Bioactive surface coatings for nanoscale instruments: Effects on CNS neurons

被引:0
作者
Ignatius, MJ
Sawhney, N
Gupta, A
Thibadeau, BM
Monteiro, OR
Brown, IG
机构
[1] Univ Calif Berkeley, Dept Mol & Cell Biol, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Lawrence Berkeley Lab, Berkeley, CA 94720 USA
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1998年 / 40卷 / 02期
关键词
biocompatible; neuron growth; plasma deposition; ultrathin films; extracellular matrix; regeneration;
D O I
10.1002/(SICI)1097-4636(199805)40:2<264::AID-JBM11>3.0.CO;2-M
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A method is described for depositing onto medical instruments highly biocompatible and bioactive surface coatings that can promote and stabilize cell attachment. The coatings were made by first depositing thin films of materials, such as diamond-like carbon, or metals, including tantalum, tungsten, platinum, gold, iridium, palladium, and brass. These surfaces were further altered to either promote or inhibit cell growth and spreading by an additional over-coat of biological materials, including the extracellular matrix proteins, laminin, fibronectin, and collagen IV. The deposition technique used a metal or carbon plasma, and the important properties of film adhesion, hardness, density, and smoothness are tailored by control of the ion bombardment energy. The films are translucent enough to permit high resolution light microscopy for rapid and detailed examination of tissue response. These bioactive substrates have been tested on primary central nervous system neurons, and the growth response is excellent. Equally successful ha ve been our attempts to anchor neurons, without associated proliferation of non-neuronal cells, using coatings of poly-d-lysine. The method and the materials could have important ramifications in a number of areas of research and biotechnology, for example for chronic implantation of microelectrode arrays in the cerebral cortex for neuroprosthetic and neural monitoring application and for research on the human central nervous system. Possible applications in non-neuronal fields, such as for coronary artery stents and pace-maker electrodes, also are discussed. (C) 1998 John Wiley & Sons, Inc.
引用
收藏
页码:264 / 274
页数:11
相关论文
共 48 条
[41]   A METHOD FOR PNEUMATICALLY INSERTING AN ARRAY OF PENETRATING ELECTRODES INTO CORTICAL TISSUE [J].
ROUSCHE, PJ ;
NORMANN, RA .
ANNALS OF BIOMEDICAL ENGINEERING, 1992, 20 (04) :413-422
[42]   MULTIELECTRODE SPIRAL CUFF FOR SELECTIVE STIMULATION OF NERVE-FIBERS [J].
ROZMAN, J ;
TRLEP, M .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1992, 16 (05) :194-203
[43]   BIOCOMPATIBILITY OF SILICON-BASED ELECTRODE ARRAYS IMPLANTED IN FELINE CORTICAL TISSUE [J].
SCHMIDT, S ;
HORCH, K ;
NORMANN, R .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (11) :1393-1399
[44]  
SHEPHERD RK, 1991, BIOMATERIALS, V12, P417
[45]   SURFACE DETERMINANTS OF NEURONAL SURVIVAL AND GROWTH ON SELF-ASSEMBLED MONOLAYERS IN CULTURE [J].
STENGER, DA ;
PIKE, CJ ;
HICKMAN, JJ ;
COTMAN, CW .
BRAIN RESEARCH, 1993, 630 (1-2) :136-147
[46]   THE EFFECT OF EXTRACELLULAR-MATRIX MOLECULES ON THE INVITRO BEHAVIOR OF BOVINE ENDOTHELIAL-CELLS [J].
UNDERWOOD, PA ;
BENNETT, FA .
EXPERIMENTAL CELL RESEARCH, 1993, 205 (02) :311-319
[47]   CORONARY STENT COATINGS [J].
VANBEUSEKOM, HMM ;
SERRUYS, PW ;
VANDERGIESSEN, WJ .
CORONARY ARTERY DISEASE, 1994, 5 (07) :590-596
[48]   Multiple spike-initiation zones in single neurons revealed by voltage-sensitive dyes [J].
Zecevic, D .
NATURE, 1996, 381 (6580) :322-325