Patient preference and ease of use for different coagulation factor VIII reconstitution device scenarios: a cross-sectional survey in five European countries

被引:15
作者
Cimino, Ernesto [1 ]
Linari, Silvia [2 ]
Malerba, Mara [3 ]
Halimeh, Susan [4 ]
Biondo, Francesca [5 ]
Westfeld, Martina [5 ]
机构
[1] Univ Naples Federico II, Dipartimento Med Clin & Sperimentale, I-80131 Naples, Italy
[2] AOU Careggi Firenze, Agenzia Emofilia, Florence, Italy
[3] Fdn Ca Granda Osped Maggiore Policlin, Ctr Emofilia & Trombosi A Bianchi Bonomi, Milan, Italy
[4] CRC Coagulat Res Ctr GmbH, Duisburg, Germany
[5] Pfizer Italia, Rome, Italy
关键词
hemophilia; factor VIII; patient preference; reconstitution; dual-chamber syringe; QUALITY-OF-LIFE; HEMOPHILIA TREATMENT;
D O I
10.2147/PPA.S64709
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Hemophilia A treatment involves replacing the deficient coagulation factor VIII. This process may involve multiple steps that might create a barrier to adherence. A new dual-chamber syringe (DCS; FuseNGo (R)) was recently introduced with the aim of simplifying reconstitution. Aim: This study aimed to identify factors associated with adult patients' preferences for different coagulation factor VIII reconstitution systems and to test ease of use and patient preference for the DCS. Methods: A cross-sectional survey of adults with hemophilia A in five European countries was conducted; a subset of subjects also participated in a practical testing session of the DCS. Results: Among the 299 survey participants, the device scenario requiring the least equipment and reconstitution steps (the DCS) received a median preference rating of 71 out of 100 (0 being "the least desirable" and 100 "the most desirable" rating). This was significantly higher than the other scenarios (the next highest achieved a median of 50 points; P < 0.001). Participants would be more likely to use this device prophylactically (P < 0.001). Among the 98 participants who tested the DCS, 57% preferred this device over their current device, 26% preferred their current device, and 17% had no preference. The DCS was rated as easier to use than current treatment devices (median score 9/10 versus 7/10 for current treatment, P = 0.001). Conclusion: The survey indicates that the prefilled DCS, FuseNGo (R), requiring the least equipment and fewest reconstitution steps, was preferred by patients and was the device most likely to be used prophylactically; the practical device testing supports these results.
引用
收藏
页码:1713 / 1720
页数:8
相关论文
共 19 条
[1]   THE THEORY OF PLANNED BEHAVIOR [J].
AJZEN, I .
ORGANIZATIONAL BEHAVIOR AND HUMAN DECISION PROCESSES, 1991, 50 (02) :179-211
[2]  
[Anonymous], GUID MAN HAEM
[3]   An exploration of health-related quality of life in adults with haemophilia - a qualitative perspective [J].
Beeton, K ;
Neal, D ;
Lee, C .
HAEMOPHILIA, 2005, 11 (02) :123-132
[4]  
Carr AJ, 2004, RHEUMATOLOGY, V43, P83
[5]   Factor VIII requirement to maintain a target plasma level in the prophylactic treatment of severe hemophilia A: influences of variance in pharmacokinetics and treatment regimens [J].
Collins, P. W. ;
Bjorkman, S. ;
Fischer, K. ;
Blanchette, V. ;
Oh, M. ;
Schroth, P. ;
Fritsch, S. ;
Casey, K. ;
Spotts, G. ;
Ewenstein, B. M. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2010, 8 (02) :269-275
[6]  
European Medicines Agency, 2012, SUMM PROD CHAR REFAC
[7]  
Fletcher M, 1997, HAEMOPHILIA OTHER IN
[8]   Barriers to compliance with prophylaxis therapy in haemophilia [J].
Hacker, MR ;
Geraghty, S ;
Manco-Johnson, M .
HAEMOPHILIA, 2001, 7 (04) :392-396
[9]  
Miners AH, 1999, HAEMOPHILIA, V5, P378
[10]  
Musso R, 2010, INT J GEN MED, V3, P203