Measurement of segmental cervical multifidus contraction by ultrasonography in asymptomatic adults

被引:70
作者
Lee, Jo-Ping
Tseng, Wen-Yih I.
Shau, Yio-Wha
Wang, Chung-Li
Wang, Hsing-Kuo
Wang, Shwu-Fen
机构
[1] Natl Taiwan Univ, Sch Phys Therapy, Coll Med, Taipei 100, Taiwan
[2] Natl Taiwan Univ, Grad Inst Phys Therapy, Coll Med, Taipei 100, Taiwan
[3] Natl Taiwan Univ, Ctr Optoelect Biomed, Coll Med, Taipei 100, Taiwan
[4] Natl Taiwan Univ, Inst Appl Mech, Coll Engn, Taipei 100, Taiwan
[5] Natl Taiwan Univ Hosp, Dept Orthoped Surg, Taipei, Taiwan
关键词
ultrasonography; cervical multifidus; validity; reliability;
D O I
10.1016/j.math.2006.07.008
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
The deep muscles that play significant roles in maintaining segmental stability have been measured using ultrasonography (US). However, few studies have been carried out to determine the reliability and validity of US for measuring the cervical multifidus during contraction. The aims of this investigation were to evaluate the reliability of the dimensions of the cervical multifidus as measured using US and compare the US measurements with those determined with magnetic resonance imaging (MRI), the gold standard. Ten asymptomatic adult subjects (age, 28.5 +/- 3.5 years) participated in testing-retesting of muscle dimensions at rest and during isometric head extension with the cranio-cervical spine maintained in a flexed position against individual maximum resistance. Ten asymptomatic adult subjects (age, 28.1 +/- 4.1 years) participated in testing to compare US and MRI measurements of the thickness, width, area, and shape ratio of the cervical multifidus at the C4, C5, and C6 levels. US measurements of muscle thickness at the C4, C5, and C6 levels at rest were 0.67 +/- 0.14, 0.70 +/- 0.20 and 0.73 +/- 0.09 cm, respectively; the corresponding measurements as determined by MRI were 0.70 +/- 0.12, 0.67 +/- 0.15 and 0.70 +/- 0.06cm. The within-subject coefficient of variation (CV,) for thickness at rest and during contraction was less than 10%, indicating acceptable reliability. US measurement of thickness had better reliability and validity. The range of limit of agreement for muscle thickness at the C4, C5, and C6 levels was -0.20 to 0.20 cm, and the range of R-2 was 0.42-0.64. The thickness of the cervical multifidus muscle increased significantly during contraction (1. 13 +/- 0.20, 1.19 +/- 0.20 and 1. 17 +/- 0.12 cm for the C4, C5, and C6 levels, P < 0.05). However, no significant differences were noted among the three levels. The results indicate that US can detect changes in segmental cervical multifidus during contraction. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:286 / 294
页数:9
相关论文
共 31 条
[1]   Morphology, architecture, and biomechanics of human cervical multifidus [J].
Anderson, JS ;
Hsu, AW ;
Vasavada, AN .
SPINE, 2005, 30 (04) :E86-E91
[2]  
Campbell WW, 1998, MUSCLE NERVE, V21, P1350, DOI 10.1002/(SICI)1097-4598(199810)21:10<1350::AID-MUS21>3.0.CO
[3]  
2-4
[4]   The Saskatchewan Health and Back Pain Survey -: The prevalence of neck pain and related disability in Saskatchewan adults [J].
Côté, P ;
Cassidy, JD ;
Carroll, L .
SPINE, 1998, 23 (15) :1689-1698
[5]  
Côté P, 2000, SPINE, V25, P1109
[6]   Measurement of human muscle volume using ultrasonography [J].
Esformes, JI ;
Narici, MV ;
Maganaris, CN .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2002, 87 (01) :90-92
[7]  
GERHARDT P, 1991, ALTAS ANATOMIC CORRE
[8]   Accuracy of abnormal paraspinal muscle findings on contrast-enhanced MR images as indirect signs of unilateral cervical root-avulsion injury [J].
Hayashi, N ;
Masumoto, T ;
Abe, O ;
Aoki, S ;
Ohtomo, K ;
Tajiri, Y .
RADIOLOGY, 2002, 223 (02) :397-402
[9]  
HIDES J A, 1992, Physiotherapy Theory and Practice, V8, P19, DOI 10.3109/09593989209108076
[10]   MAGNETIC-RESONANCE-IMAGING AND ULTRASONOGRAPHY OF THE LUMBAR MULTIFIDUS MUSCLE - COMPARISON OF 2 DIFFERENT MODALITIES [J].
HIDES, JA ;
RICHARDSON, CA ;
JULL, GA .
SPINE, 1995, 20 (01) :54-58