The Treatment of Proximal Humerus Fracture Using Internal Fixation With Fixed-angle Plates A Randomized Controlled Study Comparing Carbon Fiber Reinforced Polyetheretherketone With Titanium

被引:20
作者
Ziegler, Patrick [1 ]
Maier, Sven [1 ]
Stoeckle, Ulrich [2 ]
Guehring, Markus [3 ]
Stuby, Fabian M. [4 ]
机构
[1] Univ Tubingen, Univ Clin Trauma & Reconstruct Surg, Tubingen, Germany
[2] Charite Univ Med Ctr Berlin, Ctr Musculoskeletal Surg, Berlin, Germany
[3] Kronprinzenbau Hosp, Ctr Bone & Joint Surg, Reutlingen, Germany
[4] BG Hosp Murnau, Murnau, Germany
来源
DEUTSCHES ARZTEBLATT INTERNATIONAL | 2019年 / 116卷 / 45期
关键词
ANGULAR STABLE PLATE; SURGICAL-TREATMENT; ELDERLY-PATIENTS; OPEN REDUCTION; LOCKING PLATE; EPIDEMIOLOGY; COMPLICATIONS; MULTICENTER; STRATEGIES; IMPLANT;
D O I
10.3238/arztebl.2019.0757
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Implants made of various types of material can be used for the internal fixation of fractures. Carbon fiber reinforced polyetheretherketone (CFR-PEEK) is a radiolucent material that may have advantageous handling properties compared with titanium implants. Methods: Seventy-six patients with proximal humerus fractures requiring surgery were randomized to receive a fixed-angle plate made out of either titanium or CFR-PEEK. To measure the functional outcome, the DASH score (Disabilities of Arm. Shoulder, and Hand: primary endpoint). the Simple Shoulder Test (SST). and the Oxford Shoulder Score (OSS) were determined in 63 patients at 6 weeks, 12 weeks. and 6 months after surgery, accompanied at each time point by radiological evaluation. Results: Both groups displayed improvement in DASH scores 6 months after surgery (CFR-PEEK: 27.5 +/- 20.5: titanium: 28.5 +/- 17.9; p = 0.82). Sensitivity analysis with multiple imputations confirmed this result (27.4 +/- 19.2 versus 28.5 +/- 16.6). The OSS and SST scores were likewise improved in both groups. All patients displayed full bony consolidation 12 weeks after surgery. In no case was material failure, secondary dislocation, or screw perforation seen. No difference was seen in the maintenance of postoperative reposition between the CFR-PEEK group and the titanium group. Conclusion: The internal fixation of proximal humerus fractures with either CFR-PEEK or titanium led to clinical improvement 6 months after surgery. No clinical or radiological difference in outcomes was seen between the two groups. Because of the study design. however. the equivalence of the two interventions was not conclusively demonstrated; a non-inferiority study would have been needed for this purpose.
引用
收藏
页码:757 / +
页数:11
相关论文
共 35 条
  • [1] [Anonymous], 2017, AWMFNR012023
  • [2] Basic epidemiology of fractures of the upper and lower limb among Americans over 65 years of age
    Baron, JA
    Karagas, M
    Barrett, J
    Kniffin, W
    Malenka, D
    Mayor, M
    Keller, RB
    [J]. EPIDEMIOLOGY, 1996, 7 (06) : 612 - 618
  • [3] Trends and Variation in Incidence, Surgical Treatment, and Repeat Surgery of Proximal Humeral Fractures in the Elderly
    Bell, John-Erik
    Leung, Brian C.
    Spratt, Kevin F.
    Koval, Ken J.
    Weinstein, James D.
    Goodman, David C.
    Tosteson, Anna N. A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (02) : 121 - 131
  • [4] Open Reduction and Internal Fixation of Proximal Humerus Fractures Using a Proximal Humeral Locked Plate: A Prospective Multicenter Analysis
    Brunner, Felix
    Sommer, Christoph
    Bahrs, Christian
    Hettwinkel, Rainer
    Hafner, Christian
    Rillmann, Paavo
    Kohut, Georges
    Ekelund, Anders
    Muller, Mathias
    Audige, Laurent
    Babst, Reto
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (03) : 163 - 172
  • [5] The Treatment of Proximal Humeral Fracture in Adults
    Burkhart, Klaus J.
    Dietz, Sven O.
    Bastian, Leonard
    Thelen, Ulrich
    Hoffmann, Reinhard
    Mueller, Lars P.
    [J]. DEUTSCHES ARZTEBLATT INTERNATIONAL, 2013, 110 (35-36): : 591 - 597
  • [6] The effect of inferomedial screw on postoperative shoulder function and mechanical alignment in proximal humerus fractures
    Erdoğan M.
    Desteli E.E.
    İmren Y.
    Üztürk A.
    Kılıç M.
    Sezgin H.
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (7) : 1055 - 1059
  • [7] Displaced proximal humeral fractures: operative versus non-operative treatment—a 2-year extension of a randomized controlled trial
    Fjalestad T.
    Hole M.Ø.
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (7) : 1067 - 1073
  • [8] Surgical Treatment With an Angular Stable Plate for Complex Displaced Proximal Humeral Fractures in Elderly Patients: A Randomized Controlled Trial
    Fjalestad, Tore
    Hole, Margrethe O.
    Hovden, Inger Anette Hynas
    Blucher, Judith
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (02) : 98 - 106
  • [9] The importance of medial support in locked plating of proximal humerus fractures
    Gardner, Michael J.
    Weil, Yoram
    Barker, Joseph U.
    Kelly, Bryan T.
    Helfet, David L.
    Lorich, Dean G.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (03) : 185 - 191
  • [10] Removal of the Less Invasive Stabilization System
    Georgiadis, GM
    Gove, NK
    Smith, AD
    Rodway, IP
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) : 562 - 564