Evaluation of a Nafion coated glassy carbon electrode for determination of paraquat by differential pulse voltammetry

被引:28
作者
de Oliveira, UMF [1 ]
Lichtig, J [1 ]
Masini, JC [1 ]
机构
[1] Univ Sao Paulo, Inst Quim, BR-05513970 Sao Paulo, Brazil
关键词
paraquat determination; river water; urine; modified electrode; voltammetry; ion exchange;
D O I
10.1590/S0103-50532004000500020
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper presents an evaluation of a Nafion coated glassy carbon electrode for determination of paraquat in river water and urine by differential pulse voltammetry. The film was formed applying 4 muL of a 1% (m/v) Nafion solution, which was evaporated under an infrared light. The maximum signal to noise ratio was obtained using a 40 mmol L-1 Britton-Robinson buffer at pH 12 as supporting electrolyte. For an accumulation time of 5.0 min in open circuit, the limit of detection was 0.7 mug L-1, while the quantification limit was 1.0 mug L-1, with a linear dynamic range up to 12 mug L-1. In these conditions, a sequence of ten experiments lead to a relative standard deviation of peak current of 2.2% for a 10 mug L-1 paraquat solution. Ion pair formation in solution was the major factor of error in analysis. Despite the film to avoid adsorption of anionic species at the electrode surface, paraquat suffers strong association in solution with humic substances, proteins, clays, anionic surfactants, etc. These interactions decrease the accumulation of paraquat in the Nafion film and, as a consequence, the magnitude of the reduction peak, requiring that quantifications have to be made by standard addition. Recoveries between 87 and 106% were obtained for river waters and urine samples spiked with 1.0 and 3.0 mug L-1 paraquat.
引用
收藏
页码:735 / 741
页数:7
相关论文
共 35 条
[1]   CATHODIC STRIPPING VOLTAMMETRY OF PARAQUAT ON A CARBON PASTE ELECTRODE ELECTRODE MODIFIED WITH AMBERLITE XAD-2 RESIN [J].
ALVAREZ, E ;
SEVILLA, MT ;
PINILLA, JM ;
HERNANDEZ, L .
ANALYTICA CHIMICA ACTA, 1992, 260 (01) :19-23
[2]   ELECTROCHEMISTRY OF THE VIOLOGENS [J].
BIRD, CL ;
KUHN, AT .
CHEMICAL SOCIETY REVIEWS, 1981, 10 (01) :49-82
[3]   Nafion-coated mercury thin film electrodes for batch-injection analysis with anodic stripping voltammetry [J].
Brett, CMA ;
Brett, AMO ;
Matysik, FM ;
Matysik, S ;
Kumbhat, S .
TALANTA, 1996, 43 (11) :2015-2022
[4]   AN ION-EXCHANGE METHOD FOR DETERMINING PARAQUAT RESIDUES IN FOOD CROPS [J].
CALDERBANK, A ;
YUEN, SH .
ANALYST, 1965, 90 (1067) :99-+
[5]   On-line ion-pair solid-phase extraction-liquid chromatography-mass spectrometry for the analysis of quaternary ammonium herbicides [J].
Castro, R ;
Moyano, E ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :441-449
[6]   DETERMINATION OF PARAQUAT IN RAT-BRAIN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CORASANITI, MT ;
NISTICO, G .
JOURNAL OF CHROMATOGRAPHY, 1993, 643 (1-2) :419-425
[7]   Electroanalytical study of the paraquat herbicide in aqueous solution by square wave voltammetry using ultramicroelectrodes. [J].
de Souza, D ;
Machado, SAS .
QUIMICA NOVA, 2003, 26 (05) :644-647
[8]   QUANTITATIVE-DETERMINATION OF HERBICIDE PARAQUAT IN HUMAN-PLASMA BY GAS-CHROMATOGRAPHIC AND MASS-SPECTROMETRIC METHODS [J].
DRAFFAN, GH ;
CLARE, RA ;
DAVIES, DL ;
HAWKSWORTH, G ;
MURRAY, S ;
DAVIES, DS .
JOURNAL OF CHROMATOGRAPHY, 1977, 139 (02) :311-320
[9]   GAS-CHROMATOGRAPHIC DETERMINATION OF DIQUAT AND PARAQUAT IN CROPS [J].
HAJSLOVA, J ;
CUHRA, P ;
DAVIDEK, T ;
DAVIDEK, J .
JOURNAL OF CHROMATOGRAPHY, 1989, 479 (02) :243-250
[10]  
HODGESON JW, 1997, DETERMINATION PARAQU