Water compatible stir-bar devices imprinted with underivatised glyphosate for selective sample clean-up

被引:29
作者
Gomez-Caballero, Alberto [1 ]
Diaz-Diaz, Goretti [1 ]
Bengoetxea, Olatz [1 ]
Quintela, Amaia [1 ]
Unceta, Nora [1 ]
Aranzazu Goicolea, M. [1 ]
Barrio, Ramon J. [1 ]
机构
[1] Univ Basque Country, UPV EHU, Fac Pharm, Dept Analyt Chem, Vitoria 01006, Spain
关键词
Water compatible MIP; SBSE; Glyphosate; Soils; Natural waters; SOLID-PHASE EXTRACTION; AMINOMETHYL-PHOSPHONIC ACID; LIQUID-CHROMATOGRAPHY; GAS-CHROMATOGRAPHY; SPECTROMETRY; HERBICIDES; POLYMER; GLUFOSINATE; IMMUNOASSAY; METABOLITES;
D O I
10.1016/j.chroma.2016.05.017
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports the development of stir bars with a new MIP based coating, for the selective sorptive extraction of the herbicide glyphosate (GLYP). Molecular imprinting of the polymer has directly been carried out employing underivatised GLYP as the template molecule. Due to the poor solubility of the target compound in organic solvents, the MIP methodology has been optimised for rebinding in aqueous media, being the synthesis and the rebinding steps carried out in water:methanol mixtures and pure aqueous media. The coating has been developed by radical polymerisation initiated by UV energy, using N-allylthiourea and 2-dimethyl aminoethyl methacrylate as functional monomers and ethylene glycol dimethacrylate as the cross-linker. Mechanical stability of the coating has been improved using 1,3-divinyltetramethyldisiloxane in the polymerisation mixture. Under the optimised conditions, the MIP has demonstrated excellent selectivity for the target compound in the presence of structural analogues, including its major metabolites. The applicability of the proposed method to real matrices has also been assessed using river water and soil samples. Registered mean recoveries ranged from 90.6 to 97.3% and RSD values were below 5% in all cases, what confirmed the suitability of the described methodology for the selective extraction and quantification of GLYP. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:23 / 32
页数:10
相关论文
共 45 条
[11]  
Dong YL, 2015, ANAL METHODS-UK, V7, P5862, DOI [10.1039/c5ay00109a, 10.1039/C5AY00109A]
[12]   Evaluation of Titanium Dioxide as a Binding Phase for the Passive Sampling of Glyphosate and Aminomethyl Phosphonic Acid in an Aquatic Environment [J].
Fauvelle, Vincent ;
Tran-Thi Nhu-Trang ;
Feret, Thibaut ;
Madarassou, Karine ;
Randon, Jerome ;
Mazzella, Nicolas .
ANALYTICAL CHEMISTRY, 2015, 87 (12) :6004-6009
[13]   Chiral imprinted polymers as enantiospecific coatings of stir bar sorptive extraction devices [J].
Gomez-Caballero, Alberto ;
Guerreiro, Antonio ;
Karim, Kal ;
Piletsky, Sergey ;
Aranzazu Goicolea, M. ;
Barrio, Ramon J. .
BIOSENSORS & BIOELECTRONICS, 2011, 28 (01) :25-32
[14]  
Government of Canada, 1995, GUIDELINE TECHNICAL, V1, P1
[15]   Glyphosate-Based Herbicides Potently Affect Cardiovascular System in Mammals: Review of the Literature [J].
Gress, Steeve ;
Lemoine, Sandrine ;
Seralini, Gilles-Eric ;
Puddu, Paolo Emilio .
CARDIOVASCULAR TOXICOLOGY, 2015, 15 (02) :117-126
[16]   A simple method for the determination of glyphosate residues in soil by capillary gas chromatography with nitrogen phosphorus [J].
Hu, J. -Y. ;
Chen, C. -L. ;
Li, J. -Z. .
JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 63 (04) :371-375
[17]   Re-evaluation of glyphosate determination in water by liquid chromatography coupled to electrospray tandem mass spectrometry [J].
Ibanez, Maria ;
Pozo, Oscar J. ;
Sancho, Juan V. ;
Lopez, Francisco J. ;
Hernandez, Felix .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1134 (1-2) :51-55
[18]   Determination of glyphosate using off-line ion exchange preconcentration and capillary electrophoresis-laser induced fluorescence detection [J].
Jiang, Jiang ;
Lucy, Charles A. .
TALANTA, 2007, 72 (01) :113-118
[19]   Review of genotoxicity biomonitoring studies of glyphosate-based formulations [J].
Kier, Larry D. .
CRITICAL REVIEWS IN TOXICOLOGY, 2015, 45 (03) :209-218
[20]  
Kittlaus S, 2009, J AOAC INT, V92, P703