Reproducibility and accuracy of measuring unerupted teeth using limited cone beam X-ray CT

被引:23
作者
Sakabe, J.
Kuroki, Y.
Fujimaki, S.
Nakajima, I.
Honda, K.
机构
[1] Nihon Univ, Sch Dent, Dept Pediat Dent, Chiyoda Ku, Tokyo 1010062, Japan
[2] Nihon Univ, Sch Dent, Dept Radiol, Tokyo 1010062, Japan
关键词
cone beam CT; tooth size prediction; reproducibility; accuracy;
D O I
10.1259/dmfr/65418489
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The purpose of this investigation was to determine the reproducibility among observers and accuracy of the measurement of the tooth crown width of unerupted teeth using limited area cone beam X-ray CT. Methods: 3DX multi-image micro-CT (3DX, Morita Co., Kyoto, Japan) images of impacted supernumerary teeth in the median maxillary region taken prior to extraction were used for the samples. The width of the tooth on the 3DX image was measured five times by five individual observers. Significant differences in values among the observers in the measurement were determined by one-way analysis of variance for examining reproducibility. The measurement results of the ten samples on 3DX images were compared with the laboratory measurements using a three-dimensional co-ordinate measuring apparatus, using the Wilcoxon signed-rank sum test. Results: There was no significant difference among the observers in the measurement (P > 0.05). The measurement results shown on 3DX images were significantly larger than those of the laboratory measurements (P < 0.05). The mean difference was +0.088 mm. Conclusions: 3DX has high reproducibility for measuring the tooth crown width of unerupted teeth. While 3DX measurement values were larger than the laboratory measurements, the difference is clinically insignificant.
引用
收藏
页码:2 / 6
页数:5
相关论文
共 15 条
[1]   Development of a compact computed tomographic apparatus for dental use [J].
Arai, Y ;
Tammisalo, E ;
Iwai, K ;
Hashimoto, K ;
Shinoda, K .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) :245-248
[2]  
BUGG JL, 1985, TXB PEDIAT DENT, P594
[3]  
DALE JG, 2000, ORTHODONTICS CURRENT, P375
[4]   A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine [J].
Hashimoto, K ;
Arai, Y ;
Iwai, K ;
Araki, M ;
Kawashima, S ;
Terakado, M .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2003, 95 (03) :371-377
[5]  
Hixon EH., 1958, Angle Orthod, V28, P236
[6]   Evaluation of the usefulness of the limited cone-beam CT (3DX) in the assessment of the thickness of the roof of the glenoid fossa of the temporomandibular joint [J].
Honda, K ;
Arai, Y ;
Kashima, M ;
Takano, Y ;
Sawada, K ;
Ejima, K ;
Iwai, K .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (06) :391-395
[7]   Ortho cubic super-high resolution computed tomography: A new radiographic technique with application to the temporomandibular joint [J].
Honda, K ;
Larheim, TA ;
Johannessen, S ;
Arai, Y ;
Shinoda, K ;
Westesson, PL .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2001, 91 (02) :239-243
[8]  
HUCKABA GW, 1964, DENT CLIN N AM, P431
[9]  
Mah James, 2003, J Calif Dent Assoc, V31, P835
[10]  
Moyer's R. E., 1988, HDB ORTHODONTICS, P221