Safety and accuracy of robot-assisted placement of pedicle screws compared to conventional free-hand technique: a systematic review and meta-analysis

被引:98
作者
Fatima, Nida [1 ]
Massaad, Elie [1 ]
Hadzipasic, Muhamed [1 ]
Shankar, Ganesh M. [1 ]
Shin, John H. [1 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Neurosurg, Boston, MA 02115 USA
关键词
Artificial intelligence; Augmented realit; Efficacy; Pedicle screw; Robotics; Safety; Spine fusion; LUMBAR SPINE; INSERTION; GUIDANCE; SURGERY;
D O I
10.1016/j.spinee.2020.09.007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: The introduction and integration of robot technology into modern spine surgery provides surgeons with millimeter accuracy for pedicle screw placement. Coupled with computer-based navigation platforms, robot-assisted spine surgery utilizes augmented reality to potentially improve the safety profile of instrumentation. PURPOSE: In this study, the authors seek to determine the safety and efficacy of robotic-assisted pedicle screw placement compared to conventional free-hand (FH) technique. STUDY DESIGN/SETTING: We conducted a systematic review of the electronic databases using different MeSH terms from 1980 to 2020. OUTCOME MEASURES: The present study measures pedicle screw accuracy, complication rates, proximal-facet joint violation, intraoperative radiation time, radiation dosage, and length of surgery. RESULTS: A total of 1,525 patients (7,379 pedicle screws) from 19 studies with 777 patients (51.0% with 3,684 pedicle screws) in the robotic-assisted group were included. Perfect pedicle screw accuracy, as categorized by Gerztbein-Robbin Grade A, was significantly superior with robotic-assisted surgery compared to FH-technique (Odds ratio [OR]: 1.68, 95% confidence interval [CI]: 1.20-2.35; p=.003). Similarly, clinically acceptable pedicle screw accuracy (Grade A+B) was significantly higher with robotic-assisted surgery versus FH-technique (OR: 1.54, 95% CI: 1.01-2.37; p=.05). Furthermore, the complication rates and proximal-facet joint violation were 69% (OR: 0.31, 95% CI: 0.20-0.48; p<.00001) and 92% less likely (OR: 0.08, 95% CI: 0.03 -0.20; p<.00001) with robotic-assisted surgery versus FH-group. Robotic-assisted pedicle screw implantation significantly reduced intraoperative radiation time (MD: -5.30, 95% CI: -6.83 -3.76; p<.00001) and radiation dosage (MD: -3.70, 95% CI: -4.80-2.60; p<.00001) compared to the conventional FH-group. However, the length of surgery was significantly higher with robotic-assisted surgery (MD: 22.70, 95% CI: 6.57-38.83; p=.006) compared to the FH-group. CONCLUSION: This meta-analysis corroborates the accuracy of robot-assisted pedicle screw placement. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:181 / 192
页数:12
相关论文
共 51 条
[1]  
[Anonymous], 2013, Cochrane Consumers and Communication Review Group: Data synthesis and analysis, DOI DOI 10.26181/5B57D95632A2C
[2]  
Atkins D., 2004, Bmj, V328, P1490, DOI [10.1136/bmj.328.7454.1490, DOI 10.1136/BMJ.328.7454.1490]
[3]   Robotic assisted spine surgery - a breakthrough or a surgical toy? [J].
Barzilay, Y. ;
Kaplan, L. ;
Libergall, M. .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2008, 4 (03) :195-196
[4]   The da Vinci Robotic Surgical Assisted Anterior Lumbar Interbody Fusion Technical Development and Case Report [J].
Beutler, William J. ;
Peppelman, Walter C., Jr. ;
DiMarco, Luciano A. .
SPINE, 2013, 38 (04) :356-363
[5]   Evaluating the Accuracy of Robotic Assistance in Spine Surgery [J].
Cahill, K. S. ;
Wang, M. Y. .
NEUROSURGERY, 2012, 71 (02) :N20-N21
[6]  
Cannestra AF, 2014, SPINE J, V14, pS171, DOI 10.1016/j.spinee.2014.08.412.
[7]   Accuracy of pedicle screw placement in lumbar vertebrae [J].
Castro, WHM ;
Halm, H ;
Jerosch, J ;
Malms, J ;
Steinbeck, J ;
Blasius, S .
SPINE, 1996, 21 (11) :1320-1324
[8]   Combining C-arm CT with a new remote operated positioning and guidance system for guidance of minimally invasive spine interventions [J].
Czerny, Christoph ;
Eichler, Katrin ;
Croissant, Yann ;
Schulz, Boris ;
Kronreif, Gernot ;
Schmidt, Renate ;
von Roden, Martin ;
Schomerus, Christof ;
Vogl, Thomas J. ;
Marzi, Ingo ;
Zangos, Stephan .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (04) :303-308
[9]   Trim and fill: A simple funnel-plot-based method of testing and adjusting for publication bias in meta-analysis [J].
Duval, S ;
Tweedie, R .
BIOMETRICS, 2000, 56 (02) :455-463
[10]   Robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis of randomized controlled trials [J].
Gao, Shutao ;
Lv, Zhengtao ;
Fang, Huang .
EUROPEAN SPINE JOURNAL, 2018, 27 (04) :921-930