HIGH-SHEAR GRANULATION PROCESS: INFLUENCE OF PROCESSING PARAMETERS ON CRITICAL QUALITY ATTRIBUTES OF ACETAMINOPHEN GRANULES AND TABLETS USING DESIGN OF EXPERIMENT APPROACH

被引:0
作者
Fayed, Mohamed H. [1 ]
Abdel-Rahman, Sayed I. [2 ]
Alanazi, Fars K. [3 ]
Ahmed, Mahrous O. [2 ]
Tawfeek, Hesham M. [2 ]
Al-Shedfat, Ramadan I. [1 ]
机构
[1] Prince Sattam Bin Abdulaziz Univ, Dept Pharmaceut, Coll Pharm, Al Kharj, Saudi Arabia
[2] Assiut Univ, Fac Pharm, Dept Ind Pharm, Assiut, Egypt
[3] King Saud Univ, Dept Pharmaceut, Kayyali Chair Pharmaceut Ind, Coll Pharm, Riyadh, Saudi Arabia
来源
ACTA POLONIAE PHARMACEUTICA | 2017年 / 74卷 / 01期
关键词
high shear granulation; design of experiment; process variables; granules; tablets; acetaminophen; WET GRANULATION; MICROCRYSTALLINE CELLULOSE; FACTORIAL DESIGN; BED GRANULATION; FLUIDIZED-BED; FORMULATION; COMPRESSIBILITY; METHODOLOGY; PRODUCT; POWDER;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Application of quality by design (QbD) in high shear granulation process is critical and need to recognize the correlation between the granulation process parameters and the properties of intermediate (granules) and corresponding final product (tablets). The present work examined the influence of water amount (X1) and wet massing time (X2) as independent process variables on the critical quality attributes of granules and corresponding tablets using design of experiment (DoE) technique. A two factor, three level (32) full factorial design was performed; each of these variables was investigated at three levels to characterize their strength and interaction. The dried granules have been analyzed for their size distribution, density and flow pattern. Additionally, the produced tablets have been investigated for weight uniformity, crushing strength, friability and percent capping, disintegration time and drug dissolution. Statistically significant impact (p < 0.05) of water amount was identified for granule growth, percent fines and distribution width and flow behavior. Granule density and compressibility were found to be significantly influenced (p < 0.05) by the two operating conditions. Also, water amount has significant effect (p < 0.05) on tablet weight uniformity, friability and percent capping. Moreover, tablet disintegration time and drug dissolution appears to be significantly influenced (p < 0.05) by the two process variables. On the other hand, the relationship of process parameters with critical quality attributes of granule and final product tablet was identified and correlated. Ultimately, a judicious selection of process parameters in high shear granulation process will allow providing product of desirable quality.
引用
收藏
页码:235 / 248
页数:14
相关论文
共 28 条
  • [1] [Anonymous], 2015, USP 38NF 33 US PHARM
  • [2] Mechanistic basis for the effects of process parameters on quality attributes in high shear wet granulation
    Badawy, Sherif I. F.
    Narang, Ajit S.
    LaMarche, Keirnan
    Subramanian, Ganeshkumar
    Varia, Sailesh A.
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2012, 439 (1-2) : 324 - 333
  • [3] Effect of process parameters on compressibility of granulation manufactured in a high-shear mixer
    Badawy, SIF
    Menning, MM
    Gorko, MA
    Gilbert, DL
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2000, 198 (01) : 51 - 61
  • [4] Buhler V., 2005, Polyvinylpyrrolidone Excipients for Pharmaceuticals
  • [5] A new methodology for high drug loading wet granulation formulation development
    Cai, Lixia
    Farber, Leon
    Zhang, Dina
    Li, Feng
    Farabaugh, Julianne
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2013, 441 (1-2) : 790 - 800
  • [6] Formulation, release characteristics and bioavailability of novel monolithic hydroxypropylmethylcellulose matrix tablets containing acetaminophen
    Cao, QR
    Choi, YW
    Cui, JH
    Lee, BJ
    [J]. JOURNAL OF CONTROLLED RELEASE, 2005, 108 (2-3) : 351 - 361
  • [7] Prospective validation of high-shear wet granulation process by wet granule sieving method .2. Utility of wet granule sieving method
    Emori, H
    Sakuraba, Y
    Takahashi, K
    Nishihata, T
    Mayumi, T
    [J]. DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1997, 23 (02) : 203 - 215
  • [8] Switch from single pot to multiphase high shear wet granulation process, influence of the volume of granulation liquid in a pilot scale study
    Giry, K.
    Viana, M.
    Genty, M.
    Wuethrich, P.
    Chulia, D.
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2009, 48 (08) : 1293 - 1301
  • [9] Improvement of flow and bulk density of pharmaceutical powders using surface modification
    Jallo, Laila J.
    Ghoroi, Chinmay
    Gurumurthy, Lakxmi
    Patel, Utsav
    Dave, Rajesh N.
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2012, 423 (02) : 213 - 225
  • [10] The effect of shape and porosity on the compression behaviour and tablet forming ability of granular materials formed from microcrystalline cellulose
    Johansson, B
    Alderborn, G
    [J]. EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2001, 52 (03) : 347 - 357