Investigation of electrocoagulation reactor design parameters effect on the removal of cadmium from synthetic and phosphate industrial wastewater

被引:124
作者
Brahmi, Khaled [1 ]
Bouguerra, Wided [1 ]
Hamrouni, Bechir [1 ]
Elaloui, Elimame [2 ]
Loungou, Mouna [3 ]
Tlili, Zied [4 ]
机构
[1] Fac Sci Tunis, Dept Chim, UR Traitement & Dessalement Eaux, Manar 2092 2, Tunisia
[2] Fac Sci Gafsa, Dept Chim, UR Mat Environm & Energie, Campus Univ Sidi Ahmed Zarroug, Gafsa 2112, Tunisia
[3] Usine MDhilla Gafsa, Grp Chim Tunisien, Km 14 Route MDhilla, Gafsa 2100, Tunisia
[4] Higher Inst Business Adm Gafsa, Campus Univ Sidi Ahmed Zarroug, Gafsa 2112, Tunisia
关键词
Wastewater treatment; Electrocoagulation; Treatment cost; Investigation of reactor design parameters; Cadmium removal; Energy consumption; ALUMINUM; DEFLUORIDATION; SEPARATION; LEACHATE; METALS;
D O I
10.1016/j.arabjc.2014.12.012
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study investigates the effect of reactor design parameters on cadmium removal from industrial wastewater discharged by the Tunisian Chemical Group (TCG) to improve as much as possible efficiency and cost of electrocoagulation (EC) process. Based on an examination of the design parameters one by one, the best cadmium removal was achieved for an inter-electrode distance (d(ie)) of 0.5 cm, monopolar connection mode, stirring speed of 300 rev min(-1), surface-area-to-volume ratio (S/V) of 13.6 m(-1), and an initial temperature of 50 degrees C. These operating conditions are allowed to achieve efficient removal in a relatively short operating time with the lowest energy consumption and cost possible. The present study proved that the parameters that have an effect on the operating cost are the electrode configuration, inter-electrode distance and S/V ratio. The energy consumption, the pH evolution, and the treatment cost were studied. The investigation of the effect of all the selected optimum EC design parameters together on the removal of cadmium from the TCG wastewater proved that the treatment was highly efficient; 100% of cadmium removal was reached in 5 min, with a very low power consumption (1.6 kW h m(-3)) and very low cost (0.116 TND m(-3)). Moreover, EC was found to be capable of removing cadmium as well as other pollutants at the same time from the case-study industrial wastewater. The investigation carried out in this work explores and proposes a very cost-effective treatment method to remove heavy metals from industrial wastewater if compared to results reported about cost of this treatment process through other widely used technologies such as coagulation (4.36 Tunisian National Dinar (TND) m(-3)) and precipitation (9.96 TND m(-3)) employed in previous studies. (C) 2015 The Authors. Published by Elsevier B.V. on behalf of King Saud University. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:1848 / 1859
页数:12
相关论文
共 37 条
[1]   Treatment of the textile wastewater by electrocoagulation Economical evaluation [J].
Bayramoglu, Mahmut ;
Eyvaz, Murat ;
Kobya, Mehmet .
CHEMICAL ENGINEERING JOURNAL, 2007, 128 (2-3) :155-161
[2]   Electrolytic recovery of lead in used lime leachate from municipal waste incinerator [J].
Beauchesne, I ;
Meunier, N ;
Drogui, P ;
Hausler, R ;
Mercier, G ;
Blais, JF .
JOURNAL OF HAZARDOUS MATERIALS, 2005, 120 (1-3) :201-211
[3]   Electrochemical treatment of cigarette industry wastewater: feasibility study [J].
Bejankiwar, RS .
WATER RESEARCH, 2002, 36 (17) :4386-4390
[4]   Electrocoagulation of a raw water of Ghrib Dam (Algeria) in batch using aluminium and iron electrodes [J].
Belhout, Dalila ;
Ghernaout, Djamel ;
Djezzar-Douakh, Souad ;
Kellil, Amara .
DESALINATION AND WATER TREATMENT, 2010, 16 (1-3) :1-9
[5]   Electrochemical technologies in wastewater treatment [J].
Chen, GH .
SEPARATION AND PURIFICATION TECHNOLOGY, 2004, 38 (01) :11-41
[6]   Separation of pollutants from restaurant wastewater by electrocoagulation [J].
Chen, XM ;
Chen, GH ;
Yue, PL .
SEPARATION AND PURIFICATION TECHNOLOGY, 2000, 19 (1-2) :65-76
[7]  
Chopra A. K., 2011, Archives of Applied Science Research, V3, P191
[8]   Decolorization of basic dye solutions by electrocoagulation: An investigation of the effect of operational parameters [J].
Daneshvar, N ;
Oladegaragoze, A ;
Djafarzadeh, N .
JOURNAL OF HAZARDOUS MATERIALS, 2006, 129 (1-3) :116-122
[9]   An empirical model for defluoridation by batch monopolar electrocoagulation/flotation (ECF) process [J].
Emamjomeh, MM ;
Sivakumar, M .
JOURNAL OF HAZARDOUS MATERIALS, 2006, 131 (1-3) :118-125
[10]   Fluoride removal by a continuous flow electrocoagulation reactor [J].
Emamjomeh, Mohammad M. ;
Sivakumar, Muttucumaru .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2009, 90 (02) :1204-1212