Comparison of ion plasma, vaporized hydrogen peroxide, and 100% ethylene oxide sterilizers to the 12/88 ethylene oxide gas sterilizer

被引:78
作者
Alfa, MJ
DeGagne, P
Olson, N
Puchalski, T
机构
关键词
D O I
10.1086/647252
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
OBJECTIVE: The performance of a standard gas sterilizer, which uses a mixture of 12% ethylene oxide (EtO) and 88% chlorofluorocarbon as the sterilizing gas (12/88), was compared to selected gas, ion plasma, and vaporized hydrogen peroxide (H2O2) sterilizers that do not use chlorofluorocarbons. The effect of serum and salt an sterilizer performance was evaluated. DESIGN: Test carriers (porcelain and stainless steel penicylinders, or 125-cm lengths of plastic tubing [internal diameter of 3.2 mm]) were inoculated with Escherichia coli, Enterococcus faecalis, Pseudomonas aeruginosa, Mycobacterium chelonei, Bacillus stearothermophilus spores, Bacillus subtilis spores, and Bacillus circulans spores and then subjected to sterilization using 12/88, 100% EtO, ion plasma, or vaporized H2O2. The bacterial inoculum was prepared with and without 10% serum and 0.65% salt, and the residual bacterial load after sterilization as determined using viable counts. RESULT: All of the sterilizers tested effected a six-log(50) reduction of the bacterial inoculum on penicylinders, unless 10% serum and 0.65% salt were present, in which case the 100% EtO, vaporized H2O2, and ion plasma sterilizers were not as effective as the 12/88 sterilizer. None of the sterilizers could eradicate 10(6) CFU of all of the bacteria in 10% serum and 0.65% salt when inoculated inside a narrow lumen. CONCLUSIONS: The margin of safety for the 100% EtO, vaporized H2O2, and ion plasma sterilizers is less than that of the 12/88 sterilizer. The inability of all sterilizers, including the 12/88, to kill organisms in narrow lumens reliably when serum and salt were present raises concern about the current practice of gas sterilization of flexible endoscopes.
引用
收藏
页码:92 / 100
页数:9
相关论文
共 9 条
  • [1] IN-HOSPITAL EVALUATION OF ORTHOPHTHALALDEHYDE AS A HIGH-LEVEL DISINFECTANT FOR FLEXIBLE ENDOSCOPES
    ALFA, MJ
    SITTER, DL
    [J]. JOURNAL OF HOSPITAL INFECTION, 1994, 26 (01) : 15 - 26
  • [2] Caputo R A, 1992, J Healthc Mater Manage, V10, P48
  • [3] *CONS EV TECHN SAN, 1995, INF B, pR7
  • [4] HENSYL WR, 1989, BERGEYS MANUAL SYSTE, V4
  • [5] HOLLER C, 1993, ZBL HYG UMWELTMED, V194, P380
  • [6] JORDY A, 1993, ZENTR STERIL, V1, P45
  • [7] LYNCH MM, 1995, SURGICAL SERVICES MA, V1, P24
  • [8] MECKE P, 1992, HYGIENE MED, V17, P536
  • [9] Wilson R, 1994, J Healthc Mater Manage, V12, P37