The nature of analogue-based free thyroxine estimates

被引:19
作者
Nelson, JC
Wang, R
Asher, DT
Wilcox, RB
机构
[1] Loma Linda Univ, Med Ctr, Dept Med, Loma Linda, CA 92354 USA
[2] Loma Linda Univ, Med Ctr, Dept Pathol, Loma Linda, CA USA
[3] Loma Linda Univ, Sch Med, Dept Biochem, Loma Linda, CA 92350 USA
[4] Quest Diagnost Nichols Inst, San Juan Capistrano, CA USA
关键词
D O I
10.1089/thy.2004.14.1030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Clinical laboratories often use analogue-based immunoassays to estimate serum free thyroxine (FT4) concentrations. These assays yield FT4 estimates that correlate closely with thyroxine (T-4) binding protein concentrations. This correlation implies that either T-4 binding proteins or protein bound T-4 contribute to analogue-based FT4 values. To study the contributions made by T-4 binding proteins to these FT4 estimates further, four analogue-based FT4 assays were applied to: (1) FT4 solutions without T-4 binding proteins, (2) to T-4 binding protein solutions without T-4, and (3) to total T-4 solutions containing T-4 binding protein, FT4, and protein-bound T-4. The FT4 estimates obtained with these solutions ranged from 0.2-8.6 ng/dL, when FT4 concentrations ranged from less than 0.2-12,000 ng/dL. In the FT4 solutions, gravimetrically determined FT4 concentrations were 500-12,000 ng/dL (0.5-12.0 mug/dL) without protein-bound T-4, and the FT4 estimates obtained were 0.3-6.9 ng/dL. In the total T4 solutions, dialyzable FT4 concentrations were less than 0.2-59 ng/dL*, retained T-4 concentrations were 499.8-11,441 ng/dL, and the analogue-based FT4 estimates obtained were 0.2-8.6 ng/dL. Similar FT4 estimates (0.2-8.6 ng/dL and 0.3-6.9 ng/dL) were obtained with similar concentrations of either protein-bound T-4 or FT4. Similar test results were associated with similar total T-4 concentrations, not similar FT4 concentrations. Protein-bound T-4 and T-4 binding protein contributed variably to test results. T-4 quantifications included large analytical losses that are unaccounted for. These assays passed tests of correlation with FT4 concentrations, but they failed tests of specificity for FT4 and accuracy in T-4 quantification.
引用
收藏
页码:1030 / 1036
页数:7
相关论文
共 22 条
[1]  
AMINO N, 1983, CLIN CHEM, V29, P321
[3]  
BOUNAUD JY, 1986, CLIN CHEM, V32, P565
[4]   Serum thyroxine binding capacity-dependent bias in an automated free thyroxine assay [J].
Christofides, ND ;
Wilkinson, E ;
Stoddart, M ;
Ray, DC ;
Beckett, GJ .
JOURNAL OF IMMUNOASSAY, 1999, 20 (04) :201-221
[5]  
CSAKO G, 1990, CLIN CHEM, V36, P645
[6]  
CSAKO G, 1989, CLIN CHEM, V35, P1655
[7]  
EKINS R, 1987, CLIN CHEM, V33, P2137
[8]  
EKINS R, 1978, FREE THYROID HORMONE, P78
[9]   Reference methods for the measurement of free thyroid hormones in blood evaluation of potential reference methods for free thyroxine [J].
Holm, SS ;
Hansen, SH ;
Faber, J ;
Staun-Olsen, P .
CLINICAL BIOCHEMISTRY, 2004, 37 (02) :85-93
[10]  
MEINHOLD H, 1985, NUC COMPACT, V16, P317