Energy and exergy analysis of the turbo-generators and steam turbine for the main feed water pump drive on LNG carrier

被引:51
|
作者
Mrzljak, Vedran [1 ]
Poljak, Igor [2 ]
Mrakovcic, Tomislav [1 ]
机构
[1] Univ Rijeka, Fac Engn, Vukovarska 58, Rijeka 51000, Croatia
[2] Rozici 4-3, Kostrena 51221, Croatia
关键词
Turbo-generator; Main feed water pump; Energy efficiency; Exergy efficiency; Exergy destruction; ARTIFICIAL NEURAL-NETWORK; POWER-PLANT; COMBINED HEAT; EXERGOECONOMIC ANALYSIS; CYCLE; OPTIMIZATION; EFFICIENCY; SYSTEMS; UNCERTAINTIES; TEMPERATURE;
D O I
10.1016/j.enconman.2017.03.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
Nowadays, marine propulsion systems are mainly based on internal combustion diesel engines. Despite this fact, a number of LNG carriers have steam propulsion plants. In such plants, steam turbines are used not only for ship propulsion, but also for electrical power generation and main feed water pump drive. Marine turbo-generators and steam turbine for the main feed water pump drive were investigated on the analyzed LNG carrier with steam propulsion plant. The measurements of various operating parameters were performed and obtained data were used for energy and exergy analysis. All the measurements and calculations were performed during the ship acceleration. The analysis shows that the energy and exergy efficiencies of both analyzed low-power turbines vary between 46% and 62% what is significantly lower in comparison with the high-power steam turbines. The ambient temperature has a low impact on exergy efficiency of analyzed turbines (change in ambient temperature for 10 degrees C causes less than 1% change in exergy efficiency). The highest exergy efficiencies were achieved at the lowest observed ambient temperature. Also, the highest efficiencies were achieved at 71.5% of maximum developed turbogenerator power while the highest efficiencies of steam turbine for the main feed water pump drive were achieved at maximum turbine developed power. Replacing the existing steam turbine for the main feed water pump drive with an electric motor would increase the turbo-generator energy and exergy efficiencies for at least 1-3% in all analyzed operating points. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:307 / 323
页数:17
相关论文
共 4 条
  • [1] Energy Analysis of Main Propulsion Steam Turbine from Conventional LNG Carrier at Three Different Loads
    Mrzljak, Vedran
    Poljak, Igor
    NASE MORE, 2019, 66 (01): : 10 - 18
  • [2] The efficiency analysis of steam turbine-driven feed water pump
    Liu Ming-fu
    Lu Gai-lin
    FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY III, PTS 1-3, 2013, 401 : 312 - 315
  • [3] Energy Saving in Water Distribution Network through Pump as Turbine Generators: Economic and Environmental Analysis
    De Marchis, Mauro
    Milici, Barbara
    Volpe, Roberto
    Messineo, Antonio
    ENERGIES, 2016, 9 (11)
  • [4] Analysis of the Energy Efficiency of Different Methods of Adding Make-up Feed Water in the Steam Turbine Cycle CHPP
    Shempelev, A. G.
    PROBLEMELE ENERGETICII REGIONALE, 2020, (04): : 69 - 77