Effects of heat exchange fluid characteristics and pipe configuration on the ultimate bearing capacity of energy piles

被引:15
作者
Garakani, Amir Akbari [1 ]
Jozani, Sahar Mokhtari [2 ]
Tari, Pooyan Hashemi [3 ]
Heidari, Bahareh [2 ]
机构
[1] Niroo Res Inst, Power Ind Struct Res Dept, Room 403-4th Floor,End Dadman Blvd, Tehran 1468617151, Iran
[2] Univ Sci & Culture, Dept Civil Engn, Tehran, Iran
[3] Shahid Beheshti Univ, Dept Mech & Energy Syst Engn, Tehran, Iran
关键词
Energy pile; Ultimate bearing capacity; Numerical modeling; Fluid characteristics; Pipe configuration; THERMAL PERFORMANCE; THERMOMECHANICAL BEHAVIOR; DIFFERENT DESIGN; CONSTRUCTABILITY; FOUNDATIONS; TEMPERATURE; SIMULATION; EFFICIENCY;
D O I
10.1016/j.energy.2022.123583
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper examines the ultimate bearing capacity of energy piles in sandy and clayey soils by conducting numerical modeling under different thermal loads, fluid-pipe configurations and fluid characteristics. Accordingly, U and W-shaped fluid-pipes with different diameters were simulated using ANSYS-FLUENT software, under different inlet flow rates, fluid temperatures and ground temperatures. Moreover, a semi-empirical analytical solution is proposed for predicting the outlet temperature for different pipe configurations. Then, the energy piles were modeled using ABAQUS FE-software, and the effect of temperature distribution in U, double-U and W-shaped pipes on the ultimate bearing capacity was studied, in heating/cooling conditions. Both numerical simulations and the analytical solution were validated against experimental data. Results showed that under constant flow rate, initial inlet temperature and pipe diameter, the differences between the inlet and outlet temperature of the heat exchange fluid in the U-shaped pipes was less than that obtained for the W-shaped pipes. Also, for constant inlet temperature and pipe diameter, the temperature difference decreased when the inlet flow rate increased. It was found that under constant thermal loading conditions, the changes in the ultimate bearing capacity were higher in piles with double U-shaped pipes, followed by U-shaped pipes, and lowest for W-shaped pipes.(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页数:18
相关论文
共 63 条
[11]   Analysis on the transient heat transfer process inside and outside the borehole for a vertical U-tube ground heat exchanger under short-term heat storage [J].
Dai, L. H. ;
Shang, Y. ;
Li, X. L. ;
Li, S. F. .
RENEWABLE ENERGY, 2016, 87 :1121-1129
[12]  
Das B.M., 2021, PRINCIPLES GEOTECHNI
[13]  
Desai Y.M., 2011, Finite Element Method with Application in Engineering
[14]   Axial compressive capacity of helical piles from field tests and numerical study [J].
Elsherbiny, Zeyad H. ;
El Naggar, M. Hesham .
CANADIAN GEOTECHNICAL JOURNAL, 2013, 50 (12) :1191-1203
[15]  
EPA, 1993, EPA 430-R-93-004
[16]   Axial Performance of Helical Tapered Piles in Sand [J].
Fahmy A. ;
El Naggar M.H. .
Geotechnical and Geological Engineering, 2017, 35 (4) :1549-1576
[17]   Experimental and Numerical Study on the Behavior of Energy Piles Subjected to Thermal Cycles [J].
Fei, Kang ;
Dai, Di .
ADVANCES IN CIVIL ENGINEERING, 2018, 2018
[18]  
Fellenius B.H., 1989, TRANSPORTATION RES B, P75
[19]   ASSESSMENT STUDY OF k-ε TURBULENCE MODELS AND NEAR-WALL MODELING FOR STEADY STATE SWIRLING FLOW ANALYSIS IN DRAFT TUBE USING FLUENT [J].
Galvan, Sergio ;
Reggio, Marcelo ;
Guibault, Francois .
ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2011, 5 (04) :459-478
[20]   Numerical and experimental assessment of thermal performance of vertical energy piles: An application [J].
Gao, Jun ;
Zhang, Xu ;
Liu, Jun ;
Li, Kuishan ;
Yang, He .
APPLIED ENERGY, 2008, 85 (10) :901-910