A new coated ion-selective electrode for the determination of trace vanadyl ions (VO2+) by flow injection potentiometry (FIP) with a home-made flow cell has been developed. The PVC-based membrane was coated on a graphite electrode with an effective area of 4.90 mm(2). The optimum membrane contains 5 wt.% 1,8-diaminonaphtalene as ionophore, 35 wt.% plasticizer 2-nitrophenyl octyl ether, 55 wt.% PVC and 5 wt.% additive potassium tetrakis (p-chlorophenyl) borate. The electrode in flow injection potentiometry resulted in well defined peaks for vanadyl ions with a very high sampling rate (180 injections/h). Linear calibration was obtained from 1.14 x 10(-7) to 1.14 x 10(-1) M vanadyl ions, with a slope of 28.3 +/- 0.3 mV per decade change in vanadyl concentration, and very low detection limit of 1.14 x 10(-7) M and the electrode can be used for at least I months without any considerable change in potential response. Selectivity coefficients for several ions were obtained by the matched potential method with respect VO2+ ions. The flow cell is simple to construct and free from memory effect problems over long periods of use. The sensor was used for the recovery of trace VO2+ ions from tap water and the determination of VO2+ in synthetic sample. (C) 2003 Elsevier Science B.V All rights reserved.
引用
收藏
页码:213 / 219
页数:7
相关论文
共 33 条
[1]  
Alexander PW, 1998, ELECTROANAL, V10, P707, DOI 10.1002/(SICI)1521-4109(199808)10:10<707::AID-ELAN707>3.3.CO
[2]  
2-M
[3]   Cesium-selective poly(vinylchloride) membrane electrode based on a new calix[4]arene derivative in the 1,3-alternate conformation [J].
Arvand-Barmchi, M ;
Mousavi, MF ;
Zanjanchi, MA ;
Taghvaei, S .
ANALYTICAL LETTERS, 2002, 35 (05) :767-783
[4]  
Berman E, 1980, TOXIC METALS THEIR A, P221
[5]  
CAMMANN K, 1988, FRESEN J ANAL CHEM, V329, P6910
[6]  
Clark R.J. H., 1968, The Chemistry of Titanium and Vanadium
[7]   SIMULTANEOUS DETERMINATIONS IN FLOW-INJECTION ANALYSIS - A REVIEW [J].
DECASTRO, MDL ;
CASES, MV .
ANALYST, 1984, 109 (04) :413-419
[8]  
GANZEKPO VPY, 1984, ANAL CHIM ACTA, V164, P279
[9]   Novel PVC-based membrane sensors selective for vanadyl ions [J].
Jain, AK ;
Gupta, VK ;
Singh, LP ;
Khurana, U .
TALANTA, 1998, 46 (06) :1453-1460
[10]   Trapping of Cu2+ and VO2+ ions in conducting polymer matrices -: EPR studies [J].
Kudelski, A ;
Bukowska, J ;
Jackowska, K .
JOURNAL OF MOLECULAR STRUCTURE, 1999, 482 :291-294