Separation of uranium(VI) and lanthanides by capillary electrophoresis using on-capillary complexation with arsenate III

被引:79
作者
Macka, M [1 ]
Nesterenko, P [1 ]
Andersson, P [1 ]
Haddad, PR [1 ]
机构
[1] Univ Tasmania, Dept Chem, Hobart, Tas 7001, Australia
基金
澳大利亚研究理事会;
关键词
complexation; background electrolyte composition; uranium; lanthanides; arsenazo III;
D O I
10.1016/S0021-9673(97)01226-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The viability of the separation of lanthanides and uranium(VI) in the form of strongly absorbing complexes with arsenate III (AIII) was studied with the aim to increase the sensitivity of absorbance detection in determination of these metals by capillary electrophoresis (CE). Special attention was paid to the complexation equilibria in the background electrolyte (BGE). On-capillary complexation provided better peak shapes for lanthanides compared to pre-column complexation. While the BGE composition had very little effect on the peak shape of the kinetically inert uranium(VI) complex, it played a crucial role in the peak shapes of the kinetically labile lanthanide complexes. Addition of a second ligand competing with the metallochromic ligand AIII for the metal ions was found to be critical to achieve good peak shape. The nature and concentration of the competing complexing ligand added to the BGE, the pH, and the concentration of AIII were found to exert a strong influence on the separation selectivity, peak shapes and the detection sensitivity. Several carboxylic acids were compared as BGE competing ligands and citrate provided best selectivity and peak shapes. A citrate BGE at pH 4.7 and containing 0.1 mM AIII was used for the separation of uranium(VI) (350 000 theoretical plates) and La-III (63 000 theoretical plates) while, to separate most lanthanides and uranium(VI), a similar BGE with a lower (0.03 mM) AIII concentration was used. Using hydrostatic sampling (100 mm for 10 a) detection limits of 0.35 mu M (49 ppb) La-III and 25 mu M (60 ppb) UO2 were obtained. Using on-capillary complexation, sample stacking was retained for injection times of up to at least 100 s (ca. 30-mm sample plug) without loss of peak shapes for lanthanides or recovery for La-III. When this process was used, the detection limit for La-III was reduced to about 5 ppb. Optimal properties of metallochromic ligands for separation and detection of metals by CE are discussed. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:279 / 290
页数:12
相关论文
共 56 条
[51]   CAPILLARY ZONE ELECTROPHORESIS OF LANTHANOID ELEMENTS AFTER COMPLEXATION WITH AMINOPOLYCARBOXYLIC ACIDS [J].
TIMERBAEV, AR ;
SEMENOVA, OP ;
BONN, GK .
ANALYST, 1994, 119 (12) :2795-2799
[52]   METAL-ION CAPILLARY ELECTROPHORESIS WITH DIRECT UV DETECTION EFFECT OF A CHARGED SURFACTANT ON THE MIGRATION BEHAVIOR OF METAL-CHELATES [J].
TIMERBAEV, AR ;
SEMENOVA, OP ;
JANDIK, P ;
BONN, GK .
JOURNAL OF CHROMATOGRAPHY A, 1994, 671 (1-2) :419-427
[53]   COMPLEX EQUILIBRIA IN CAPILLARY ZONE ELECTROPHORESIS AND THEIR USE FOR THE SEPARATION OF RARE-EARTH-METAL IONS [J].
VOGT, C ;
CONRADI, S .
ANALYTICA CHIMICA ACTA, 1994, 294 (02) :145-153
[54]   FACTORS AFFECTING THE SEPARATION OF INORGANIC METAL-CATIONS BY CAPILLARY ELECTROPHORESIS [J].
WESTON, A ;
BROWN, PR ;
JANDIK, P ;
JONES, WR ;
HECKENBERG, AL .
JOURNAL OF CHROMATOGRAPHY, 1992, 593 (1-2) :289-295
[55]  
[No title captured]
[56]  
1994, DIONEX TECH, V91, P1