Excellent Glycemic Control Maintained by Open-Source Hybrid Closed-Loop AndroidAPS During and After Sustained Physical Activity

被引:59
|
作者
Petruzelkova, Lenka [1 ,2 ]
Soupal, Jan [3 ]
Plasova, Veronika [1 ,2 ]
Jiranova, Pavlina [1 ,2 ]
Neuman, Vit [1 ,2 ]
Plachy, Lukas [1 ,2 ]
Pruhova, Stepanka [1 ,2 ]
Sumnik, Zdenek [1 ,2 ]
Obermannova, Barbora [1 ,2 ]
机构
[1] Charles Univ Prague, Univ Hosp Motol, Dept Pediat, V Uvalu 84, Prague 15006 5, Czech Republic
[2] Charles Univ Prague, Fac Med 2, V Uvalu 84, Prague 15006 5, Czech Republic
[3] Charles Univ Prague, Fac Med 1, Dept Internal Med 3, Prague, Czech Republic
关键词
Open-source hybrid closed loop; AndroidAPS; Do-it-yourself systems; ARTIFICIAL PANCREAS; AFTERNOON EXERCISE; INSULIN SUSPENSION; PUMP THERAPY; TYPE-1; ADOLESCENTS; HYPOGLYCEMIA; CHILDREN; TECHNOLOGY; PREVENTION;
D O I
10.1089/dia.2018.0214
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Officially licensed hybrid closed-loop systems are not currently available worldwide; therefore, open-source systems have become increasingly popular. Our aim was to assess the safety, feasibility, and efficacy of an open-source hybrid closed-loop system (AndroidAPS) versus SmartGuard((R)) technology for day-and-night glucose control in children under extreme sports conditions. Research Design and Methods: Twenty-two children (16 girls, 6-15 years of age, median HbA1c 569mmol/mol) were enrolled in this pivotal winter sports camp study. The participants were divided into two groups using either the AndroidAPS or SmartGuard technology. Physical exertion was represented by all-day alpine skiing. The primary endpoints were mean glucose level, time below the threshold of 3.9mmol/L, and time within the target range of 3.9 to 10mmol/L. Results: The children using the AndroidAPS had significantly lower mean glycemia levels (7.2 +/- 2.7 vs. 7.7 +/- 2.8mmol/L; 129.6 +/- 49 vs. 138.6 +/- 50mg/dL, P<0.042) than the children using the SmartGuard. The proportion of time below the target (median 5.0%+/- 2.5% vs. 3.0%+/- 2.3%, P=0.6) and in the target zone (63%+/- 9.5% vs. 63%+/- 18%, P=0.5) did not significantly differ. The AndroidAPS group experienced more frequent malfunctions of the cannula set (median 0.8 +/- 0.4 vs. 0.2 +/- 0.4, P=0.02), which could have affected the results. No significant difference was found in the amount of carbohydrates consumed for the prevention and treatment of hypoglycemia [median 40 +/- 23 vs. 25 +/- 29g/(patient 3 days)]. No episodes of severe hypoglycemia or other serious adverse events were noted. Conclusions: This pilot study showed that the AndroidAPS system was a safe and feasible alternative to the SmartGuard Technology.
引用
收藏
页码:744 / 750
页数:7
相关论文
共 50 条
  • [21] Erratum: Conceptualization and validation of an open-source closed-loop deep brain stimulation system in rat
    Hemmings Wu
    Hartwin Ghekiere
    Dorien Beeckmans
    Tim Tambuyzer
    Kris van Kuyck
    Jean-Marie Aerts
    Bart Nuttin
    Scientific Reports, 8
  • [22] GoFish: A low-cost, open-source platform for closed-loop behavioural experiments on fish
    Ajuwon, Victor
    Cruz, Bruno F.
    Carrico, Paulo
    Kacelnik, Alex
    Monteiro, Tiago
    BEHAVIOR RESEARCH METHODS, 2024, 56 (01) : 318 - 329
  • [23] EyeLoop: An Open-Source System for High-Speed, Closed-Loop Eye-Tracking
    Arvin, Simon
    Rasmussen, Rune Nguyen
    Yonehara, Keisuke
    FRONTIERS IN CELLULAR NEUROSCIENCE, 2021, 15
  • [24] GoFish: A low-cost, open-source platform for closed-loop behavioural experiments on fish
    Victor Ajuwon
    Bruno F. Cruz
    Paulo Carriço
    Alex Kacelnik
    Tiago Monteiro
    Behavior Research Methods, 2024, 56 : 318 - 329
  • [25] Towards Closed-loop Automation in 5G Open RAN: Coupling an Open-Source Simulator with xApps
    Karamplias, Theofanis
    Spantideas, Sotirios T.
    Giannopoulos, Anastasios E.
    Gkonis, Panagiotis
    Kapsalis, Nikolaos
    Trakadas, Panagiotis
    2022 JOINT EUROPEAN CONFERENCE ON NETWORKS AND COMMUNICATIONS & 6G SUMMIT (EUCNC/6G SUMMIT), 2022, : 232 - 237
  • [26] Postoperative Closed-loop Glycemic Control Using an Artificial Pancreas in Patients After Esophagectomy
    Kitagawa, Hiroyuki
    Yatabe, Tomoaki
    Namikawa, Tsutomu
    Munekage, Masaya
    Hanazaki, Kazuhiro
    ANTICANCER RESEARCH, 2016, 36 (08) : 4063 - 4067
  • [27] SimBSI: An open-source Simulink library for developing closed-loop brain signal interfaces in animals and humans
    Ojeda, Alejandro
    Buscher, Nathalie
    Balasubramani, Pragathi
    Maric, Vojislav
    Ramanathan, Dhakshin
    Mishra, Jyoti
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (03)
  • [28] Open-Source Real-Time Closed-Loop Electrical Threshold Tracking for Translational Pain Research
    Nickerson, Aidan P.
    Newton, Graeme W. T.
    O'Sullivan, James H.
    Martinez-Perez, Manuel
    Sales, Anna C.
    Williams, Gethin
    Pickering, Anthony E.
    Dunham, James P.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (194):
  • [29] RPM: An open-source Rotation Platform for open- and closed-loop vestibular stimulation in head-fixed Mice
    Cano-Ferrer, Xavier
    -Minh, Alexandra Tran -Van
    Rancz, Ede
    JOURNAL OF NEUROSCIENCE METHODS, 2024, 401
  • [30] Closed-loop and open-loop control of posture and movement during human trunk bending
    Alexandrov, A. V.
    Frolov, A. A.
    BIOLOGICAL CYBERNETICS, 2011, 104 (06) : 425 - 438