage depth compared with 595 and 940 nm wavelengths. Dermal blood content has a considerable effect on the threshold incident dosage for epidermal damage, while the effect of blood vessel size is minimal. For the same macropulse duration and incident dosage, a micropulse-composed pulse profile results in higher peak temperature at the basal layer of skin epidermis than an ideal single continuous pulse profile.
引用
收藏
页码:4861 / 4877
页数:17
相关论文
共 32 条
[1]   RATE-PROCESS MODEL FOR ARTERIAL TISSUE THERMAL-DAMAGE - IMPLICATIONS ON VESSEL PHOTOCOAGULATION [J].
AGAH, R ;
PEARCE, JA ;
WELCH, AJ ;
MOTAMEDI, M .
LASERS IN SURGERY AND MEDICINE, 1994, 15 (02) :176-184
[2]   Influence of nozzle-to-skin distance in cryogen spray cooling for dermatologic laser surgery [J].
Aguilar, G ;
Majaron, B ;
Pope, K ;
Svaasand, LO ;
Lavernia, EJ ;
Nelson, JS .
LASERS IN SURGERY AND MEDICINE, 2001, 28 (02) :113-120
[3]   SELECTIVE PHOTOTHERMOLYSIS - PRECISE MICROSURGERY BY SELECTIVE ABSORPTION OF PULSED RADIATION [J].
ANDERSON, RR ;
PARRISH, JA .
SCIENCE, 1983, 220 (4596) :524-527
[4]   SELECTIVE COOLING OF BIOLOGICAL TISSUES - APPLICATION FOR THERMALLY MEDIATED THERAPEUTIC PROCEDURES [J].
ANVARI, B ;
MILNER, TE ;
TANENBAUM, BS ;
KIMEL, S ;
SVAASAND, LO ;
NELSON, JS .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (02) :241-252
[5]   TREATMENT OF A PORT-WINE STAIN IN A BLACK PATIENT WITH THE PULSED DYE-LASER [J].
ASHINOFF, R ;
GERONEMUS, RG .
JOURNAL OF DERMATOLOGIC SURGERY AND ONCOLOGY, 1992, 18 (02) :147-148
[6]   Chemical and structural changes in blood undergoing laser photocoagulation [J].
Black, JF ;
Barton, JK .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2004, 80 (01) :89-97
[7]  
Buscher BA, 2000, LASER SURG MED, V27, P171, DOI 10.1002/1096-9101(2000)27:2<171::AID-LSM9>3.0.CO
[8]  
2-V
[9]   A theoretical investigation of human skin thermal response to near-infrared laser irradiation [J].
Dai, TH ;
Pikkula, BM ;
Wang, LV ;
Anvari, B .
LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS XIV, 2004, 5312 :7-17
[10]  
DUCK FA, 1990, PHSICAL PROPERTIES T