Clinical Outcomes and Cataract Formation Rates in Eyes 10 Years After Posterior Phakic Lens Implantation for Myopia

被引:104
作者
Guber, Ivo [1 ]
Mouvet, Victoria [1 ]
Bergin, Ciara [1 ]
Perritaz, Sylvie [1 ]
Othenin-Girard, Philippe [1 ]
Majo, Francois [1 ]
机构
[1] Univ Lausanne, Dept Ophthalmol, Jules Gonin Eye Hosp, Fdn Asile Aveugles, Ave France 15, CH-1000 Lausanne, Switzerland
关键词
INTRAOCULAR-LENS; COLLAMER LENS; CONTACT-LENS; FOLLOW-UP; MODERATE; SURGERY; EXTRACTION; OPACITIES; ICL;
D O I
10.1001/jamaophthalmol.2016.0078
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
IMPORTANCE Intraocular collamer lenses (ICLs) are posterior chamber phakic lenses that provide a refractive surgery option for those with high myopia or astigmatism. The short-term and midterm results indicate good refraction stability, efficacy, and safety. Cataract has been suggested to be an important long-term complication of ICL implantation. OBJECTIVE To report the rates of cataract development and refractive outcomes 10 years after ICL implantation. DESIGN, SETTING, AND PARTICIPANTS The study included 133 eyes of 78 patients undergoing consecutive V4 model ICL implantations, which took place from January 1, 1998, through December 31, 2004, at Jules-Gonin Eye Hospital, Lausanne, Switzerland. Data analysis was performed from January 1, 2014, to May 31, 2014. The lenses implanted were as follows: 53 V4 model ICLs of -15.5 D or greater, 73 V4 model ICLs of less than -15.5 diopter (D), and 7 V4 model toric ICLs for myopia. MAIN OUTCOMES AND MEASURES Rate of cataract surgery, lens opacity, ocular hypertension, refractive safety, predictability, and stability. RESULTS A total of 133 eyes of 78 patients (34 men and 44 women, with a mean [SD] age of 38.8 [9.2] years at enrollment) met the inclusion criteria. The rate of lens opacity development was 40.9%(95% CI, 32.7%-48.8%) and 54.8% (95% CI, 44.7%-63.0%) at 5 and 10 years, respectively. Phacoemulsification was performed in 5 eyes (4.9%; 95% CI, 1.0%-8.7%) and 18 eyes (18.3%; 95% CI, 10.1%-25.8%) at 5 and 10 years after ICL implantation, respectively. The vault height (distance between the posterior ICL surface and anterior lens surface) measured a mean (SD) of 426 (344) mu m immediately postoperatively, decreasing to 213 (169) mu m at 10 years. A smaller vault height was associated with the development of lens opacity and phacoemulsification (P = .005 and .008, respectively). The intraocular pressure was 15 mm Hg postoperatively, and there was no significant increase in intraocular pressure observed until the 10-year follow-up (16 mm Hg, P = .02). At 10 years, 12 eyes (12.9%; 95% CI, 5.6%-19.6%) had developed ocular hypertension that required topical medication. At 10 years, the mean (SD) safety index was 1.25 (0.57), with a manifest spherical equivalent of -0.5 D at 1-year postoperatively vs -0.7 D at 10 years postoperatively in eyes aimed at emmetropia. CONCLUSIONS AND RELEVANCE This retrospective single center study indicates that ICL implantation provides good long-term safety and stability of refraction in patients with high myopia compared with similar short-term studies. However, the rates of cataract formation and ocular hypertension at 10 years have important clinical implications, and as such this information should be part of the available patient information before ICL implantation.
引用
收藏
页码:487 / 494
页数:8
相关论文
共 34 条
[1]   Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: Five-year follow-up [J].
Alfonso, Jose F. ;
Baamonde, Begona ;
Fernandez-Vega, Luis ;
Fernandes, Paulo ;
Gonzalez-Meijome, Jose M. ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05) :873-880
[2]   Three-year follow-up of subjective vault following myopic implantable collamer lens implantation [J].
Alfonso, Jose F. ;
Lisa, Carlos ;
Abdelhamid, A. ;
Fernandes, Paulo ;
Jorge, Jorge ;
Montes-Mico, Robert .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (12) :1827-1835
[3]   Angle-supported anterior chamber phakic intraocular lens explantation -: Causes and outcome [J].
Alio, Jorge L. ;
Abdelrahman, Ayman M. ;
Javaloy, Jaime ;
Iradier, Maria Teresa ;
Ortuno, Vicente .
OPHTHALMOLOGY, 2006, 113 (12) :2213-2220
[4]   World Medical Association Declaration of Helsinki Ethical Principles for Medical Research Involving Human Subjects [J].
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2013, 310 (20) :2191-2194
[5]   Phakic posterior chamber lenses for high myopia: Functional and anatomical outcomes [J].
Arne, JL ;
Lesueur, LC .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (03) :369-374
[6]   Effect of cataract surgery on the corneal endothelium - Modern phacoemulsification compared with extracapsular cataract surgery [J].
Bourne, RRA ;
Minassian, DC ;
Dart, JKG ;
Rosen, P ;
Kaushal, S ;
Wingate, N .
OPHTHALMOLOGY, 2004, 111 (04) :679-685
[7]   Changes in Iridocorneal Angle Structure and Trabecular Pigmentation With STAAR Implantable Collamer Lens During 2 Years [J].
Chung, Tae-Young ;
Park, Sung Chul ;
Lee, Myoung Ok ;
Ahn, Kyeon ;
Chung, Eui-Sang .
JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (03) :251-258
[8]   Long-term endothelial changes in phakic eyes with posterior chamber intraocular lenses [J].
Dejaco-Ruhswurm, I ;
Scholz, U ;
Pieh, S ;
Hanselmayer, G ;
Lackner, B ;
Italon, C ;
Ploner, M ;
Skorpik, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (09) :1589-1593
[9]   Endothelial damage with cataract surgery techniques [J].
Diaz-Valle, D ;
Sanchez, JMBD ;
Castillo, A ;
Sayagues, O ;
Moriche, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (07) :951-955
[10]   Corneal endothelial assessment after ICL implantation [J].
Edelhauser, HF ;
Sanders, DR ;
Azar, R ;
Lamielle, H .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (03) :576-583