Intraoperative cone-beam CT spatial priors for diffuse optical fluorescence tomography

被引:2
|
作者
Daly, M. J. [1 ,2 ]
Chan, H. [2 ]
Muhanna, N. [2 ,3 ,4 ]
Akens, M. K. [2 ,5 ,6 ]
Wilson, B. C. [2 ,6 ,7 ]
Irish, J. C. [1 ,2 ,3 ,8 ]
Jaffray, D. A. [1 ,2 ,6 ,7 ,9 ]
机构
[1] Univ Toronto, Inst Med Sci, Toronto, ON, Canada
[2] Univ Hlth Network, TECHNA Inst, Toronto, ON, Canada
[3] Univ Toronto, Dept Otolaryngol Head & Neck Surg, Toronto, ON, Canada
[4] Tel Aviv Univ, Tel Aviv Sourasky Med Ctr, Dept Otolaryngol Head & Neck & Maxillofacial Surg, Tel Aviv, Israel
[5] Univ Toronto, Dept Surg, Toronto, ON, Canada
[6] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[7] Univ Hlth Network, Princess Margaret Canc Ctr, Toronto, ON, Canada
[8] Univ Hlth Network, Dept Surg Oncol, Toronto, ON, Canada
[9] Univ Hlth Network, Dept Med Phys, Toronto, ON, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2019年 / 64卷 / 21期
基金
加拿大健康研究院;
关键词
fluorescence-guided surgery; diffuse optical tomography; surgical navigation; cone-beam CT; spatial priors; IMAGE-GUIDED INTERVENTIONS; NEAR-INFRARED TOMOGRAPHY; COMPUTED-TOMOGRAPHY; IN-VIVO; MOLECULAR TOMOGRAPHY; BREAST-CANCER; NECK-SURGERY; GUIDANCE; REAL; ARM;
D O I
10.1088/1361-6560/ab4917
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A hybrid system for intraoperative cone-beam CT (CBCT) imaging and continuous-wave fluorescence tomography (FT) has been developed using an image-guidance framework. Intraoperative CBCT images with sub-millimeter spatial resolution are acquired with a flat-panel C-Arm. Tetrahedral meshes are generated from CBCT for finite element method implementation of diffuse optical tomography (NIRFAST). Structural data from CBCT is incorporated directly into the optical reconstruction process using Laplacian-type regularization ('soft spatial priors'). Experiments were performed using an in-house optical system designed for indocyanine green (ICG) fluorescence. A dynamic non-contact geometry was achieved using a stereoscopic optical tracker for real-time localization of a laser diode and CCD camera. Source and detector positions were projected onto the boundary elements of the tissue mesh using algorithms for ray-triangle intersection and camera lens calibration. Simulation studies showed the capabilities of a soft-prior approach, even in the presence of segmentation uncertainties. Experiments with ICG targets embedded in liquid phantoms determined the improvements in the quantification of the fluorophore yield, with errors of 85% and <20% for no priors and spatial priors, respectively. Similar results were observed with the ICG target embedded in ex vivo porcine loin, with errors of 52% and 12%, respectively. A proof-of-principal animal study was performed in a VX2-tumor in vivo rabbit model using liposomal nanoparticles co-encapsulating contrast for CT (iohexol) and fluorescence (ICG) imaging. Fusion of CBCT and FT reconstructions demonstrated concurrent anatomical and functional delineations of contrast enhancement around the periphery of the buccal tumor. These developments motivate future clinical translation of the FT system into an ongoing CBCT-guided head and neck surgery trial.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Cone-beam computed tomography for trauma
    Gupta, Saurabh
    Martinson, James R.
    Ricaurte, Daniel
    Scalea, Thomas M.
    Morrison, Jonathan J.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2020, 89 (03): : E34 - E40
  • [32] Design Optimization of Spatial-Spectral Filters for Cone-Beam CT Material Decomposition
    Tivnan, Matthew
    Wang, Wenying
    Gang, Grace
    Stayman, J. Webster
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (09) : 2399 - 2413
  • [33] Safety and accuracy of spinal instrumentation surgery in a hybrid operating room with an intraoperative cone-beam computed tomography
    Bohoun, Christian A.
    Naito, Kentaro
    Yamagata, Toru
    Tamrakar, Samantha
    Ohata, Kenji
    Takami, Toshihiro
    NEUROSURGICAL REVIEW, 2019, 42 (02) : 417 - 426
  • [34] Cone-Beam Computed Tomography in Orthodontics
    Abdelkarim, Ahmad
    DENTISTRY JOURNAL, 2019, 7 (03)
  • [35] Evaluation of the spatial resolution characteristics of a cone-beam breast CT scanner
    Kwan, Alexander L. C.
    Boone, John M.
    Yang, Kai
    Huang, Shih-Ying
    MEDICAL PHYSICS, 2007, 34 (01) : 275 - 281
  • [36] Intraoperative Evaluation of Cochlear Implant Electrodes Using Mobile Cone-Beam Computed Tomography
    Yamamoto, Norio
    Okano, Takayuki
    Yamazaki, Hiroshi
    Hiraumi, Harukazu
    Sakamoto, Tatsunori
    Ito, Juichi
    Omori, Koichi
    OTOLOGY & NEUROTOLOGY, 2019, 40 (02) : 177 - 183
  • [37] Navigated percutaneous versus open pedicle screw implantation using intraoperative CT and robotic cone-beam CT imaging
    Tkatschenko, Dimitri
    Kendlbacher, Paul
    Czabanka, Marcus
    Bohner, Georg
    Vajkoczy, Peter
    Hecht, Nils
    EUROPEAN SPINE JOURNAL, 2020, 29 (04) : 803 - 812
  • [38] Beam hardening correction for a cone-beam CT system and its effect on spatial resolution
    Zhao Wei
    Fu Guo-Tao
    Sun Cui-Li
    Wang Yan-Fang
    Wei Cun-Feng
    Cao Da-Quan
    Que Jie-Min
    Tang Xiao
    Shi Rong-Jian
    Wei Long
    Yu Zhong-Qiang
    CHINESE PHYSICS C, 2011, 35 (10) : 978 - 985
  • [39] Task-driven image acquisition and reconstruction in cone-beam CT
    Gang, Grace J.
    Stayman, J. Webster
    Ehtiati, Tina
    Siewerdsen, Jeffrey H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (08): : 3129 - 3150
  • [40] RESPIRATORY MOTIONAL EFFECT ON CONE-BEAM CT IN LUNG RADIATION SURGERY
    Song, Ju-Young
    Nam, Taek-Keun
    Ahn, Sung-Ja
    Chung, Woong-Ki
    Yoon, Mee-Sun
    Nah, Byunk-Sik
    MEDICAL DOSIMETRY, 2009, 34 (02) : 117 - 125