Precision of the measurements of periprosthetic bone mineral density in hips with a custom-made femoral stem

被引:48
作者
Martini, F [1 ]
Lebherz, C [1 ]
Mayer, F [1 ]
Leichtle, U [1 ]
Kremling, E [1 ]
Sell, S [1 ]
机构
[1] Univ Tubingen Hosp, Dept Sports Med, D-72076 Tubingen, Germany
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2000年 / 82B卷 / 07期
关键词
D O I
10.1302/0301-620X.82B7.9791
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Our aim was to determine the precision of the measurements of bone mineral density (BMD) by dual-energy x-ray absorptiometry in the proximal femur before and after implantation of an uncemented implant, with particular regard to the significance of retro- and prospective studies. We examined 60 patients to determine the difference in preoperative BMD between osteoarthritic and healthy hips. The results showed a preoperative BMD of the affected hip which was lower by a mean of 4% and by a maximum of 9% compared with the opposite side. In addition, measurements were made in the operated hip before and at ten days after operation to determine the effect of the implantation of an uncemented custom-made femoral stem. The mean increase in the BMD was 8% and the maximum was 24%, Previous retrospective studies have reported a marked loss of BMD on the operated side. The precision of double measurements using a special foot jig showed a modified coefficient of variation of 0.6% for the non-operated side in 15 patients and of 0.6% for the operated femur in 20 patients. The effect of rotation on the precision of the measurements after implantation of an uncemented femoral stem was determined in ten explanted femora and for the operated side in ten patients at 10 degrees rotation and in 20 patients at 30 degrees rotation, Rotation within 30 degrees influenced the precision in studies in vivo and in vitro by a mean of 3% and in single cases in up to 60%. Precise prediction of the degree of loss of BMD is thus only possible in prospective cross-sectional measurements, since the effect of the difference in preoperative BMD, as well as the apparent increase in BMD after implantation of an uncemented stem, is not known from retrospective studies, The DEXA method is a reliable procedure for determining periprosthetic BMD when positioning and rotation are strictly controlled.
引用
收藏
页码:1065 / 1071
页数:7
相关论文
共 25 条
[1]   BONE AND MUSCLE MASS AFTER HIP-ARTHROPLASTY - A QUANTITATIVE COMPUTED-TOMOGRAPHY STUDY IN 20 ARTHROSIS CASES [J].
ADOLPHSON, P ;
VONSIVERS, K ;
DALEN, N ;
JONSSON, U ;
DAHLBORN, M .
ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (02) :181-184
[2]  
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[3]  
CHECOVICH MM, 1991, IOWA ORTHOPAEDIC J, V15, P62
[4]   ACCURACY OF DEXA MEASUREMENT OF BONE-MINERAL DENSITY AFTER TOTAL HIP-ARTHROPLASTY [J].
COHEN, B ;
RUSHTON, N .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (03) :479-483
[5]  
DICKOB M, 1993, OSTEOLOGIE, V2, P206
[6]   EFFECT OF FEMORAL ROTATION ON BONE-MINERAL DENSITY-MEASUREMENTS WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY [J].
GOH, JCH ;
LOW, SL ;
BOSE, K .
CALCIFIED TISSUE INTERNATIONAL, 1995, 57 (05) :340-343
[7]  
HALL ML, 1991, EUR J NUCL MED, V18, P38
[8]   DUAL-ENERGY X-RAY ABSORPTIOMETRY MEASUREMENT OF BONE-MINERAL DENSITY AROUND POROUS-COATED CEMENTLESS FEMORAL IMPLANTS - METHODS AND PRELIMINARY-RESULTS [J].
KILGUS, DJ ;
SHIMAOKA, EE ;
TIPTON, JS ;
EBERLE, RW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :279-287
[9]   DETERMINATION OF BONE-MINERAL DENSITY BY DUAL X-RAY ABSORPTIOMETRY IN PATIENTS WITH UNCEMENTED TOTAL HIP-ARTHROPLASTY [J].
KIRATLI, BJ ;
HEINER, JP ;
MCBEATH, AA ;
WILSON, MA .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (06) :836-844
[10]  
KOROVESSIS P, 1994, CLIN ORTHOP RELAT R, V309, P214