Transcatheter Tricuspid Valve Replacement With the EVOQUE System 1-Year Outcomes of a Multicenter, First-in-Human Experience

被引:68
|
作者
Webb, John G. [1 ]
Chuang, Anthony [1 ]
Meier, David [1 ]
von Bardeleben, Ralph Stephan [2 ]
Kodali, Susheel K. [3 ]
Smith, Robert L. [4 ]
Hausleiter, Joerg [5 ,6 ]
Ong, Geraldine [7 ]
Boone, Robert [1 ]
Ruf, Tobias [2 ]
George, Isaac [3 ]
Szerlip, Molly [4 ]
Naebauer, Michael [5 ,6 ]
Ali, Faeez M. [7 ]
Moss, Robert [1 ]
Kreidel, Felix [2 ]
Bapat, Vinayak [4 ]
Schnitzler, Katharina [5 ,6 ]
Ye, Jian [1 ]
Wild, Mirjam [5 ,6 ]
Akodad, Mariama [5 ,6 ]
Deva, Djeven P. [1 ]
Chatfield, Andrew G. [7 ]
Mack, Michael J. [1 ]
Grayburn, Paul A. [4 ]
Peterson, Mark D. [7 ]
Makkar, Raj [8 ]
Leon, Martin B. [3 ]
Hahn, Rebecca T. [3 ]
Fam, Neil P. [7 ]
机构
[1] St Pauls Hosp, 1081 Burrard St, Vancouver, BC V6Z 1Y6, Canada
[2] Johannes Gutenberg Univ Mainz, Univ Med Mainz, Zentrum Kardiol, Mainz, Germany
[3] Columbia Univ, Irving Med Ctr, New York Presbyterian Hosp, Struct Heart & Vasc Ctr, New York, NY USA
[4] Baylor Scott & White Heart & Vasc Hosp, Dallas, TX USA
[5] Klinikum Univ Munchen, Med Klin & Poliklin 1, Munich, Germany
[6] DZHK German Ctr Cardiovasc Res, Partner Site Munich Heart Alliance, Munich, Germany
[7] Univ Toronto, St Michaels Hosp, Toronto, ON, Canada
[8] Cedars Sinai Med Ctr, Los Angeles, CA 90048 USA
基金
瑞士国家科学基金会;
关键词
EVOQUE; transcatheter tricuspid valve replacement; tricuspid regurgitation; tricuspid valve; TO-EDGE REPAIR; REGURGITATION; IMPACT;
D O I
10.1016/j.jcin.2022.01.280
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The aim of this study was to report the midterm outcomes at 1 year in the expanded first-in-human experience with the transfemoral EVOQUE system (Edwards Lifesciences) for tricuspid regurgitation (TR). BACKGROUND Untreated TR is associated with excess mortality and morbidity. The first-in-human experience with the EVOQUE tricuspid valve replacement system reported favorable 30-day outcomes with no mortality in a compassionate use population. METHODS Twenty-seven patients with severe TR were treated with the EVOQUE system in a compassionate use experience at 7 centers between May 2019 and July 2020. All patients had clinical right-sided heart failure (HF) and were deemed inoperable and unsuitable for transcatheter edge-to-edge repair by the institutional heart teams. The clinical outcomes collected included all-cause mortality, symptom status, TR severity, HF hospitalization, and major adverse cardiovascular events. RESULTS At baseline, all patients (age: 77 +/- 8 years, 89% female) were at high surgical risk (mean Society of Thoracic Surgeons score: 8.6% +/- 5.5%), with 89% New York Heart Association functional class III/IV. TR was predominantly functional in etiology (19/27, 70%). At 1 year, mortality was 7% (2/27), 70% of patients were New York Heart Association functional class I/II, and 96% and 87% of patients had a TR grade <= 2+ and <= 1+, respectively. Between 30 days and 1 year, 2 patients experienced HF hospitalizations, and 1 patient required a new pacemaker implantation. CONCLUSIONS In this early, compassionate use experience, the transfemoral transcatheter EVOQUE tricuspid valve replacement system demonstrated durable efficacy, persistent improvement in symptom status, and low rates of mortality and HF hospitalizations at a 1-year follow-up. Further studies are underway to validate its efficacy. (C) 2022 by the American College of Cardiology Foundation.
引用
收藏
页码:481 / 491
页数:11
相关论文
共 50 条
  • [21] Transcatheter Laceration of Aortic Leaflets to Prevent Coronary Obstruction During Transcatheter Aortic Valve Replacement Concept to First-in-Human
    Khan, Jaffar M.
    Dvir, Danny
    Greenbaum, Adam B.
    Babaliaros, Vasilis C.
    Rogers, Toby
    Aldea, Gabriel
    Reisman, Mark
    Mackensen, G. Burkhard
    Eng, Marvin H. K.
    Paone, Gaetano
    Wang, Dee Dee
    Guyton, Robert A.
    Devireddy, Chandan M.
    Schenke, William H.
    Lederman, Robert J.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (07) : 677 - 689
  • [22] Clinical risk model for predicting 1-year mortality after transcatheter aortic valve replacement
    Yamamoto, Masanori
    Otsuka, Toshiaki
    Shimura, Tetsuro
    Yamaguchi, Ryo
    Adachi, Yuya
    Kagase, Ai
    Tokuda, Takahiro
    Yashima, Fumiaki
    Watanabe, Yusuke
    Tada, Norio
    Naganuma, Toru
    Araki, Motoharu
    Yamanaka, Futoshi
    Mizutani, Kazuki
    Tabata, Minoru
    Watanabe, Shun
    Sato, Yasunori
    Ueno, Hiroshi
    Takagi, Kensuke
    Higashimori, Akihiro
    Shirai, Shinichi
    Hayashida, Kentaro
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 97 (04) : E544 - E551
  • [23] Tricuspid Transcatheter Edge-to-Edge Repair for Severe Tricuspid Regurgitation 1-Year Outcomes From the TRILUMINATE Randomized Cohort
    Tang, Gilbert H. L.
