Rupture of the external iliac artery during balloon angioplasty: Endovascular treatment using a covered stent

被引:0
作者
Formichi, M [1 ]
Raybaud, G [1 ]
Benichou, H [1 ]
Ciosi, G [1 ]
机构
[1] Clin Bouchard, F-13006 Marseille, France
来源
JOURNAL OF ENDOVASCULAR SURGERY | 1998年 / 5卷 / 01期
关键词
stent-grafts; endografts; covered stents; angioplasty complications; Cragg EndoPro System 1;
D O I
10.1583/1074-6218(1998)005<0037:ROTEIA>2.0.CO;2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To report the emergent endovascular management of an external iliac artery (EIA) rupture after standard guidewire recanalization and balloon angioplasty. Method and Results: A 54-year-old diabetic male presented with an occlusion of the EIA associated with severe stenotic lesions of the femoral bifurcation. Guidewire recanalization of the lumen was followed by balloon angioplasty, but evidence of EIA ru ptu re was detected on the intraoperative arteriogram. Temporary homeostasis was achieved using the angioplasty balloon, and a Cragg EndoPro System 1 stent-graft was inserted transluminally to repair the injury. At 18 months poststenting, routine color Doppler confirmed continued patency of the vessel repair. Conclusions: While rupture of the EIA during angioplasty usually demands open surgical correction, an endovascular procedure can provide a fast, efficient, and less aggressive method of treating this serious complication.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 14 条
  • [1] THE DEVELOPMENT OF AN INFECTED FALSE ANEURYSM FOLLOWING ILIAC ANGIOPLASTY
    COOPER, JC
    WOODS, DA
    SPENCER, P
    PROCTER, AE
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (764) : 759 - 760
  • [2] DIETHRICH EB, 1995, J ENDOVASC SURG, V2, P225, DOI 10.1583/1074-6218(1995)002<0225:EGFAAO>2.0.CO
  • [3] 2
  • [4] FORMICHI MJ, 1996, J ENDOVASC SURG, V3, P461
  • [5] 5-YEAR RESULTS OF A PROSPECTIVE-STUDY OF PERCUTANEOUS TRANS-LUMINAL ANGIOPLASTY
    JOHNSTON, KW
    RAE, M
    HOGGJOHNSTON, SA
    COLAPINTO, RF
    WALKER, PM
    BAIRD, RJ
    SNIDERMAN, KW
    KALMAN, P
    [J]. ANNALS OF SURGERY, 1987, 206 (04) : 403 - 413
  • [6] TRANSLUMINALLY PLACED ENDOVASCULAR STENTED GRAFT REPAIR FOR ARTERIAL TRAUMA
    MARIN, ML
    VEITH, FJ
    PANETTA, TF
    CYNAMON, J
    SANCHEZ, LA
    SCHWARTZ, ML
    LYON, RT
    BAKAL, CW
    SUGGS, WD
    [J]. JOURNAL OF VASCULAR SURGERY, 1994, 20 (03) : 466 - 473
  • [7] PERCUTANEOUS TRANSFEMORAL INSERTION OF A STENTED GRAFT TO REPAIR A TRAUMATIC FEMORAL ARTERIOVENOUS-FISTULA
    MARIN, ML
    VEITH, FJ
    PANETTA, TF
    CYNAMON, J
    BARONE, H
    SCHONHOLZ, C
    PARODI, JC
    [J]. JOURNAL OF VASCULAR SURGERY, 1993, 18 (02) : 299 - 302
  • [9] LONG ILIAC STENOSIS - INITIAL CLINICAL-EXPERIENCE WITH THE CRAGG ENDOLUMINAL GRAFT
    PERNES, JM
    AUGUSTE, MA
    HOVASSE, D
    GIGNIER, P
    LASRY, B
    LASRY, JL
    [J]. RADIOLOGY, 1995, 196 (01) : 67 - 71
  • [10] SCHUBART PJ, 1985, COMPLICATIONS VASCUL, P87