Intraoperative cone-beam CT spatial priors for diffuse optical fluorescence tomography

被引:2
|
作者
Daly, M. J. [1 ,2 ]
Chan, H. [2 ]
Muhanna, N. [2 ,3 ,4 ]
Akens, M. K. [2 ,5 ,6 ]
Wilson, B. C. [2 ,6 ,7 ]
Irish, J. C. [1 ,2 ,3 ,8 ]
Jaffray, D. A. [1 ,2 ,6 ,7 ,9 ]
机构
[1] Univ Toronto, Inst Med Sci, Toronto, ON, Canada
[2] Univ Hlth Network, TECHNA Inst, Toronto, ON, Canada
[3] Univ Toronto, Dept Otolaryngol Head & Neck Surg, Toronto, ON, Canada
[4] Tel Aviv Univ, Tel Aviv Sourasky Med Ctr, Dept Otolaryngol Head & Neck & Maxillofacial Surg, Tel Aviv, Israel
[5] Univ Toronto, Dept Surg, Toronto, ON, Canada
[6] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[7] Univ Hlth Network, Princess Margaret Canc Ctr, Toronto, ON, Canada
[8] Univ Hlth Network, Dept Surg Oncol, Toronto, ON, Canada
[9] Univ Hlth Network, Dept Med Phys, Toronto, ON, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2019年 / 64卷 / 21期
基金
加拿大健康研究院;
关键词
fluorescence-guided surgery; diffuse optical tomography; surgical navigation; cone-beam CT; spatial priors; IMAGE-GUIDED INTERVENTIONS; NEAR-INFRARED TOMOGRAPHY; COMPUTED-TOMOGRAPHY; IN-VIVO; MOLECULAR TOMOGRAPHY; BREAST-CANCER; NECK-SURGERY; GUIDANCE; REAL; ARM;
D O I
10.1088/1361-6560/ab4917
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A hybrid system for intraoperative cone-beam CT (CBCT) imaging and continuous-wave fluorescence tomography (FT) has been developed using an image-guidance framework. Intraoperative CBCT images with sub-millimeter spatial resolution are acquired with a flat-panel C-Arm. Tetrahedral meshes are generated from CBCT for finite element method implementation of diffuse optical tomography (NIRFAST). Structural data from CBCT is incorporated directly into the optical reconstruction process using Laplacian-type regularization ('soft spatial priors'). Experiments were performed using an in-house optical system designed for indocyanine green (ICG) fluorescence. A dynamic non-contact geometry was achieved using a stereoscopic optical tracker for real-time localization of a laser diode and CCD camera. Source and detector positions were projected onto the boundary elements of the tissue mesh using algorithms for ray-triangle intersection and camera lens calibration. Simulation studies showed the capabilities of a soft-prior approach, even in the presence of segmentation uncertainties. Experiments with ICG targets embedded in liquid phantoms determined the improvements in the quantification of the fluorophore yield, with errors of 85% and <20% for no priors and spatial priors, respectively. Similar results were observed with the ICG target embedded in ex vivo porcine loin, with errors of 52% and 12%, respectively. A proof-of-principal animal study was performed in a VX2-tumor in vivo rabbit model using liposomal nanoparticles co-encapsulating contrast for CT (iohexol) and fluorescence (ICG) imaging. Fusion of CBCT and FT reconstructions demonstrated concurrent anatomical and functional delineations of contrast enhancement around the periphery of the buccal tumor. These developments motivate future clinical translation of the FT system into an ongoing CBCT-guided head and neck surgery trial.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] A Surgical Navigation System for Non- Contact Diffuse Optical Tomography and Intraoperative Cone- Beam CT
    Daly, Michael J.
    Muhanna, Nidal
    Chan, Harley
    Wilson, Brian C.
    Irish, Jonathan C.
    Jaffray, David A.
    MULTIMODAL BIOMEDICAL IMAGING IX, 2014, 8937
  • [2] Fusion of Intraoperative Cone-Beam CT and Endoscopic Video for Image-Guided Procedures
    Daly, M. J.
    Chan, H.
    Prisman, E.
    Vescan, A.
    Nithiananthan, S.
    Qiu, J.
    Weersink, R.
    Irish, J. C.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [3] Clinical Implementation of Intraoperative Cone-Beam CT in Head and Neck Surgery
    Daly, M. J.
    Chan, H.
    Nithiananthan, S.
    Qiu, J.
    Barker, E.
    Bachar, G.
    Dixon, B. J.
    Irish, J. C.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [4] VISUALIZATION OF ANTERIOR SKULL BASE DEFECTS WITH INTRAOPERATIVE CONE-BEAM CT
    Bachar, Gideon
    Barker, Emma
    Chan, Harley
    Daly, Michael J.
    Nithiananthan, Sajendra
    Vescan, Al
    Irish, Jonathan C.
    Siewerdsen, Jeffrey H.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2010, 32 (04): : 504 - 512
  • [5] Non-Contact Fluorescence Tomography with a Cone-Beam CT Surgical Guidance System
    Daly, Michael J.
    Chan, Harley H. L.
    Muhanna, Nidal
    Akens, Margarete K.
    Wilson, Brian C.
    Irish, Jonathan C.
    Jaffray, David A.
    MOLECULAR-GUIDED SURGERY: MOLECULES, DEVICES, AND APPLICATIONS V, 2019, 10862
  • [6] Automatic intraoperative stitching of nonoverlapping cone-beam CT acquisitions
    Fotouhi, Javad
    Fuerst, Bernhard
    Unberath, Mathias
    Reichenstein, Stefan
    Lee, Sing Chun
    Johnson, Alex A.
    Osgood, Greg M.
    Armand, Mehran
    Navab, Nassir
    MEDICAL PHYSICS, 2018, 45 (06) : 2463 - 2475
  • [7] Workflow and performance of intraoperative CT, cone-beam CT, and robotic cone-beam CT for spinal navigation in 503 consecutive patients
    Kendlbacher, Paul
    Tkatschenko, Dimitri
    Czabanka, Marcus
    Bayerl, Simon
    Bohner, Georg
    Woitzik, Johannes
    Vajkoczy, Peter
    Hecht, Nils
    NEUROSURGICAL FOCUS, 2022, 52 (01)
  • [8] TREK: an integrated system architecture for intraoperative cone-beam CT-guided surgery
    Uneri, A.
    Schafer, S.
    Mirota, D. J.
    Nithiananthan, S.
    Otake, Y.
    Taylor, R. H.
    Siewerdsen, J. H.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (01) : 159 - 173
  • [9] Demons deformable registration of CT and cone-beam CT using an iterative intensity matching approach
    Nithiananthan, Sajendra
    Schafer, Sebastian
    Uneri, Ali
    Mirota, Daniel J.
    Stayman, J. Webster
    Zbijewski, Wojciech
    Brock, Kristy K.
    Daly, Michael J.
    Chan, Harley
    Irish, Jonathan C.
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2011, 38 (04) : 1785 - 1798
  • [10] Intraoperative use of cone-beam computed tomography in a cadaveric ossified cochlea model
    Barker, Emma
    Trimble, Keith
    Chan, Harley
    Ramsden, James
    Nithiananthan, Sajendra
    James, Adrian
    Bachar, Gideon
    Daly, Mike
    Irish, Jonathan
    Siewerdsen, Jeff
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2009, 140 (05) : 697 - 702