Detection of different degree traumatic vertebral bone marrow oedema by virtual non-calcium technique of dual-source dual-energy CT

被引:14
作者
Wang, Y. [1 ]
Chen, Y. [1 ]
Zheng, H. [2 ]
Huang, X. [1 ]
Shan, C. [1 ]
Bao, Y. [1 ]
机构
[1] Hebei Gen Hosp, Med Imaging Dept, Shijiazhuang 050000, Hebei, Peoples R China
[2] Hebei Med Univ, Nucl Med Dept, Hosp 2, Shijiazhuang 050000, Hebei, Peoples R China
关键词
MULTIDETECTOR CT; BASIC PRINCIPLES; FRACTURES; LESIONS; OCCULT; PERFORMANCE; MANAGEMENT; DIAGNOSIS; AGE;
D O I
10.1016/j.crad.2019.09.143
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the diagnostic performance of dual-energy computed tomography (DECT) using the virtual non-calcium (VNCa) technique for the detection of different degrees of vertebral bone marrow oedema. MATERIALS AND METHODS: The present prospective study was approved by the institutional ethics committee. Informed consent was obtained from all patients. Twenty patients underwent both DECT and MRI. Vertebral bodies on VNCa images were graded visually by two blinded, independent radiologists using a three-point classification system (0=normal bone marrow, 2=distinct abnormal bone marrow attenuation). DECT values obtained from VNCa images were calculated by a third radiologist. Vertebral bodies on MRI images were graded by a forth radiologist using the same classification as DECT; magnetic resonance imaging (MRI) served as the reference standard. RESULTS: The agreement between VNCa and MRI images for the grading of bone marrow oedema was substantial (kappa=0.694). If MRI at grade 2 was regarded as positive for bone marrow oedema, VNCa images achieved an overall sensitivity of 85%, specificity of 97.5%, positive predictive value of 81%, negative predictive value of 98.1%. Receiver operating characteristic analysis based on CT values for the diagnosis of distinct bone marrow oedema revealed an area under the curve of 0.950. A cut-off value of -11.80 HU provided a sensitivity of 95% and specificity of 86.3% for the diagnosis of distinct bone marrow oedema at DECT. CONCLUSION: DECT images of VNCa showed excellent diagnostic performance for the detection of distinct vertebral bone marrow oedema. (C) 2019 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:156.e11 / 156.e19
页数:9
相关论文
共 30 条
[1]   Use of dual-energy CT and virtual non-calcium techniques to evaluate post-traumatic bone bruises in knees in the subacute setting [J].
Ai, Songtao ;
Qu, Mingliang ;
Glazebrook, Katrina N. ;
Liu, Yu ;
Rhee, Peter C. ;
Leng, Shuai ;
McCollough, Cynthia H. .
SKELETAL RADIOLOGY, 2014, 43 (09) :1289-1295
[2]   Dual-energy CT in vertebral compression fractures: performance of visual and quantitative analysis for bone marrow edema demonstration with comparison to MRI [J].
Bierry, Guillaume ;
Venkatasamy, Aina ;
Kremer, Stephane ;
Dosch, Jean-Claude ;
Dietemann, Jean-Louis .
SKELETAL RADIOLOGY, 2014, 43 (04) :485-492
[3]   Water/cortical bone decomposition: A new approach in dual energy CT imaging for bone marrow oedema detection. A feasibility study [J].
Biondi, M. ;
Vanzi, E. ;
De Otto, G. ;
Buonamici, F. Banci ;
Belmonte, G. M. ;
Mazzoni, L. N. ;
Guasti, A. ;
Carbone, S. F. ;
Mazzei, M. A. ;
La Penna, A. ;
Foder, E. ;
Guerreri, D. ;
Maiolino, A. ;
Volterrani, L. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12) :1712-1716
[4]   Follow-up of occult bone lesions detected at MR imaging: Systematic review [J].
Boks, SS ;
Vroegindeweij, D ;
Koes, BW ;
Hunink, MGM ;
Bierma-Zeinstra, SMA .
RADIOLOGY, 2006, 238 (03) :853-862
[5]   Good interrater reliability of a new grading system in detecting traumatic bone marrow lesions in the knee by dual energy CT virtual non-calcium images [J].
Cao, Jian-xin ;
Wang, Yi-min ;
Kong, Xiang-quan ;
Yang, Cheng ;
Wang, Peng .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (06) :1109-1115
[6]   Diagnostic Performance of Dual-Energy CT for the Detection of Traumatic Bone Marrow Lesions in the Ankle: Comparison with MR Imaging [J].
Guggenberger, Roman ;
Gnannt, Ralph ;
Hodler, Juerg ;
Krauss, Bernhard ;
Wanner, Guido A. ;
Csuka, Esther ;
Payne, Barbara ;
Frauenfelder, Thomas ;
Andreisek, Gustav ;
Alkadhi, Hatem .
RADIOLOGY, 2012, 264 (01) :164-173
[7]   Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1510-1517
[8]   Dual-Energy CT: General Principles [J].
Johnson, Thorsten R. C. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :S3-S8
[9]   The feasibility of dual-energy CT in differentiation of vertebral compression fractures [J].
Karaca, Leyla ;
Yuceler, Zeynep ;
Kantarci, Mecit ;
Cakir, Murteza ;
Sade, Recep ;
Calikoglu, Cagatay ;
Ogul, Hayri ;
Bayrakturan, U. Gulsum .
BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1057)
[10]   Dual-energy CT revisited with multidetector CT: review of principles and clinical applications [J].
Karcaaltincaba, Musturay ;
Aktas, Aykut .
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2011, 17 (03) :181-194