Ways to Improve the Analytical Characteristics of Magnetic-Sector Time-of-Flight Mass Analyzers

被引:0
|
作者
Nuriev, K. Z. [1 ]
Nurubeyli, T. K. [1 ]
Nurubeyli, Z. K. [1 ]
机构
[1] Natl Acad Sci Azerbaijan, Inst Phys, Baku 1143, Azerbaijan
关键词
CHARGE;
D O I
10.1134/S1063785009120244
中图分类号
O59 [应用物理学];
学科分类号
摘要
Ways to improve the characteristics of analyzers and the parameters of ion beams in magnetic-sector time-of-flight mass spectrometers with axisymmetric electrostatic fields are considered. It is shown that the analyzer transmission can be improved by eliminating the edge effects at the analyzer entrance and exit. The limiting ion current through the analyzer is determined, above which the mass resolution decreases by an order of magnitude. A new method is proposed for compensating for the intrinsic space charge of ions. Necessary requirements for the precision of manufacturing mass analyzers are refined.
引用
收藏
页码:1156 / 1159
页数:4
相关论文
共 50 条
  • [21] AN AUTOMATED MAGNETIC-SECTOR MASS-SPECTROMETER
    BRUNNEE, C
    JUNG, G
    MARKWARDT, U
    PESCH, R
    WOLLNIK, H
    AMERICAN LABORATORY, 1986, 18 (11) : 102 - &
  • [22] COMPARATIVE TESTS OF QUADRUPOLE, MAGNETIC, AND TIME-OF-FLIGHT RESIDUAL-GAS ANALYZERS
    ABBOTT, PJJ
    KENDALL, BRF
    TROUT, KP
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1991, 9 (03): : 1996 - 2000
  • [23] NEUTRAL-ION CORRELATION-MEASUREMENTS - A NOVEL TANDEM MASS-SPECTROMETRY DATA ACQUISITION MODE FOR TANDEM MAGNETIC-SECTOR REFLECTRON TIME-OF-FLIGHT INSTRUMENTS
    STROBEL, FH
    PRESTON, LM
    WASHBURN, KS
    RUSSELL, DH
    ANALYTICAL CHEMISTRY, 1992, 64 (07) : 754 - 762
  • [24] Mass measurement accuracy comparisons between a double-focusing magnetic sector and a time-of-flight mass analyzer
    Bereman, Michael S.
    Lyndon, Matthew M.
    Dixon, R. Brent
    Muddiman, David C.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (10) : 1563 - 1566
  • [25] A NEW GENERATION OF HIGH-PERFORMANCE MASS SPECTROMETERS FOR ENVIRONMENTAL CHEMISTRY - TANDEM MAGNETIC-SECTOR TIME-OF-FLIGHT AND FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE
    RUSSELL, DH
    LEWIS, TM
    SOLOUKI, T
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 64 - ANYL
  • [26] VERSATILE MASS READOUT SYSTEM FOR MAGNETIC-SECTOR MASS SPECTROMETERS
    BELL, J
    CHUNG, A
    GARNETT, JL
    GREGOR, IK
    GUILHAUS, M
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1979, 12 (08): : 683 - 685
  • [27] OPTIMIZATION OF THE ANALYTICAL PERFORMANCE OF THE MAGNETIC-SECTOR MASS-SPECTROMETER FOR THE IDENTIFICATION OF RESIDUAL CHLORAMPHENICOL IN SHRIMP
    BENCSATH, FA
    PLAKAS, SM
    LONG, AR
    BIOLOGICAL MASS SPECTROMETRY, 1994, 23 (11) : 665 - 674
  • [28] Pseudorandom time-of-flight analysis with a time-of-flight mass spectrometer
    Bewig, L
    Buck, U
    Gandhi, SR
    Winter, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (02): : 417 - 422
  • [29] Physical signal modulation of time-of-flight mass analyzers increases precision and decreases noise
    Hilmer, Jonathan K.
    Bothner, Brian
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (06) : 795 - 805
  • [30] THE EXPANDING ROLE OF TIME-OF-FLIGHT MASS SPECTROMETERS IN ANALYTICAL MASS-SPECTROMETRY
    RUSSELL, DH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 210 : 113 - ANYL