Design of a stable solid-contact ion-selective electrode based on polyaniline nanoparticles as ion-to-electron transducer for application in process analytical technology as a real-time analyzer

被引:38
作者
Abd El-Rahman, Mohamed K. [1 ]
Rezk, Mamdouh R. [1 ]
Mahmoud, Amr M. [1 ]
Elghobashy, Mohamed R. [1 ]
机构
[1] Cairo Univ, Fac Pharm, Dept Analyt Chem, ET-11562 Cairo, Egypt
关键词
Conducting polymers; Ion-to-electron transducers; Polyaniline nanoparticles; Process analytical technology; Distigmine bromide; Pharmaceutical industry; CONDUCTING POLYMER; MOLECULAR RECOGNITION; SENSORS; WATER; SPECTROMETRY; PERFORMANCE; STABILITY; CRITERIA; LIMITS;
D O I
10.1016/j.snb.2014.11.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Process Analytical Technology (PAT) is an essential step forward in the pharmaceutical industry. Real-time analyzers will provide timely data on quality properties. The aim of this work was to develop a junction between the pharmaceutical industry and recent advances in designing stable and reproducible solid-contact ion selective electrodes (SC-ISEs). Those sensors can be used as bench-top real-time analyzer for in-process tracking of the concentration of active pharmaceuticals. We have exploited the long-term stability of the chemically prepared polyaniline (PANI) nanoparticles to be applied as an ion-to-electron transducer layer between an ionophore-doped PVC membrane and glassy carbon electrodes. The inclusion of PANI nanoparticles added more stability to the electrical signal due to their excellent electronic and chemical properties. Moreover, the fast ion-to-electron transduction allows obtaining short response times and the hydrophobic behavior avoids the formation of water layers at the electrode/membrane interface. These results enabled the production of a series of SC-ISEs with improved piece-to-piece reproducibility where the potential was stable over 30 days with drift of 0.7 mV h(-1). The electrodes were utilized for distigmine bromide determination as a model pharmaceutical drug; the linear range was 1.0 x 10(-6)-1.0 x 10(-2) mol L-1 with a detection limit of 2.1 x 10(-7) mol L-1. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:14 / 21
页数:8
相关论文
共 45 条
[1]  
[Anonymous], 2002, J. Supramol. Chem., DOI DOI 10.1016/S1472-7862(03)00068-6
[2]   Ion sensors: current limits and new trends [J].
Bakker, E ;
Diamond, D ;
Lewenstam, A ;
Pretsch, E .
ANALYTICA CHIMICA ACTA, 1999, 393 (1-3) :11-18
[3]   Potentiometric sensors for trace-level analysis [J].
Bakker, E ;
Pretsch, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (03) :199-207
[4]  
Bakker E, 2001, TRAC-TREND ANAL CHEM, V20, P11, DOI 10.1016/S0165-9936(00)00056-X
[5]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[6]   Potential stability of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers [J].
Bobacka, J .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4932-4937
[7]   Conducting polymer-based solid-state ion-selective electrodes [J].
Bobacka, J .
ELECTROANALYSIS, 2006, 18 (01) :7-18
[8]   Potentiometric ion sensors based on conducting polymers [J].
Bobacka, J ;
Ivaska, A ;
Lewenstam, A .
ELECTROANALYSIS, 2003, 15 (5-6) :366-374
[9]   Potentiometric ion sensors [J].
Bobacka, Johan ;
Ivaska, Ari ;
Lewenstam, Andrzej .
CHEMICAL REVIEWS, 2008, 108 (02) :329-351
[10]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536