Simultaneous Direct Analysis of Aflatoxins and Ochratoxin A in Cereals and Their Processed Products by Ultra-High Performance Liquid Chromatography with Fluorescence Detection

被引:24
作者
Dhanshetty, Manisha [1 ]
Banerjee, Kaushik [1 ]
机构
[1] ICAR Natl Res Ctr Grapes, Natl Referral Lab, Pune 412307, Maharashtra, India
关键词
IMMUNOAFFINITY COLUMN CLEANUP; MYCOTOXIN ANALYSIS; VALIDATION; ZEARALENONE; FOODS; HPLC;
D O I
10.5740/jaoacint.19-0048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Mycotoxins such as aflatoxins (AFs) and ochratoxin A (OTA) can pose severe health hazards because of their toxicity. Given a wide range of food matrices susceptible to fungal infections and possible cooccurrence of mycotoxins at different concentrations, validated multimycotoxin and multimatrix methods are strongly warranted. Objective: The aim of this research was to develop a simple and fast ultra-high performance LC (UHPLC) fluorescence detection (FLD)-based method to simultaneously determine AFs (B1, G1, B2, and G2) and OTA and, furthermore, to carry out single laboratory validation in a range of cereals and processed product matrices. Methods: The sample preparation involved homogenization and extraction with methanol water (80 + 20). For cleanup, an aliquot (3 mL) was diluted with phosphate-buffered saline, loaded on an immunoaffinity column (AFLAOCHRA PREP (R)), and eluted with methanol (1 mL). The cleaned extract was diluted with 0.2% acetic acid (at a 1:1 ratio) before injection into an ultra-high performance liquid chromatograph. To perform simultaneous analysis of AFs and OTA, the FLD program was developed by switching the excitation wavelength in a single chromatographic run. Results: The method provided LOQs of 0.25 and 1 ng/g for AFs and OTA, respectively, without involving any derivatization. In rice, the recoveries of AFs ranged from 84 to 106%, whereas OTA had a recovery above 72%, with the repeatability relative SDs <12% for both analytes. The method was successfully applied to a range of naturally contaminated market samples. Conclusions: The method is suitable for regulatory testing because of its significant time and cost effectiveness and sensitivity in compliance with the regulatory maximum levels. Highlights: The study achieves high-throughput analysis of AFs and OTA in raw and processed cereals using simultaneous extraction, cleanup, and UHPLC-FLD. Method sensitivity complies with the regulatory maximum levels. Single-laboratory validation results meet analytical QC requirements.
引用
收藏
页码:1666 / 1672
页数:7
相关论文
共 50 条
  • [21] Validation of analytical method for determination of ochratoxin A in cereals by C18 solid phase extraction and high-performance liquid chromatography with fluorescence detection
    Attallah, Emad R.
    Gomaa, Ahmed M.
    Amer, Mohamed E.
    Gad, Sohair A.
    JOURNAL OF FOOD AGRICULTURE & ENVIRONMENT, 2008, 6 (02): : 130 - 133
  • [22] Quantification of deoxynivalenol and -fumonisins in cereals and derived products by high-performance liquid chromatography
    Sahin, Hilal Zeynep
    Kabak, Bulent
    JOURNAL OF FOOD SAFETY AND FOOD QUALITY-ARCHIV FUR LEBENSMITTELHYGIENE, 2021, 72 (03): : 94 - 99
  • [23] Comparison of High Performance Liquid Chromatography with Fluorescence Detector and with Tandem Mass Spectrometry Methods for Detection and Quantification of Ochratoxin A in Green and Roasted Coffee Beans
    da Costa Cunha Bandeira, Raquel Duarte
    Uekane, Thais Matsue
    da Cunha, Carolina Passos
    Rodrigues, Janaina Marques
    Campino de la Cruz, Marcus Henrique
    de Oliveira Godoy, Ronoel Luiz
    Fioravante, Andreia de Lima
    BRAZILIAN ARCHIVES OF BIOLOGY AND TECHNOLOGY, 2013, 56 (06) : 911 - 920
  • [24] Simultaneous determination of fifteen illegal dyes in animal feeds and poultry products by ultra-high performance liquid chromatography tandem mass spectrometry
    Liu, Rongyuan
    Hei, Wenjing
    He, Pingli
    Li, Zhen
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (24): : 2416 - 2422
  • [25] Simultaneous measurement of phenylalanine and tyrosine by high performance liquid chromatography (HPLC) with fluorescence detection
    Neurauter, Gabriele
    Scholl-Buergi, Sabine
    Haara, Astrid
    Geisler, Simon
    Mayersbach, Peter
    Schennach, Harald
    Fuchs, Dietmar
    CLINICAL BIOCHEMISTRY, 2013, 46 (18) : 1848 - 1851
  • [26] Multimycotoxin analysis of crude extracts of nuts with ultra-high performance liquid chromatography/tandem mass spectrometry
    Skrbic, Biljana
    Zivancev, Jelena
    Godula, Michal
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2014, 34 (02) : 171 - 177
  • [27] Ultra-high performance liquid chromatography with fluorescence detection following salting-out assisted liquid-liquid extraction for the analysis of benzimidazole residues in farm fish samples
    Tejada-Casado, Carmen
    Lara, Francisco J.
    Garcia-Campana, Ana M.
    del Olmo-Lruela, Monsalud
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1543 : 58 - 66
  • [28] Ochratoxin A detection by spectrofluorimetry compared with high performance liquid chromatography in coffee
    Reche Ribeiro, Ricardo Marcelo
    Fujii, Simone
    Silva, Marcelo
    Nogari, Andreia Botega
    dos Santos Scholz, Maria Brigida
    Sataque Ono, Elisabete Yurie
    Kawamura, Osamu
    Hirooka, Elisa Yoko
    SEMINA-CIENCIAS AGRARIAS, 2008, 29 (02): : 331 - 337
  • [29] An improved method for simultaneous analysis of aminothiols in human plasma by high-performance liquid chromatography with fluorescence detection
    Cevasco, Giorgio
    Piatek, Anna Maria
    Scapolla, Carlo
    Thea, Sergio
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (14) : 2158 - 2162
  • [30] Multi-mycotoxin determination in cereals and derived products marketed in Tunisia using ultra-high performance liquid chromatography coupled to triple quadrupole mass spectrometry
    Oueslati, Souheib
    Romero-Gonzalez, Roberto
    Lasram, Salma
    Garrido Frenich, Antonia
    Martinez Vidal, Jose Luis
    FOOD AND CHEMICAL TOXICOLOGY, 2012, 50 (07) : 2376 - 2381