Intraoperative contrast-enhanced ultrasonography for microcirculatory evaluation in rhesus monkey with spinal cord injury

被引:11
|
作者
Huang, Lin [1 ]
Chen, Keng [1 ]
Chen, Fu-Chao [1 ]
Shen, Hui-Yong [1 ]
Ye, Ji-Chao [1 ]
Cai, Zhao-Peng [1 ]
Lin, Xi [2 ]
机构
[1] Sun Yat Sen Univ, Mem Hosp, Dept Orthoped, Inst Spinal Cord Injury, Guangzhou 510120, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Dept Ultrasound, State Key Lab Oncol South China, Canc Ctr, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
spinal cord; contusion; perfusion; rhesus monkey; contrast-enhanced ultrasound; LASER-DOPPLER FLOWMETRY; CEREBRAL-BLOOD-FLOW; COMPRESSION; MODEL; CONTUSION; ISCHEMIA; TRAUMA; MOTOR; RATS;
D O I
10.18632/oncotarget.17252
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This study tried to quantify spinal cord perfusion by using contrast-enhanced ultrasound (CEUS) in rhesus monkey models with acute spinal cord injury. Acute spinal cord perfusion after injury was detected by CEUS, coupling with conventional ultrasound (US) and Color Doppler US (CDFI). Time-intensity curves and perfusion parameters were obtained by autotracking contrast quantification (ACQ) software in the epicenter and adjacent regions of injury, respectively. Neurological and histological examinations were performed to confirm the severity of injury. US revealed spinal cords were hypoechoic and homogeneous, whereas dura maters, pia maters, and cerebral aqueducts were hyperechoic. After spinal cord contusion, the injured spinal cord was hyperechoic on US, and intramedullary vessels of adjacent region of injury were increased and dilated on CDFI. On CEUS hypoperfusion were found in the epicenter of injury, while hyperperfusion in its adjacent region. Quantitative analysis showed that peak intensity (PI) decreased in epicenters of injury but significantly increased in adjacent regions at all time points (p < 0.05). Functional evaluation demonstrated significant deterioration compared to pre-contusion (p < 0.05). Quantitative analysis with CEUS is a promising method for monitoring perfusion changes of spinal cord injury in overall views and real-time.
引用
收藏
页码:40756 / 40764
页数:9
相关论文
共 50 条
  • [41] Contrast-enhanced ultrasonography of the pancreas in healthy cats
    Diana, Alessia
    Linta, Nikolina
    Cipone, Mario
    Fedone, Valeria
    Steiner, Joerg M.
    Fracassi, Federico
    Grandis, Annamaria
    BaronToaldo, Marco
    BMC VETERINARY RESEARCH, 2015, 11
  • [42] EFFECT OF SEDATION ON CONTRAST-ENHANCED ULTRASONOGRAPHY OF THE SPLEEN IN HEALTHY DOGS
    Rossi, Federica
    Fina, Caroline
    Stock, Emmelie
    Vanderperren, Katrien
    Duchateau, Luc
    Saunders, Jimmy H.
    VETERINARY RADIOLOGY & ULTRASOUND, 2016, 57 (03) : 276 - 281
  • [43] Gray-scale Contrast-enhanced Ultrasonography for Quantitative Evaluation of the Blood Perfusion of the Sciatic Nerves with Crush Injury
    Wang, Yuexiang
    Tang, Peifu
    Zhang, Lihai
    Wan, Wenbo
    He, Chunqing
    Tang, Jie
    ACADEMIC RADIOLOGY, 2011, 18 (10) : 1285 - 1291
  • [44] Benefits of contrast-enhanced ultrasonography for interventional procedures
    Marschner, Constantin Arndt
    Ruebenthaler, Johannes
    Froelich, Matthias Frank
    Schwarze, Vincent
    Clevert, Dirk-Andre
    ULTRASONOGRAPHY, 2021, 40 (02) : 207 - 216
  • [45] Comparison of contrast-enhanced ultrasonography and contrast-enhanced MRI for the assessment of vascularization of hydroxyapatite orbital implants
    Xu Qi-hua
    Zhao Chen
    Zhu Jian-gang
    Zou Da-zhong
    Zheng Yong-qiang
    CLINICAL IMAGING, 2014, 38 (05) : 616 - 620
  • [46] Contrast-enhanced ultrasonography (CEUS) - Clinical application
    Rychlik, Andrzej
    Wdowiak, Michal
    Nowicki, Marcin
    Nieradka, Renata
    Kander, Malgorzata
    MEDYCYNA WETERYNARYJNA-VETERINARY MEDICINE-SCIENCE AND PRACTICE, 2011, 67 (10): : 669 - 672
  • [47] Spinal Cord Injury of Rhesus Monkey Implanted with PPy/I Plasma Polymer, MRI Study
    Morales-Guadarrama, Axayacatl
    Salgado-Ceballos, Hermelinda
    Grijalva, Israel
    Morales, Juan
    Rios, Camilo
    Cruz, Guillermo J.
    Diaz-Ruiz, Araceli
    Olayo, Maria-Guadalupe
    Alvarez-Mejia, Laura
    Mondragon-Lozano, Rodrigo
    Ibanez-Contreras, Alejandra
    Hernandez-Godinez, Braulio
    Olayo, Roberto
    VI LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2014), 2014, 49 : 174 - 177
  • [48] Novel Contrast-Enhanced Ultrasound Evaluation in Neonatal Hypoxic Ischemic Injury: Clinical Application and Future Directions
    Hwang, Misun
    De Jong, Robert M., Jr.
    Herman, Stephan
    Boss, Renee
    Riggs, Becky
    Tekes-Brady, Aylin
    Spevak, Melissa
    Poretti, Andrea
    Soares, Bruno P.
    Bailey, Christopher R.
    Dunn, Emily
    Shin, Samuel S.
    Shrot, Shai
    Huisman, Thierry A. G. M.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (11) : 2379 - 2386
  • [49] Contrast-enhanced ultrasonography for evaluation of the blood perfusion of sciatic nerves in healthy dogs
    Lee, Juryeong
    Lee, Dongjae
    Suh, Guk-Hyun
    Choi, Jihye
    VETERINARY RADIOLOGY & ULTRASOUND, 2023, 64 (02) : 322 - 329
  • [50] Contrast-Enhanced Ultrasonography Characteristics in the Evaluation of Different Nature of Carotid Artery Plaques
    Li, Hongbo
    Huang, Hui
    Luan, Yun
    Liu, Niu
    Gao, Hui
    Sun, Huijuan
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2020, 10 (03) : 688 - 692