Investigation of angular smoothing of PET data

被引:9
作者
Daube-Witherspoon, ME [1 ]
Carson, RE [1 ]
机构
[1] NIH, Positron Emiss Tomog Dept, Warren Grant Magnuson Clin Ctr, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1109/23.656458
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Radial filtering of emission and transmission data is routinely performed in PET during reconstruction in order to reduce image noise. Angular smoothing is not typically done, due to the introduction of a non-uniform resolution loss. The goal of this paper was to assess the effects of angular smoothing on noise and resolution. Angular smoothing was incorporated into the reconstruction process on the Scanditronix PC2048-15B brain PET scanner. In-plane spatial resolution and noise reduction were measured for different amounts of radial and angular smoothing. For radial positions away from the center of the scanner, noise reduction and degraded tangential resolution with negligible loss of radial resolution were seen. Near the center, no resolution loss was observed, but there was also no reduction in noise even for large amounts of angular filtering. These results can be understood by recognizing that angular filtering is equivalent to a weighted sum of rotated images. We conclude that angular smoothing is not optimal due to its anisotropic noise reduction and resolution degradation properties.
引用
收藏
页码:2494 / 2499
页数:6
相关论文
共 10 条
[1]  
BEYER T, 1994, 1993 IEEE C REC NUCL, V3, P1422
[2]   STUDY ON THE USE OF TRANSMISSION SCANS FOR WHOLE-BODY PET ATTENUATION CORRECTION [J].
CHATZIIOANNOU, A ;
DAHLBOM, M ;
HOH, CJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1545-1550
[3]   Detailed investigation of transmission and emission data smoothing protocols and their effects on emission images [J].
Chatziioannou, A ;
Dahlbom, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (01) :290-294
[4]   PROBLEMS IN SIGNAL-TO-NOISE RATIO FOR ATTENUATION CORRECTION IN HIGH-RESOLUTION PET [J].
DAHLBOM, M ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) :288-293
[5]   PERFORMANCE EVALUATION OF THE PC-2048 - A NEW 15-SLICE ENCODED-CRYSTAL PET SCANNER FOR NEUROLOGICAL STUDIES [J].
EVANS, AC ;
THOMPSON, CJ ;
MARRETT, S ;
MEYER, E ;
MAZZA, M .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (01) :90-98
[6]  
Freedman NMT, 1996, J NUCL MED, V37, P690
[7]   EVALUATION OF THE KAROLINSKA NEW POSITRON CAMERA SYSTEM - THE SCANDITRONIX PC2048-15B [J].
LITTON, JE ;
HOLTE, S ;
ERIKSSON, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :743-748
[8]  
MEIKLE SR, 1993, J NUCL MED, V34, P143
[9]   TRANSMISSION PROFILE FILTERING FOR POSITRON EMISSION TOMOGRAPHY [J].
PALMER, MR ;
ROGERS, JG ;
BERGSTROM, M ;
BEDDOES, MP ;
PATE, BD .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :478-481
[10]  
STEARNS CW, 1995, 1994 IEEE C REC NUCL, V3, P1332