Hepatic lesion detection and characterization:: Value of nonenhanced MR imaging, superparamagnetic iron oxide-enhanced MR imaging, and spiral CT-ROC analysis

被引:137
作者
Reimer, P
Jähnke, N
Fiebich, M
Schima, W
Deckers, F
Marx, C
Holzknecht, N
Saini, S
机构
[1] Stadt Klinikum Karlsruhe, Dept Radiol, D-76133 Karlsruhe, Germany
[2] Univ Munster, Dept Clin Radiol, D-4400 Munster, Germany
[3] Univ Vienna, Dept Radiol, A-1010 Vienna, Austria
[4] Univ Ziekenhuis Antwerpen, Dept Radiol, Edegem, Belgium
[5] Ruhr Univ Bochum, Knappschafts Krankenhaus, Langendreer Klin, Dept Radiol, Bochum, Germany
[6] Univ Munich, Klinikum Grosshadern, Dept Diagnost Radiol, D-8000 Munich, Germany
[7] Massachusetts Gen Hosp, Dept Radiol, Div Abdominal & Intervent Radiol, Boston, MA 02114 USA
关键词
contrast media; iron; liver neoplasms; MR; magnetic resonance (MR);
D O I
10.1148/radiology.217.1.r00oc31152
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the accuracy for detection and characterization of focal hepatic lesions of nonenhanced, superparamagnetic iron oxide (SPIO)-enhanced, or a combination of nonenhanced and SPIO-enhanced MR imaging and contrast-enhanced spiral computed tomography (CT). MATERIALS AND METHODS: Spiral CT and T2-weighted SPIO-enhanced (ferucarbotran-enhanced) MR imaging were performed in 35 patients within 2 weeks before surgery for malignant hepatic lesions. Only malignant lesions with histopathologic proof were considered. A total of 875 images with and 800 images without focal lesions were presented to five readers, who were asked to assess the presence and characterization of lesions by using a five-point confidence scale. Receiver operating characteristic analysis was performed. RESULTS: Nonenhanced and SPIO-enhanced images together and SPIO-enhanced images alone yielded the best performance for lesion detection. No differences were found among all imaging techniques with regard to lesion characterization (benign vs malignant). The combined approach resulted in larger area under the ROC curve (A(z) = 0.9062) and accuracy (85.3%) (P < 0.02), as compared with SPIO-enhanced MR imaging (A(z) = 0.8667; accuracy, 73.1%). CONCLUSION: SPIO-enhanced T2-weighted MR imaging was more accurate than nonenhanced T1-weighted and T2-weighted MR imaging and contrast-enhanced spiral CT for the detection of focal hepatic lesions. The combined analysis of nonenhanced and SPIO-enhanced images was more accurate in the characterization of focal hepatic lesions than was review of SPIO-enhanced images alone.
引用
收藏
页码:152 / 158
页数:7
相关论文
共 35 条
[1]   LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING [J].
BELLIN, MF ;
ZAIM, S ;
AUBERTON, E ;
SARFATI, G ;
DURON, JJ ;
KHAYAT, D ;
GRELLET, J .
RADIOLOGY, 1994, 193 (03) :657-663
[2]   Hepatic lesion detection at MR imaging: A comparative study with four sequences [J].
Blakeborough, A ;
Ward, J ;
Wilson, D ;
Griffiths, M ;
Kajiya, Y ;
Guthrie, JA ;
Robinson, PJA .
RADIOLOGY, 1997, 203 (03) :759-765
[3]   FREE-RESPONSE METHODOLOGY - ALTERNATE ANALYSIS AND A NEW OBSERVER-PERFORMANCE EXPERIMENT [J].
CHAKRABORTY, DP ;
WINTER, LHL .
RADIOLOGY, 1990, 174 (03) :873-881
[4]   DEGENERACY AND DISCRETE RECEIVER OPERATING CHARACTERISTIC RATING DATA [J].
DORFMAN, DD ;
BERBAUM, KS .
ACADEMIC RADIOLOGY, 1995, 2 (10) :907-915
[5]   IRON-OXIDE ENHANCED MR-IMAGING OF THE LIVER AND SPLEEN - REVIEW OF THE 1ST-5 YEARS [J].
FERRUCCI, JT ;
STARK, DD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (05) :943-950
[6]   SUPERPARAMAGNETIC IRON OXIDE-ENHANCED MR IMAGING - PULSE SEQUENCE OPTIMIZATION FOR DETECTION OF LIVER-CANCER [J].
FRETZ, CJ ;
ELIZONDO, G ;
WEISSLEDER, R ;
HAHN, PF ;
STARK, DD ;
FERRUCCI, JT .
RADIOLOGY, 1989, 172 (02) :393-397
[7]   DETECTION OF HEPATIC METASTASES - COMPARISON OF CONTRAST-ENHANCED CT, UNENHANCED MR IMAGING, AND IRON-OXIDE ENHANCED MR IMAGING [J].
FRETZ, CJ ;
STARK, DD ;
METZ, CE ;
ELIZONDO, G ;
WEISSLEDER, R ;
SHEN, JH ;
WITTENBERG, J ;
SIMEONE, J ;
FERRUCCI, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (04) :763-770
[8]   Liver masses: Replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging [J].
Gaa, J ;
Hatabu, H ;
Jenkins, RL ;
Finn, JP ;
Edelman, RR .
RADIOLOGY, 1996, 200 (02) :459-464
[9]   DETECTION OF LIVER METASTASES - COMPARISON OF SUPERPARAMAGNETIC IRON OXIDE-ENHANCED AND UNENHANCED MR-IMAGING ART 1.5 T WITH DYNAMIC CT, INTRAOPERATIVE US, AND PERCUTANEOUS US [J].
HAGSPIEL, KD ;
NEIDL, KFW ;
EICHENBERGER, AC ;
WEDER, W ;
MARINCEK, B .
RADIOLOGY, 1995, 196 (02) :471-478
[10]   CLINICAL-APPLICATION OF SUPERPARAMAGNETIC IRON-OXIDE TO MR IMAGING OF TISSUE PERFUSION IN VASCULAR LIVER-TUMORS [J].
HAHN, PF ;
STARK, DD ;
WEISSLEDER, R ;
ELIZONDO, G ;
SAINI, S ;
FERRUCCI, JT .
RADIOLOGY, 1990, 174 (02) :361-366