PAA polymerized downstream of a high pressure DBD plasma

被引:10
作者
Chen, Qiang [1 ]
Fu, Yabo [1 ]
Zhang, Yuefei [1 ]
Ge, Yuanjing [1 ]
机构
[1] Beijing Inst Graph Commun, Lab Plasma Phys & Mat, Beijing 102600, Peoples R China
关键词
high pressure DBD; functional group; downstream;
D O I
10.1016/j.surfcoat.2006.07.217
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The aim of this work is to develop functional materials by using a high pressure dielectric barrier discharge (DBD). As an exploration the polymers were deposited downstream of the DBD plasma. For this purpose the plasma polymer obtained from a purely organic compound, acrylic acid (AA), for the carboxyl group film as example was characterized. The properties of the coating were determined by the contact angle measurement, Fourier transform infrared (FTIR) and X-ray photoelectron spectroscopy (XPS). It revealed that the contact angle could be minimized ca. 3 degrees in high pressure plasma polymerization film, and the density of the carboxyl group was retained as high as ca. 33.3% at 2200 Pa working pressure but depending on the working pressure. (C) 2006 Published by Elsevier B.V.
引用
收藏
页码:4854 / 4857
页数:4
相关论文
共 15 条
[1]   Characterization of pulsed plasma polymerization allylamine as an adhesion layer for DNA adsorption/hybridization [J].
Chen, Q ;
Förch, R ;
Knoll, W .
CHEMISTRY OF MATERIALS, 2004, 16 (04) :614-620
[2]   A mass spectrometric and ion energy study of the continuous wave plasma polymerization of acrylic acid [J].
Haddow, DB ;
France, RM ;
Short, RD ;
Bradley, JW ;
Barton, D .
LANGMUIR, 2000, 16 (13) :5654-5660
[3]  
HADDOW DB, 2003, J BIOMED MAT RES A, V64
[4]   Integration of microfabricated needle-type glucose sensor devices with a novel thin-film Ag/AgCl electrode and plasma-polymerized thin film: mass production techniques [J].
Hiratsuka, A ;
Kojima, K ;
Suzuki, H ;
Muguruma, H ;
Ikebukuro, K ;
Karube, I .
ANALYST, 2001, 126 (05) :658-663
[5]   Mass transport behavior of electrochemical species through plasma-polymerized thin film on platinum electrode [J].
Hiratsuka, A ;
Muguruma, H ;
Nagata, R ;
Nakamura, R ;
Sato, K ;
Uchiyama, S ;
Karube, I .
JOURNAL OF MEMBRANE SCIENCE, 2000, 175 (01) :25-34
[6]  
Hiratsuka A, 1999, ELECTROANAL, V11, P1098, DOI 10.1002/(SICI)1521-4109(199911)11:15<1098::AID-ELAN1098>3.3.CO
[7]  
2-E
[8]   Amperometric glucose biosensor based on mediated electron transfer between immobilized glucose oxidase and plasma-polymerized thin film of dimethylaminomethylferrocene on sputtered gold electrode [J].
Kase, Y ;
Muguruma, H .
ANALYTICAL SCIENCES, 2004, 20 (08) :1143-1146
[9]  
Motornov M, 2003, POLYM MAT SCI ENG, V88, P264
[10]   Thin-film glucose biosensor based on plasma-polymerized film: Simple design for mass production [J].
Muguruma, H ;
Hiratsuka, A ;
Karube, I .
ANALYTICAL CHEMISTRY, 2000, 72 (11) :2671-2675