    Hahn, Rebecca T.
    Whisenant, Brian K.
    Hamid, Nadira
    Naik, Hursh
    Makkar, Raj R.
    Tadros, Peter
    Price, Matthew J.
    Singh, Gagan D.
    Fam, Neil P.
    Kar, Saibal
    Mehta, Shamir R.
    Bae, Richard
    Sekaran, Nishant K.
    Warner, Travis
    Makar, Moody
    Zorn, George
    Benza, Raymond
    Jorde, Ulrich P.
    Mccarthy, Patrick M.
    Thourani, Vinod H.
    Ren, Qian
    Trusty, Phillip M.
    Sorajja, Paul
    Adams, David H.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2025, 85 (03) : 235 - 246
  • [24] Early Effects of Transcatheter Edge-to-Edge Leaflet Repair for Tricuspid Regurgitation: First-in-Human Experience with Computed Tomography
    Lopes, Bernardo B. C.
    Sorajja, Paul
    Hashimoto, Go
    Fukui, Miho
    Du, Yu
    Ahmed, Aisha
    Lesser, John R.
    Cavalcante, Joao L.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2021, 15 (02) : E12 - E14
  • [25] First-in-human Results of the Novel Transcatheter Mitral Valve Repair System for Severe Mitral Regurgitation
    Lu, Zhi-Nan
    Ke, Yutong
    Bian, Yingnan
    He, Jing
    Wu, Wenhui
    Liu, Xinmin
    Li, Yang
    Liu, Ran
    Luo, Taiyang
    Guo, Xunan
    Song, Guangyuan
    CARDIOLOGY DISCOVERY, 2024, 4 (02): : 148 - 159
  • [26] First-in-human study of the K-Clip™ transcatheter annular repair system for severe functional tricuspid regurgitation
    Zhang, Xiaochun
    Jin, Qinchun
    Pan, Wenzhi
    Li, Wei
    Guo, Yingqiang
    Ma, Genshan
    Pan, Cuizhen
    Chen, Shasha
    Zhang, Yuan
    Zhang, Lei
    Li, Mingfei
    Hou, Shiqiang
    Lam, Yat-Yin
    Modine, Thomas
    Lee, Alex Pui-Wai
    Qian, Juying
    Zhou, Daxin
    Ge, Junbo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2023, 390
  • [27] Early Safety and Performance of the Premounted Transcatheter Aortic Valve System 30-Day Outcomes of the First-in-Human VIVA Feasibility Study
    Briedis, Kasparas
    Aldujeli, Ali
    Zaliunas, Remigijus
    Benetis, Rimantas
    AMERICAN JOURNAL OF CARDIOLOGY, 2023, 204 : 302 - 311
  • [28] Mitral Valve Transcatheter Edge-to-Edge Repair 1-Year Outcomes From the MiCLASP Study
    Lurz, Philipp
    Schmitz, Thomas
    Geisler, Tobias
    Hausleiter, Joerg
    Eitel, Ingo
    Rudolph, Volker
    Lubos, Edith
    von Bardeleben, Ralph Stephan
    Brambilla, Nedy
    De Marco, Federico
    Berti, Sergio
    Nef, Holger
    Linke, Axel
    Hengstenberg, Christian
    Baldus, Stephan
    Spargias, Konstantinos
    Denti, Paolo
    Nickenig, Georg
    Moellmann, Helge
    Rottbauer, Wolfgang
    Praz, Fabien
    Butter, Christian
    Reinthaler, Markus
    Van Mieghem, Nicolas M.
    Sherif, Mohammad
    Swaans, Martin
    Witkowski, Adam
    Buch, Mamta
    Seidler, Tim
    Iniguez, Andres
    Thiele, Holger
    Eissmann, Mareike
    Schreieck, Juergen
    Naebauer, Michael
    Marcoff, Leo
    Koulogiannis, Konstantinos
    Rassaf, Tienush
    Luedike, Peter
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (07) : 890 - 903
  • [29] Long-Term Outcomes of Percutaneous Paravalvular Regurgitation Closure After Transcatheter Aortic Valve Replacement A Multicenter Experience
    Saia, Francesco
    Martinez, Claudia
    Gafoor, Sameer
    Singh, Vikas
    Ciuca, Cristina
    Hofmann, Ilona
    Marrozzini, Cinzia
    Tan, John
    Webb, John
    Sievert, Horst
    Marzocchi, Antonio
    O'Neill, William W.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (05) : 681 - 688
  • [30] 1-Year Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expandable Valves Results From the CHOICE Randomized Clinical Trial
    Abdel-Wahab, Mohamed
    Neumann, Franz-Josef
    Mehilli, Julinda
    Frerker, Christian
    Richardt, Doreen
    Landt, Martin
    Jose, John
    Toelg, Ralph
    Kuck, Karl-Heinz
    Massberg, Steffen
    Robinson, Derek R.
    El-Mawardy, Mohamed
    Richardt, Gert
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (07) : 791 - 800