Quantitative assessment of primary mitral regurgitation using left ventricular volumes obtained with new automated three-dimensional transthoracic echocardiographic software: A comparison with 3-Tesla cardiac magnetic resonance

被引:19
作者
Levy, Franck [1 ]
Marechaux, Sylvestre [2 ]
Iacuzio, Laura [1 ]
Schouver, Elie Dan [1 ]
Castel, Anne Laure [2 ]
Toledano, Manuel [2 ]
Rusek, Stephane [1 ]
Dor, Vincent [1 ]
Tribouilloy, Christophe [3 ,4 ]
Dreyfus, Gilles [1 ]
机构
[1] Ctr Cardiothorac Monaco, 11 Bis,Ave Ostende, MC-98000 Monaco, Monaco
[2] Univ Lille Nord France, Fac Libre Med, Groupement Hop Inst Catholique Lille, F-59000 Lille, France
[3] Univ Hosp Amiens, Dept Cardiol, F-80000 Amiens, France
[4] Jules Verne Univ Picardie, INSERM U1088, F-80025 Amiens, France
关键词
3D echocardiography; Mitral regurgitation; 3-Tesla cardiac magnetic resonance; NATIVE VALVULAR REGURGITATION; ISOVELOCITY SURFACE-AREA; CHAMBER QUANTIFICATION; EUROPEAN-ASSOCIATION; AMERICAN-SOCIETY; RECOMMENDATIONS; SEVERITY;
D O I
10.1016/j.acvd.2017.10.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. - Quantitative assessment of primary mitral regurgitation (MR) using left ventricular (LV) volumes obtained with three-dimensional transthoracic echocardiography (3D TTE) recently showed encouraging results. Nevertheless, 3D TTE is not incorporated into everyday practice, as current LV chamber quantification software products are time consuming. Aims. - To investigate the accuracy and reproducibility of new automated fast 3D TTE software (HeartModel(A.I.); Philips Healthcare, Andover, MA, USA) for the quantification of LV volumes and MR severity in patients with isolated degenerative primary MR; and to compare regurgitant volume (RV) obtained with 3D TTE with a cardiac magnetic resonance (CMR) reference. Methods. - Fifty-three patients (37 men; mean age 64 +/- 12 years) with at least mild primary isolated MR, and having comprehensive 3D TTE and CMR studies within 24 h, were eligible for inclusion. MR RV was calculated using the proximal isovelocity surface area (PISA) method and the volumetric method (total LV stroke volume minus aortic stroke volume) with either CMR or 3D TTE. Results. - Inter- and intraobserver reproducibility of 3D TTE was excellent (coefficient of variation <= 10%) for LV volumes. MR RV was similar using CMR and 3D TTE (57 +/- 23 mL vs 56 28 mL; P=0.22), but was significantly higher using the PISA method (69 +/- 30 mL; P<0.05 compared with CMR and 3D TTE). The PISA method consistently overestimated MR RV compared with CMR (bias 12 +/- 21 mL), while no significant bias was found between 3D TTE and CMR (bias 2 +/- 14 mL). Concordance between echocardiography and CMR was higher using 3D TTE MR grading (intraclass correlation coefficient [ICC] = 0.89) than with PISA MR grading (ICC = 0.78). Complete agreement with CMR grading was more frequent with 3D TTE than with the PISA method (76% vs 63%). Conclusion. - 3D TTE RV assessment using the new generation of automated software correlates well with CMR in patients with isolated degenerative primary MR. (C) 2018 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:507 / 517
页数:11
相关论文
共 22 条
  • [1] [Anonymous], ARCH CARDIOVASC DIS
  • [2] Cardiac remodelling and function with primary mitral valve insufficiency studied by magnetic resonance imaging
    Aplin, Mark
    Kyhl, Kasper
    Bjerre, Jenny
    Ihlemann, Nikolaj
    Greenwood, John P.
    Plein, Sven
    Uddin, Akhlaque
    Tonder, Niels
    Host, Nis Baun
    Ahlstrom, Malin Glindvad
    Hove, Jens
    Hassager, Christian
    Iversen, Kasper
    Vejlstrup, Niels G.
    Madsen, Per Lav
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (08) : 863 - 870
  • [3] Reproducibility of Proximal Isovelocity Surface Area, Vena Contracta, and Regurgitant Jet Area for Assessment of Mitral Regurgitation Severity
    Biner, Simon
    Rafique, Asim
    Rafii, Farhad
    Tolstrup, Kirsten
    Noorani, Omid
    Shiota, Takahiro
    Gurudevan, Swaminatha
    Siegel, Robert J.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2010, 3 (03) : 235 - 243
  • [4] QUANTITATION OF MITRAL REGURGITATION BY DOPPLER ECHOCARDIOGRAPHY
    BLUMLEIN, S
    BOUCHARD, A
    SCHILLER, NB
    DAE, M
    BYRD, BF
    PORTS, T
    BOTVINICK, EH
    [J]. CIRCULATION, 1986, 74 (02) : 306 - 314
  • [5] Performance of 3-Dimensional Echocardiography in Measuring Left Ventricular Volumes and Ejection Fraction
    Dorosz, Jennifer L.
    Lezotte, Dennis C.
    Weitzenkamp, David A.
    Allen, Larry A.
    Salcedo, Ernesto E.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (20) : 1799 - 1808
  • [6] QUANTITATIVE DOPPLER ASSESSMENT OF VALVULAR REGURGITATION
    ENRIQUEZSARANO, M
    BAILEY, KR
    SEWARD, JB
    TAJIK, AJ
    KROHN, MJ
    MAYS, JM
    [J]. CIRCULATION, 1993, 87 (03) : 841 - 848
  • [7] Comparison of Accuracy of Mitral Valve Regurgitation Volume Determined by Three-Dimensional Transesophageal Echocardiography Versus Cardiac Magnetic Resonance Imaging
    Hamada, Sandra
    Altiok, Ertunc
    Frick, Michael
    Almalla, Mohammed
    Becker, Michael
    Marx, Nikolaus
    Hoffmann, Rainer
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (07) : 1015 - 1020
  • [8] Harold JG, 2014, J AM COLL CARDIOL, V63, pE57, DOI [10.1016/j.jacc.2014.02.537, 10.1016/j.jacc.2014.02.536, 10.1016/j.jtcvs.2014.05.014]
  • [9] Standardized cardiovascular magnetic resonance imaging (CMR) protocols, society for cardiovascular magnetic resonance: board of trustees task force on standardized protocols
    Kramer, Christopher M.
    Barkhausen, Jorg
    Flamm, Scott D.
    Kim, Raymond J.
    Nagel, Eike
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2008, 10 (1)
  • [10] Quantitation of mitral regurgitation with cardiac magnetic resonance imaging: a systematic review
    Krieger, Eric V.
    Lee, James
    Branch, Kelley R.
    Hamilton-Craig, Christian
    [J]. HEART, 2016, 102 (23) : 1864 - 1870