Excellent Glycemic Control Maintained by Open-Source Hybrid Closed-Loop AndroidAPS During and After Sustained Physical Activity

被引:59
|
作者
Petruzelkova, Lenka [1 ,2 ]
Soupal, Jan [3 ]
Plasova, Veronika [1 ,2 ]
Jiranova, Pavlina [1 ,2 ]
Neuman, Vit [1 ,2 ]
Plachy, Lukas [1 ,2 ]
Pruhova, Stepanka [1 ,2 ]
Sumnik, Zdenek [1 ,2 ]
Obermannova, Barbora [1 ,2 ]
机构
[1] Charles Univ Prague, Univ Hosp Motol, Dept Pediat, V Uvalu 84, Prague 15006 5, Czech Republic
[2] Charles Univ Prague, Fac Med 2, V Uvalu 84, Prague 15006 5, Czech Republic
[3] Charles Univ Prague, Fac Med 1, Dept Internal Med 3, Prague, Czech Republic
关键词
Open-source hybrid closed loop; AndroidAPS; Do-it-yourself systems; ARTIFICIAL PANCREAS; AFTERNOON EXERCISE; INSULIN SUSPENSION; PUMP THERAPY; TYPE-1; ADOLESCENTS; HYPOGLYCEMIA; CHILDREN; TECHNOLOGY; PREVENTION;
D O I
10.1089/dia.2018.0214
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Officially licensed hybrid closed-loop systems are not currently available worldwide; therefore, open-source systems have become increasingly popular. Our aim was to assess the safety, feasibility, and efficacy of an open-source hybrid closed-loop system (AndroidAPS) versus SmartGuard((R)) technology for day-and-night glucose control in children under extreme sports conditions. Research Design and Methods: Twenty-two children (16 girls, 6-15 years of age, median HbA1c 569mmol/mol) were enrolled in this pivotal winter sports camp study. The participants were divided into two groups using either the AndroidAPS or SmartGuard technology. Physical exertion was represented by all-day alpine skiing. The primary endpoints were mean glucose level, time below the threshold of 3.9mmol/L, and time within the target range of 3.9 to 10mmol/L. Results: The children using the AndroidAPS had significantly lower mean glycemia levels (7.2 +/- 2.7 vs. 7.7 +/- 2.8mmol/L; 129.6 +/- 49 vs. 138.6 +/- 50mg/dL, P<0.042) than the children using the SmartGuard. The proportion of time below the target (median 5.0%+/- 2.5% vs. 3.0%+/- 2.3%, P=0.6) and in the target zone (63%+/- 9.5% vs. 63%+/- 18%, P=0.5) did not significantly differ. The AndroidAPS group experienced more frequent malfunctions of the cannula set (median 0.8 +/- 0.4 vs. 0.2 +/- 0.4, P=0.02), which could have affected the results. No significant difference was found in the amount of carbohydrates consumed for the prevention and treatment of hypoglycemia [median 40 +/- 23 vs. 25 +/- 29g/(patient 3 days)]. No episodes of severe hypoglycemia or other serious adverse events were noted. Conclusions: This pilot study showed that the AndroidAPS system was a safe and feasible alternative to the SmartGuard Technology.
引用
收藏
页码:744 / 750
页数:7
相关论文
共 50 条
  • [31] Closed-loop and open-loop control of posture and movement during human trunk bending
    A. V. Alexandrov
    A. A. Frolov
    Biological Cybernetics, 2011, 104 : 425 - 438
  • [32] Bolusing frequency and amount impacts glucose control during hybrid closed-loop
    Bally, L.
    Thabit, H.
    Ruan, Y.
    Mader, J. K.
    Kojzar, H.
    Dellweg, S.
    Benesch, C.
    Hartnell, S.
    Leelarathna, L.
    Wilinska, M. E.
    Evans, M. L.
    Arnolds, S.
    Pieber, T. R.
    Hovorka, R.
    DIABETIC MEDICINE, 2018, 35 (03) : 347 - 351
  • [33] The benefit of subcutaneous glucagon during closed-loop glycemic control in rats with type 1 diabetes
    Ward, W. Kenneth
    Engle, Julia
    Duman, Heather M.
    Bergstrom, Colin P.
    Kim, Sonia F.
    Federiuk, Isaac E.
    IEEE SENSORS JOURNAL, 2008, 8 (1-2) : 89 - 96
  • [34] Glycemic Control and Change in Insulin Dose with Real-Life Use of Hybrid Closed-Loop System
    Giordano, Dominique A.
    Snell-Bergeon, Janet K.
    Joseph, Hal
    Garg, Satish K.
    Akturk, Halis K.
    DIABETES, 2019, 68
  • [35] NexRAN: Closed-loop RAN slicing in POWDER - A top-to-bottom open-source open-RAN use case
    Johnson, David
    Maas, Dustin
    Van Der Merwe, Jacobus
    PROCEEDINGS OF THE FIFTEENTH ACM WORKSHOP ON WIRELESS NETWORK TESTBEDS, EXPERIMENTAL EVALUATION & CHARACTERIZATION, WINTECH 2021, 2021, : 17 - 23
  • [36] Conceptualization and validation of an open-source closed-loop deep brain stimulation system in rat (vol 5, 2015)
    Wu, Hemmings
    Ghekiere, Hartwin
    Beeckmans, Dorien
    Tambuyzer, Tim
    van Kuyck, Kris
    Aerts, Jean-Marie
    Nuttin, Bart
    SCIENTIFIC REPORTS, 2018, 8
  • [37] Dareplane: a modular open-source software platform for BCI research with application in closed-loop deep brain stimulation
    Dold, Matthias
    Pereira, Joana
    Sajonz, Bastian
    Coenen, Volker A.
    Thielen, Jordy
    Janssen, Marcus L. F.
    Tangermann, Michael
    JOURNAL OF NEURAL ENGINEERING, 2025, 22 (02)
  • [38] Fly-by-Pi: Open source closed-loop control for geotechnical centrifuge testing applications
    Broekman, Andre
    Jacobsz, Schalk Willem
    Louw, Hendrik
    Kearsley, Elsabe
    Gaspar, Tiago
    Burke, Talia Simone Da Silva
    HARDWAREX, 2020, 8 (08):
  • [39] A Hybrid Open/Closed-Loop μ Control Method for Achieving Consistent Transient Performance in Turbofan Engines
    Long, Yifu
    Wang, Xi
    Liu, Jiashuai
    ACTUATORS, 2024, 13 (12)
  • [40] A Cross-Regulated Closed-Loop Control for Hybrid L-Z Source Inverter
    Chauhan, Avneet Kumar
    Mulpuru, Sai Teja
    Jain, Mayank
    Singh, Santosh Kumar
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (02) : 1983 - 1997